R2* Impact on Hepatic Fat Quantification With a Commercial Single Voxel Technique at 1.5 and 3.0 T

被引:1
|
作者
Fortier, Veronique [1 ,2 ,3 ,4 ]
Mohamed, Ahmed [5 ]
McNabb, Evan [1 ]
Dana, Jeremy [1 ]
Zakarian, Rita [6 ]
Levesque, Ives [3 ,4 ,6 ]
Reinhold, Caroline [1 ,2 ,6 ,7 ]
机构
[1] McGill Univ, Hlth Ctr, Dept Med Imaging, Glen Site C02 5505 1001 boul Decarie, Montreal, PQ H4A 3J1, Canada
[2] McGill Univ, Diag Radiol, Montreal, PQ, Canada
[3] McGill Univ, Gerald Bronfman Dept Oncol, Montreal, PQ, Canada
[4] McGill Univ, Med Phys Unit, Montreal, PQ, Canada
[5] Cairo Univ, Radiol Dept, NCI, Cairo, Egypt
[6] McGill Univ, Res Inst, Hlth Ctr, Montreal, PQ, Canada
[7] Montreal Imaging Experts Inc, Montreal, PQ, Canada
关键词
liver; fat quantification; HISTO; iron; R-2; IRON; MRI; LIVER; SPECTROSCOPY; DIXON; RELAXATION; FRACTION;
D O I
10.1177/08465371241255896
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Fat quantification accuracy using a commercial single-voxel high speed T2-corrected multi-echo (HISTO) technique and its robustness to R2* variations at 3.0 T, such as those introduced by iron in liver, has not been fully established. This study evaluated HISTO at 3.0 T and sought to reproduce results at 1.5 T. Methods: Phantoms were prepared with a range of fat content and R2*. Data were acquired at 1.5 T and 3.0 T, using HISTO and a Dixon technique. Fat quantification accuracy was evaluated as a function of R2*. The patient study included 239 consecutive patients. Data were acquired at 1.5 T or 3.0 T, using HISTO and Dixon techniques. The techniques were compared using Bland-Altman plots. Bias significance was evaluated using a one-sample t-test. Results: In phantoms, HISTO was accurate within 10% up to a R2* of 100 s-1 at both field strengths, while Dixon was accurate within 10% where R2* was accurately quantified (up to 350 s-1 at 1.5 T, and 550 s-1 at 3.0 T). In patients, where R2* was <100 s-1, fat quantification from both techniques agreed at 1.5 T (P = .71), but not at 3.0 T (P = .007), with a bias <1%. Conclusion: Results suggest that HISTO is reliable when R2* is <100 s-1, corresponding to patients with at most mild liver iron overload, and that it should be used with caution when R2* is >100 s-1. Dixon should be preferred for hepatic fat quantification due to its robustness to R2* variations. Visual Abstract This is a visual representation of the abstract.
引用
收藏
页码:838 / 846
页数:9
相关论文
共 50 条
  • [21] Impact of particle size on R2* and fat fraction estimation for accurate assessment of hepatic iron overload and steatosis using MRI
    Shrestha, Utsav
    Brasher, Sarah
    Abramson, Zachary
    Morin, Cara E.
    Tipirneni-Sajja, Aaryani
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (05) : 2176 - 2185
  • [22] Intracranial Tumor Response to Respiratory Challenges at 3.0 T: Impact of Different Methods to Quantify Changes in the MR Relaxation Rate R2*
    Mueller, Andreas
    Remmele, Stefanie
    Wenningmann, Ingobert
    Clusmann, Hans
    Traeber, Frank
    Flacke, Sebastian
    Koenig, Roy
    Gieseke, Juergen
    Willinek, Winfried A.
    Schild, Hans H.
    Muertz, Petra
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (01) : 17 - 23
  • [23] On the performance of T2*correction methods for quantification of hepatic fat content
    Reeder, Scott B.
    Bice, Emily K.
    Yu, Huanzhou
    Hernando, Diego
    Pineda, Angel R.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 389 - 404
  • [24] Hepatic steatosis modeling and MRI signal simulations for comparison of single- and dual-R2* models and estimation of fat fraction at 1.5T and 3T
    Shrestha U.
    Esparza J.P.
    Satapathy S.K.
    Vanatta J.M.
    Abramson Z.R.
    Tipirneni-Sajja A.
    Comput. Biol. Med., 2024,
  • [25] A comparison of single-voxel clinical in vivo hepatic 31P MR spectra acquired at 1.5 and 3.0 Tesla in health and diseased states
    Wylezinska, Marzena
    Cobbold, Jeremy F. L.
    Fitzpatrick, Julie
    McPhail, Mark J. W.
    Crossey, Mary M. E.
    Thomas, Howard C.
    Hajnal, Joseph V.
    Vennart, William
    Cox, I. Jane
    Taylor-Robinson, Simon D.
    NMR IN BIOMEDICINE, 2011, 24 (03) : 231 - 237
  • [26] Cell density quantification with TurboSPI: R2* mapping with compensation for off-resonance fat modulation
    O'Brien-Moran, Zoe
    Van Bowen, Chris
    Rioux, James Allen
    Brewer, Kimberly Dawn
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2020, 33 (04) : 469 - 481
  • [27] Cell density quantification with TurboSPI: R2* mapping with compensation for off-resonance fat modulation
    Zoe O’Brien-Moran
    Chris Van Bowen
    James Allen Rioux
    Kimberly Dawn Brewer
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2020, 33 : 469 - 481
  • [28] R2 MRI quantification of hepatic iron: an additional tool in the management of patients with HFE gene mutations
    Crooks, B. J.
    Thomas, A. S.
    Davis, B. A.
    Shah, F.
    BRITISH JOURNAL OF HAEMATOLOGY, 2015, 169 : 22 - 22
  • [29] R2*Relaxometry for the Quantification of Hepatic Iron Overload: Biopsy-Based Calibration and Comparison with the Literature
    Henninger, B.
    Zoller, H.
    Rauch, S.
    Finkenstedt, A.
    Schocke, M.
    Jaschke, W.
    Kremser, C.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2015, 187 (06): : 472 - 479
  • [30] Effect of gadolinium on hepatic fat quantification using multi-echo reconstruction technique with T2*correction and estimation
    Ge, Mingmei
    Zhang, Jing
    Wu, Bing
    Liu, Zhiqin
    Song, Hai
    Meng, Xiangfeng
    Wu, Xinhuai
    EUROPEAN RADIOLOGY, 2016, 26 (06) : 1913 - 1920