Simultaneous R2*, R2, and R2′ Quantification by Combining S0 Estimation of the Free Induction Decay with a Single Spin Echo: A Single Acquisition Method for R2 Insensitive Quantification of Holmium-166-Loaded Microspheres

被引:4
|
作者
van de Maat, G. H. [1 ]
de Leeuw, H. [1 ]
Seevinck, P. R. [1 ]
van den Bosch, M. A. A. J. [2 ]
Nijsen, J. F. W. [2 ]
Bakker, C. J. G. [2 ]
机构
[1] Univ Med Ctr Utrecht, Image Sci Inst, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Radiol & Nucl Med, Utrecht, Netherlands
关键词
SOFIDSE; holmium microspheres; R-2*; R-2; S-0; estimation; quantification; POLY(L-LACTIC ACID) MICROSPHERES; HOLMIUM-LOADED MICROSPHERES; LIVER-TUMORS; NMR SIGNAL; TRANSVERSE-RELAXATION; BIODISTRIBUTION; TRACKING; BEHAVIOR; THERAPY; TISSUES;
D O I
10.1002/mrm.25138
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To present a new method, S-0 estimation of the free induction decay combined with a single spin echo measurement (SOFIDSE), that enables simultaneous measurements of R-2*, R-2, and R-2 in order to quantify the local concentration of holmium microspheres (Ho-MS) for radioembolization. Theory and Methods: SOFIDSE estimates R-2* and the signal magnitude at time point 0, S-0, from a multigradient echo readout of the free induction decay and subsequently estimates R-2 using S-0 and a single spin echo, from which R-2 is deducted. The method was evaluated by comparing SOFIDSE R-2 values with values obtained from shifted spin echo (SSE) measurements on a phantom setup containing Ho-MS and from dual spin echo measurements on a healthy volunteer. Results: On average, SOFIDSE showed a small overestimation of R-2 values compared with SSE independent of the microsphere concentration. R-2 values determined by subtraction of either SOFIDSE R-2 or SSE R-2 from R-2* showed excellent agreement (correlation coefficient = 1; P = 9 10(-11)). The Ho-MS-induced R-2 values obtained by SOFIDSE were insensitive to the R-2 value of the tissue in which they resided. Conclusion: SOFIDSE enables quantification of Ho-MS, in media with spatially or temporally varying R-2 values, in a single acquisition. Magn Reson Med 73:273-283, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:273 / 283
页数:11
相关论文
共 50 条
  • [31] Monitoring angiogenesis in brain using steady-state quantification of ΔR2 with MION infusion
    Dunn, JF
    Roche, MA
    Springett, R
    Abajian, M
    Merlis, J
    Daghlian, CP
    Lu, SY
    Makki, M
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) : 55 - 61
  • [32] The quantification of ΔR2* under brain activation:: dependence on relaxation rate at rest and significance threshold
    Wiener, E
    Settles, M
    Ganter, C
    MAGNETIC RESONANCE IMAGING, 2001, 19 (05) : 649 - 657
  • [33] DEPENDENCE OF SINGLE EFFECTIVE ACTION IN MULTIDIMENSIONAL R2 GRAVITATION ON METRIC OF CONFIGURATIONAL SPACE
    ODINTSOV, SD
    SHEVCHENKO, IN
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII FIZIKA, 1991, 34 (07): : 74 - 76
  • [34] Biophysically motivated efficient estimation of the spatially isotropic R2*component from a single gradient-recalled echo measurement
    Papazoglou, Sebastian
    Streubel, Tobias
    Ashtarayeh, Mohammad
    Pine, Kerrin J.
    Edwards, Luke J.
    Brammerloh, Malte
    Kirilina, Evgeniya
    Morawski, Markus
    Jaeger, Carsten
    Geyer, Stefan
    Callaghan, Martina F.
    Weiskopf, Nikolaus
    Mohammadi, Siawoosh
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (05) : 1804 - 1811
  • [35] Simultaneous imaging and R2*mapping using a radial multi-gradient-echo (rMGE) sequence
    Winkelmann, Stefanie
    Schaeffter, Tobias
    Weiss, Steffen
    Eggers, Holger
    Doessel, Olaf
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (04) : 939 - 944
  • [36] R2 MRI quantification of hepatic iron: an additional tool in the management of patients with HFE gene mutations
    Crooks, B. J.
    Thomas, A. S.
    Davis, B. A.
    Shah, F.
    BRITISH JOURNAL OF HAEMATOLOGY, 2015, 169 : 22 - 22
  • [37] R2*Relaxometry for the Quantification of Hepatic Iron Overload: Biopsy-Based Calibration and Comparison with the Literature
    Henninger, B.
    Zoller, H.
    Rauch, S.
    Finkenstedt, A.
    Schocke, M.
    Jaschke, W.
    Kremser, C.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2015, 187 (06): : 472 - 479
  • [38] High-speed spectroscopic imaging for cancellous bone marrow R2* mapping and lipid quantification
    Hilaire, L
    Wehrli, FW
    Song, HK
    MAGNETIC RESONANCE IMAGING, 2000, 18 (07) : 777 - 786
  • [39] Cell density quantification with TurboSPI: R2* mapping with compensation for off-resonance fat modulation
    O'Brien-Moran, Zoe
    Van Bowen, Chris
    Rioux, James Allen
    Brewer, Kimberly Dawn
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2020, 33 (04) : 469 - 481
  • [40] Cell density quantification with TurboSPI: R2* mapping with compensation for off-resonance fat modulation
    Zoe O’Brien-Moran
    Chris Van Bowen
    James Allen Rioux
    Kimberly Dawn Brewer
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2020, 33 : 469 - 481