R2* Impact on Hepatic Fat Quantification With a Commercial Single Voxel Technique at 1.5 and 3.0 T

被引:1
|
作者
Fortier, Veronique [1 ,2 ,3 ,4 ]
Mohamed, Ahmed [5 ]
McNabb, Evan [1 ]
Dana, Jeremy [1 ]
Zakarian, Rita [6 ]
Levesque, Ives [3 ,4 ,6 ]
Reinhold, Caroline [1 ,2 ,6 ,7 ]
机构
[1] McGill Univ, Hlth Ctr, Dept Med Imaging, Glen Site C02 5505 1001 boul Decarie, Montreal, PQ H4A 3J1, Canada
[2] McGill Univ, Diag Radiol, Montreal, PQ, Canada
[3] McGill Univ, Gerald Bronfman Dept Oncol, Montreal, PQ, Canada
[4] McGill Univ, Med Phys Unit, Montreal, PQ, Canada
[5] Cairo Univ, Radiol Dept, NCI, Cairo, Egypt
[6] McGill Univ, Res Inst, Hlth Ctr, Montreal, PQ, Canada
[7] Montreal Imaging Experts Inc, Montreal, PQ, Canada
关键词
liver; fat quantification; HISTO; iron; R-2; IRON; MRI; LIVER; SPECTROSCOPY; DIXON; RELAXATION; FRACTION;
D O I
10.1177/08465371241255896
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Fat quantification accuracy using a commercial single-voxel high speed T2-corrected multi-echo (HISTO) technique and its robustness to R2* variations at 3.0 T, such as those introduced by iron in liver, has not been fully established. This study evaluated HISTO at 3.0 T and sought to reproduce results at 1.5 T. Methods: Phantoms were prepared with a range of fat content and R2*. Data were acquired at 1.5 T and 3.0 T, using HISTO and a Dixon technique. Fat quantification accuracy was evaluated as a function of R2*. The patient study included 239 consecutive patients. Data were acquired at 1.5 T or 3.0 T, using HISTO and Dixon techniques. The techniques were compared using Bland-Altman plots. Bias significance was evaluated using a one-sample t-test. Results: In phantoms, HISTO was accurate within 10% up to a R2* of 100 s-1 at both field strengths, while Dixon was accurate within 10% where R2* was accurately quantified (up to 350 s-1 at 1.5 T, and 550 s-1 at 3.0 T). In patients, where R2* was <100 s-1, fat quantification from both techniques agreed at 1.5 T (P = .71), but not at 3.0 T (P = .007), with a bias <1%. Conclusion: Results suggest that HISTO is reliable when R2* is <100 s-1, corresponding to patients with at most mild liver iron overload, and that it should be used with caution when R2* is >100 s-1. Dixon should be preferred for hepatic fat quantification due to its robustness to R2* variations. Visual Abstract This is a visual representation of the abstract.
引用
收藏
页码:838 / 846
页数:9
相关论文
共 50 条
  • [1] Practical Application of Multivendor MRI-Based R2 Mapping for Liver Iron Quantification at 1.5 T and 3.0 T
    Simchick, Gregory
    Zhao, Ruiyang
    Yuan, Qing
    Ghasabeh, Mounes Aliyari
    Ruschke, Stefan
    Karampinos, Dimitrios C.
    Harris, David T.
    do Vale Souza, Raphael
    Mattison, Ryan J.
    Jeng, Michael R.
    Pedrosa, Ivan
    Kamel, Ihab R.
    Vasanawala, Shreyas
    Yokoo, Takeshi
    Reeder, Scott B.
    Hernando, Diego
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025, 61 (01) : 150 - 165
  • [2] Editorial for "Practical Application of Multivendor MRI-Based R2 Mapping for Liver Iron Quantification at 1.5 T and 3.0 T"
    Wunderlich, Arthur P.
    Schmidt, Stefan A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025, 61 (01) : 166 - 167
  • [3] Relationships between MR transverse relaxation parameters R2*, R2 and R2′ and hepatic iron content in thalassemic mice at 1.5 T and 3 T
    Song, Ruitian
    Lin, Wei
    Chen, Qiukan
    Asakura, Toshio
    Wehrli, Felix W.
    Song, Hee Kwon
    NMR IN BIOMEDICINE, 2008, 21 (06) : 574 - 580
  • [4] ΔR2*in Fetal Sheep Brains during Hypoxia: MR Imaging at 3.0 T versus That at 1.5 T
    Wedegaertner, Ulrike
    Popovych, Sergyj
    Yamamura, Jin
    Kooijman, Hendrik
    Adam, Gerhard
    RADIOLOGY, 2009, 252 (02) : 394 - 400
  • [5] Non-invasive quantification of hepatic fat fraction by fast 1.0, 1.5 and 3.0T MR imaging
    Schuchmann, Sebastian
    Weigel, Christiane
    Albrecht, Lothar
    Kirsch, Michael
    Lemke, Arne
    Lorenz, Gerd
    Warzok, Rolf
    Hosten, Norbert
    EUROPEAN JOURNAL OF RADIOLOGY, 2007, 62 (03) : 416 - 422
  • [6] Single-voxel proton MRS of the human brain at 1.5T and 3.0T
    Barker, PB
    Hearshen, DO
    Boska, MD
    MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (05) : 765 - 769
  • [7] Simultaneous R2*, R2, and R2′ Quantification by Combining S0 Estimation of the Free Induction Decay with a Single Spin Echo: A Single Acquisition Method for R2 Insensitive Quantification of Holmium-166-Loaded Microspheres
    van de Maat, G. H.
    de Leeuw, H.
    Seevinck, P. R.
    van den Bosch, M. A. A. J.
    Nijsen, J. F. W.
    Bakker, C. J. G.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (01) : 273 - 283
  • [8] Changes in the MR relaxation rate R2* induced by respiratory challenges at 3.0 T: a comparison of two quantification methods
    Murtz, Petra
    Flacke, Sebastian
    Muller, Andreas
    Soehle, Martin
    Wenningmann, Ingobert
    Kovacs, Attila
    Traber, Frank
    Willinek, Winfried A.
    Gieseke, Jurgen
    Schild, Hans H.
    Remmele, Stefanie
    NMR IN BIOMEDICINE, 2010, 23 (09) : 1053 - 1060
  • [9] Improved liver fat and R2* quantification at 0.55 T using locally low-rank denoising
    Shih, Shu-Fu
    Tasdelen, Bilal
    Yagiz, Ecrin
    Zhang, Zhaohuan
    Zhong, Xiaodong
    Cui, Sophia X.
    Nayak, Krishna S.
    Wu, Holden H.
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (03) : 1348 - 1364
  • [10] Free-breathing MRI techniques for fat and R2* quantification in the liver
    Shih, Shu-Fu
    Wu, Holden H.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2024, 37 (04): : 583 - 602