Simultaneous R2*, R2, and R2′ Quantification by Combining S0 Estimation of the Free Induction Decay with a Single Spin Echo: A Single Acquisition Method for R2 Insensitive Quantification of Holmium-166-Loaded Microspheres

被引:4
|
作者
van de Maat, G. H. [1 ]
de Leeuw, H. [1 ]
Seevinck, P. R. [1 ]
van den Bosch, M. A. A. J. [2 ]
Nijsen, J. F. W. [2 ]
Bakker, C. J. G. [2 ]
机构
[1] Univ Med Ctr Utrecht, Image Sci Inst, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Radiol & Nucl Med, Utrecht, Netherlands
关键词
SOFIDSE; holmium microspheres; R-2*; R-2; S-0; estimation; quantification; POLY(L-LACTIC ACID) MICROSPHERES; HOLMIUM-LOADED MICROSPHERES; LIVER-TUMORS; NMR SIGNAL; TRANSVERSE-RELAXATION; BIODISTRIBUTION; TRACKING; BEHAVIOR; THERAPY; TISSUES;
D O I
10.1002/mrm.25138
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To present a new method, S-0 estimation of the free induction decay combined with a single spin echo measurement (SOFIDSE), that enables simultaneous measurements of R-2*, R-2, and R-2 in order to quantify the local concentration of holmium microspheres (Ho-MS) for radioembolization. Theory and Methods: SOFIDSE estimates R-2* and the signal magnitude at time point 0, S-0, from a multigradient echo readout of the free induction decay and subsequently estimates R-2 using S-0 and a single spin echo, from which R-2 is deducted. The method was evaluated by comparing SOFIDSE R-2 values with values obtained from shifted spin echo (SSE) measurements on a phantom setup containing Ho-MS and from dual spin echo measurements on a healthy volunteer. Results: On average, SOFIDSE showed a small overestimation of R-2 values compared with SSE independent of the microsphere concentration. R-2 values determined by subtraction of either SOFIDSE R-2 or SSE R-2 from R-2* showed excellent agreement (correlation coefficient = 1; P = 9 10(-11)). The Ho-MS-induced R-2 values obtained by SOFIDSE were insensitive to the R-2 value of the tissue in which they resided. Conclusion: SOFIDSE enables quantification of Ho-MS, in media with spatially or temporally varying R-2 values, in a single acquisition. Magn Reson Med 73:273-283, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:273 / 283
页数:11
相关论文
共 50 条
  • [1] Reproducibility of liver R2* quantification for liver iron quantification from cardiac R2* acquisitions
    M. R. Muehler
    K. Vigen
    D. Hernando
    A. Zhu
    T. J. Colgan
    S. B. Reeder
    Abdominal Radiology, 2021, 46 : 4200 - 4209
  • [2] Reproducibility of liver R2*quantification for liver iron quantification from cardiac R2*acquisitions
    Muehler, M. R.
    Vigen, K.
    Hernando, D.
    Zhu, A.
    Colgan, T. J.
    Reeder, S. B.
    ABDOMINAL RADIOLOGY, 2021, 46 (09) : 4200 - 4209
  • [3] Evaluation of renal oxygenation change under the influence of carbogen breathing using a dynamic R2, R2 and R2* quantification approach
    Wang, Chengyan
    Zhao, Kai
    Zhang, Rui
    Jiang, Li
    Wang, Rui
    Zhang, Xiaodong
    Wang, He
    Jin, Lixin
    Zhang, Jue
    Wang, Xiaoying
    Fang, Jing
    NMR IN BIOMEDICINE, 2016, 29 (11) : 1601 - 1607
  • [4] Spin-echo SS-PARSE: a PARSE MRI method to estimate frequency, R2 and R2′ in a single shot
    Li, Ningzhi
    Bolding, Mark
    Twieg, Donald B.
    MAGNETIC RESONANCE IMAGING, 2010, 28 (09) : 1270 - 1282
  • [5] Simultaneous dynamic R2 R2' and R2*measurement using periodic pulse shifting multiecho asymmetric spin echo sequence moving estimation strategy: A feasibility study for lower extremity muscle
    Wang, Chengyan
    Zhang, Rui
    Zhang, Xiaodong
    Wang, He
    Zhao, Kai
    Jin, Lixin
    Zhang, Jue
    Wang, Xiaoying
    Fang, Jing
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (02) : 766 - 773
  • [6] Echo-spacing optimization for the simultaneous measurement of reversible (R2′) and irreversible (R2) transverse relaxation rates
    Song, Ruitian
    Song, Hee Kwon
    MAGNETIC RESONANCE IMAGING, 2007, 25 (01) : 63 - 68
  • [7] R2 prime (R2′) magnetic resonance imaging for post-myocardial infarction intramyocardial haemorrhage quantification
    Rossello, Xavier
    Lopez-Ayala, Pedro
    Fernandez-Jimenez, Rodrigo
    Oliver, Eduardo
    Galan-Arriola, Carlos
    de Molina-Iracheta, Antonio
    Aguero, Jaume
    LoPez, Gonzalo J.
    Lobo-Gonzalez, Manuel
    Vilchez-Tschischke, Jean Paul
    Fuster, Valentin
    Sanchez-Gonzalez, Javier
    Ibanez, Borja
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2020, 21 (09) : 1031 - 1038
  • [8] Concurrent MR Blood Volume and Vessel Size Estimation in Tumors by Robust and Simultaneous ΔR2 and ΔR*2 Quantification
    Remmele, Stefanie
    Ring, Janine
    Senegas, Julien
    Heindel, Walter
    Mesters, Rolf M.
    Bremer, Christoph
    Persigehl, Thorsten
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (01) : 144 - 153
  • [9] Spin-echo SS-PARSE: a PARSE MRI method to estimate frequency, R2 and R2′ in a single shot (vol 28, pg 1270, 2010)
    Li, Ningzhi
    Bolding, Mark
    Twieg, Donald B.
    MAGNETIC RESONANCE IMAGING, 2011, 29 (08) : 1155 - 1155
  • [10] R2* as a Surrogate Measure of FerriScan Iron Quantification in Thalassemia
    Chan, Wesley C.
    Tejani, Zahra
    Budhani, Faisal
    Massey, Christine
    Haider, Masoom A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (04) : 1007 - 1011