Reliability of running gait variability measures calculated from inertial measurement units

被引:0
|
作者
Jones, Ben. D. M. [1 ,2 ]
Wheat, Jon [3 ]
Middleton, Kane [2 ]
Carey, David L. [2 ]
Heller, Ben [1 ]
机构
[1] Sheffield Hallam Univ, Sport & Phys Act Res Ctr, Olymp Legacy Pk,2 Old Hall Rd, Sheffield S9 3TY, England
[2] La Trobe Univ, Sch Allied Hlth Human Serv & Sport, Sport Performance & Nutr Res Grp, Melbourne, Vic 3086, Australia
[3] Nottingham Trent Univ, Sport & Human Performance Enhancement Res Ctr, Clifton Campus, Nottingham NG11 8NS, England
关键词
Running gait; Complexity; Regularity; Between-day reliability; Inertial measurement unit; LONG-RANGE CORRELATIONS; TIME; RUNNERS; BALANCE; INJURY; ADULTS; SPEED; STYLE; RUN;
D O I
10.1016/j.jbiomech.2025.112515
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Changes to the variability within biomechanical signals may reflect a change in the health of the human system. However, for running gait variability measures calculated from wearable device data, it is unknown whether a between-day difference reflects a shift in system dynamics reflective of a change in human health or is a result of poor between-day reliability of the measurement device or the biomechanical signal. This study investigated the reliability of stride time and sacral acceleration variability measures calculated from inertial measurement units (IMUs). Nineteen runners completed six treadmill running trials on two occasions seven days apart. Stride time and sacral acceleration signals were obtained using IMUs. Stride time variability and complexity were calculated using the coefficient of variation (CV) and detrended fluctuation analysis (DFA), respectively. Sacral acceleration regularity was quantified using sample entropy with a range of input parameters m (vector length) and r (similarity threshold). Between-day reliability was assessed using the intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimum detectable change. Stride time CV displayed moderate relative reliability (ICC = 0.672), but with a large absolute minimum detectable change = 0.525 %, whilst stride time DFA-alpha displayed poor relative reliability (ICC = 0.457) and yielded large minimum detectable changes (>= 0.208). Sample entropy displayed good relative reliability in mediolateral and resultant sacral acceleration signals for certain combinations of the parameters m and r , although again with large minimum detectable changes. Researchers should be cognisant of these reliability metrics when interpreting changes in running gait variability measures in clinical contexts.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Validity and Reliability of Thoracic-Mounted Inertial Measurement Units to Derive Gait Characteristics During Running
    Horsley, Benjamin J.
    Tofari, Paul J.
    Halson, Shona L.
    Kemp, Justin G.
    Chalkley, Daniel
    Cole, Michael H.
    Johnston, Rich D.
    Cormack, Stuart J.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2024, 38 (02) : 274 - 282
  • [2] The One- week Reliability Of Spatiotemporal Running Gait Characteristics Using Insole-embedded Inertial Measurement Units.
    Gaiesky, Sean K. T.
    Kim, Minju
    Li, Meihui
    Napier, Christopher
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2023, 55 (09) : 67 - 67
  • [3] Predicting Tissue Loads in Running from Inertial Measurement Units
    Rasmussen, John
    Skejo, Sebastian
    Waagepetersen, Rasmus Plenge
    SENSORS, 2023, 23 (24)
  • [4] Validity and reliability of inertial measurement units for gait assessment within a post stroke population
    Desai, Radhika
    Martelli, Dario
    Alomar, Jehan A.
    Agrawal, Sunil
    Quinn, Lori
    Bishop, Lauri
    TOPICS IN STROKE REHABILITATION, 2024, 31 (03) : 235 - 243
  • [5] Gait Recognition Based on Minirocket with Inertial Measurement Units
    Yan, Jianjun
    Xiong, Weixiang
    Jin, Li
    Jiang, Jinlin
    Yang, Zhihao
    Shi, Jiangtao
    Hu, Shuai
    INTERNATIONAL JOURNAL OF HUMANOID ROBOTICS, 2023, 20 (05)
  • [6] Validity and reliability of inertial measurement units measurements for running kinematics in different foot strike pattern runners
    Zeng, Ziwei
    Liu, Yue
    Li, Pan
    Wang, Lin
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [7] ASSESSMENT OF CLINICALLY-MEANINGFUL AGE AND KNEE OSTEOARTHRITIS GAIT MEASURES USING INERTIAL MEASUREMENT UNITS
    Hafer, J. F.
    Kern, K. L.
    Provenzano, S. G.
    Agresta, C. E.
    Zernicke, R. F.
    OSTEOARTHRITIS AND CARTILAGE, 2019, 27 : S124 - S124
  • [8] Evaluation of spinal posture during gait with inertial measurement units
    Digo, Elisa
    Pierro, Giuseppina
    Pastorelli, Stefano
    Gastaldi, Laura
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2020, 234 (10) : 1094 - 1105
  • [9] Validity and repeatability of inertial measurement units for measuring gait parameters
    Washabaugh, Edward P.
    Kalyanaraman, Tarun
    Adamczyk, Peter G.
    Claflin, Edward S.
    Krishnan, Chandramouli
    GAIT & POSTURE, 2017, 55 : 87 - 93
  • [10] Inertial Measurement Units: A Brief State of the Art on Gait Analysis
    Ribeiro, Nuno Ferrete
    Santos, Cristina P.
    2017 IEEE 5TH PORTUGUESE MEETING ON BIOENGINEERING (ENBENG), 2017,