Diagnostic performance of deep learning for infectious keratitis: a systematic review and meta-analysis

被引:0
|
作者
Ong, Zun Zheng [1 ]
Sadek, Youssef [2 ]
Qureshi, Riaz [3 ,4 ]
Liu, Su-Hsun [3 ,4 ]
Li, Tianjing [3 ,4 ]
Liu, Xiaoxuan [5 ,6 ,7 ]
Takwoingi, Yemisi [8 ]
Sounderajah, Viknesh [9 ]
Ashrafian, Hutan [9 ]
Ting, Daniel S. W. [10 ,11 ]
Mehta, Jodhbir S. [10 ,11 ]
Rauz, Saaeha [1 ,5 ]
Said, Dalia G. [12 ,13 ]
Dua, Harminder S. [12 ,13 ]
Burton, Matthew J. [14 ,15 ,16 ]
Ting, Darren S. J. [1 ,5 ,11 ,12 ]
机构
[1] Sandwell & West Birmingham NHS Trust, Birmingham & Midland Eye Ctr, Birmingham, England
[2] Univ Birmingham, Coll Med & Hlth, Birmingham Med Sch, Birmingham, England
[3] Univ Coloradom, Dept Epidemiol, Anschutz Med Campus, Aurora, CO USA
[4] Univ Coloradom, Dept Epidemiol, Anschutz Med Campus, Aurora, CO USA
[5] Univ Birmingham, Inst fl ammat & Ageing, Birmingham B15 2TT, England
[6] Univ Hosp Birmingham NHS Fdn Trust, Dept Ophthalmol, Birmingham, England
[7] Hlth Data Res UK, London, England
[8] Univ Birmingham, Dept Appl Hlth Sci, Birmingham, England
[9] Imperial Coll London, Inst Global Hlth Innovat, London, England
[10] Singapore Natl Eye Ctr, Singapore Eye Res Inst, Singapore, Singapore
[11] Duke NUS Med Sch, Ophthalmol & Visual Sci Acad Clin Program, Singapore, Singapore
[12] Univ Nottingham, Sch Med, Acad Ophthalmol, Nottingham, England
[13] Queens Med Ctr, Dept Ophthalmol, Nottingham, England
[14] London Sch Hyg & Trop Med, Int Ctr Eye Hlth, London, England
[15] UCL, Moorfields Eye Hosp NHS Fdn Trust, London, England
[16] UCL Inst Ophthalmol, London, England
基金
英国惠康基金;
关键词
Artificial fi cial intelligence; Corneal infection; Corneal ulcer; Deep learning; Infectious keratitis; Microbial keratitis; FUNGAL KERATITIS; BACTERIAL; ACCURACY; DISEASES; IMAGES;
D O I
10.1016/j.eclinm.2024.102887
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Infectious keratitis (IK) is the leading cause of corneal blindness globally. Deep learning (DL) is an emerging tool for medical diagnosis, though its value in IK is unclear. We aimed to assess the diagnostic accuracy of DL for IK and its comparative accuracy with ophthalmologists. Methods In this systematic review and meta-analysis, we searched EMBASE, MEDLINE, and clinical registries for studies related to DL for IK published between 1974 and July 16, 2024. We performed meta-analyses using bivariate models to estimate summary sensitivities and specificities. fi cities. This systematic review was registered with PROSPERO (CRD42022348596). Findings Of 963 studies identified, fi ed, 35 studies (136,401 corneal images from >56,011 patients) were included. Most studies had low risk of bias (68.6%) and low applicability concern (91.4%) in all domains of QUADAS-2, except the index test domain. Against the reference standard of expert consensus and/or microbiological results (seven external validation studies; 10,675 images), the summary estimates (95% CI) for sensitivity and specificity fi city of DL for IK were 86.2% (71.6-93.9) - 93.9) and 96.3% (91.5-98.5). - 98.5). From 28 internal validation studies (16,059 images), summary estimates for sensitivity and specificity fi city were 91.6% (86.8-94.8) - 94.8) and 90.7% (84.8-94.5). - 94.5). Based on seven studies (4007 images), DL and ophthalmologists had comparable summary sensitivity [89.2% (82.2-93.6) - 93.6) versus 82.2% (71.5-89.5); - 89.5); P = 0.20] and specificity fi city [(93.2% (85.5-97.0) - 97.0) versus 89.6% (78.8-95.2); - 95.2); P = 0.45]. Interpretation DL models may have good diagnostic accuracy for IK and comparable performance to ophthalmologists. These fi ndings should be interpreted with caution due to the image-based analysis that did not account for potential correlation within individuals, relatively homogeneous population studies, lack of pre-specification fi cation of DL thresholds, and limited external validation. Future studies should improve their reporting, data diversity, external validation, transparency, and explainability to increase the reliability and generalisability of DL models for clinical deployment.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Diagnostic performance of deep learning models for infectious keratitis: a systematic review and meta-analysis
    Ong, Zun Zheng
    Sadek, Youssef
    Qureshi, Riaz
    Liu, Alison Su-Hsun
    Ting, Darren S. J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [2] Diagnostic performance of deep learning in infectious keratitis: a systematic review and meta-analysis protocol
    Ong, Zun Zheng
    Sadek, Youssef
    Liu, Xiaoxuan
    Qureshi, Riaz
    Liu, Su-Hsun
    Li, Tianjing
    Sounderajah, Viknesh
    Ashrafian, Hutan
    Ting, Daniel Shu Wei
    Said, Dalia G.
    Mehta, Jodhbir S.
    Burton, Matthew J.
    Dua, Harminder Singh
    Ting, Darren Shu Jeng
    BMJ OPEN, 2023, 13 (05):
  • [3] Amniotic membrane transplantation for infectious keratitis: a systematic review and meta-analysis
    Ting, Darren Shu Jeng
    Henein, Christin
    Said, Dalia G.
    Dua, Harminder S.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [4] Amniotic membrane transplantation for infectious keratitis: a systematic review and meta-analysis
    Darren Shu Jeng Ting
    Christin Henein
    Dalia G. Said
    Harminder S. Dua
    Scientific Reports, 11
  • [5] Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis
    Aggarwal, Ravi
    Sounderajah, Viknesh
    Martin, Guy
    Ting, Daniel S. W.
    Karthikesalingam, Alan
    King, Dominic
    Ashrafian, Hutan
    Darzi, Ara
    NPJ DIGITAL MEDICINE, 2021, 4 (01)
  • [6] Diagnostic accuracy of deep learning in orthopaedic fractures: a systematic review and meta-analysis
    Yang, S.
    Yin, B.
    Cao, W.
    Feng, C.
    Fan, G.
    He, S.
    CLINICAL RADIOLOGY, 2020, 75 (09) : 713.e17 - 713.e28
  • [7] Diagnostic accuracy of deep learning in prediction of osteoporosis: a systematic review and meta-analysis
    Amani, Firouz
    Amanzadeh, Masoud
    Hamedan, Mahnaz
    Amani, Paniz
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [8] Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis
    Ravi Aggarwal
    Viknesh Sounderajah
    Guy Martin
    Daniel S. W. Ting
    Alan Karthikesalingam
    Dominic King
    Hutan Ashrafian
    Ara Darzi
    npj Digital Medicine, 4
  • [9] Deep learning models for tendinopathy detection: a systematic review and meta-analysis of diagnostic tests
    Droppelmann, Guillermo
    Rodriguez, Constanza
    Smague, Dali
    Jorquera, Carlos
    Feijoo, Felipe
    EFORT OPEN REVIEWS, 2024, 9 (10) : 941 - 952
  • [10] Performance of deep learning in the detection of intracranial aneurysm: systematic review and meta-analysis
    Gu, Feng
    Wu, Xiaoxiao
    Wu, Wenxue
    Wang, Zilan
    Yang, Xingyu
    Chen, Zhouqing
    Wang, Zhong
    Chen, Gang
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 155