Novel application of ScAlN PMUT for intravenous infusion drip monitoring

被引:0
|
作者
Yang, Lei [1 ,2 ]
Zhang, Jin [3 ]
Zhang, Long [1 ,2 ]
Zong, Jianwei [1 ,2 ]
Ren, Hao [4 ]
Lou, Liang [1 ,2 ]
机构
[1] Shanghai Univ, Sch Microelect, Shanghai 201800, Peoples R China
[2] Shanghai Ind Technol Res Inst, 235 Chengzhong Rd, Shanghai 201800, Peoples R China
[3] Shanghai Inst Microsyst & Informat Technol, Shanghai 201800, Peoples R China
[4] ShanghaiTech Univ, Sch Informat Sci & Technol, Room 3-328,393 Huaxia Middle Rd, Shanghai 201210, Peoples R China
关键词
PMUT; Low Power Consumption; Drip Monitoring; TRANSDUCERS; ERRORS;
D O I
10.1016/j.sna.2025.116326
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study, for the first time, demonstrates a drip meter using Scandium Aluminum Nitride Piezoelectric MicroElectromechanical Ultrasonic Transducer(ScAlN PMUT) chip as an "ear" in intravenous infusion application. The device can effectively detect the liquid waveform change caused by the drip. A clip structure is designed to ensure good contact between the sensor and the tube wall. The signal-to-noise ratio(SNR) is up to 14.5 dB and 10 dB at 5 drips per second (dps) and 11 dps, respectively. The relative error rate at 11 dps is measured below 0.8 %. With very low power consumption, low cost and high performance, the device proves ideal for long-term, continuous intravenous drip monitoring.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Wireless sensor network-enabled intravenous infusion monitoring
    Zhang, Y.
    Zhang, S. F.
    Ji, Y.
    Wu, G. X.
    IET WIRELESS SENSOR SYSTEMS, 2011, 1 (04) : 241 - 247
  • [42] System for monitoring the process continuity of the intravenous infusion - development study
    Josko, Adam
    Romanik, Wojciech
    Bahuslauski, Mikhail
    Majek, Maciej
    Sobczak, Maciej
    Zakrzewski, Maciej
    PRZEGLAD ELEKTROTECHNICZNY, 2023, 99 (11): : 261 - 264
  • [43] IDENTIFICATION OF THE EPIDURAL SPACE IN CHILDREN - THE APPLICATION OF A MICRO-DRIP INFUSION SET
    YAMASHITA, M
    TSUJI, M
    ANAESTHESIA, 1991, 46 (10) : 872 - 874
  • [44] A new drip infusion solution monitoring system with a free-flow detection function
    Ogawa, Hidekuni
    Maki, Hiromichi
    Tsukamoto, Sosuke
    Yonezawa, Yoshiharu
    Amano, Hikaru
    Caldwell, W. Morton
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 1214 - 1217
  • [45] Compliance to Guidelines by Emergency Medical Services in "Drip and Ship" Patients with In-Transit Intravenous Thrombolytic Infusion
    Asaithambi, Ganesh
    Chaudhry, Saqib
    Hassan, Ameer
    Rodriguez, Gustavo
    Suri, Muhammad
    Qureshi, Adnan
    NEUROLOGY, 2012, 78
  • [46] LABORATORY AND CLINICAL-STUDIES OF AMIKACIN INTRAVENOUS DRIP INFUSION FOR THE SEVERE INFECTIONS COMPLICATED WITH HEMATOLOGIC MALIGNANCIES
    SUGIURA, K
    SOTOYAMA, K
    NEGISHI, M
    AOKI, I
    OKAMOTO, S
    CHEN, DY
    ANDO, Y
    UCHIDA, H
    JAPANESE JOURNAL OF ANTIBIOTICS, 1981, 34 (06): : 832 - 840
  • [47] Intravenous Application of sterile Infusion versus non-sterile Infusion Solutions in Horses
    Hampe, Alexandra
    TIERAERZTLICHE PRAXIS AUSGABE GROSSTIERE NUTZTIERE, 2020, 48 (04):
  • [48] MONITORING OF INTRAVENOUS QUINIDINE INFUSION IN THE TREATMENT OF PLASMODIUM-FALCIPARUM MALARIA
    BHAVNANI, SM
    PRESTON, SL
    ANNALS OF PHARMACOTHERAPY, 1995, 29 (01) : 33 - 35
  • [49] INDUCTION OF MID-TRIMESTER ABORTION BY MEANS OF EXTRA-AMNIOTIC INFUSION OF AN ISOTONIC SALINE SOLUTION COMBINED WITH INTRAVENOUS OXYTOCIN DRIP INFUSION
    HALBRECHT, I
    BLUM, M
    CONTRACEPTION, 1974, 10 (06) : 637 - 643
  • [50] Monitoring of clinical signs of intravenous infusion patients with ZigBee wireless technology
    Zhu, Xiaobo
    Ye, Yunlong
    INTERNATIONAL JOURNAL OF DISTRIBUTED SENSOR NETWORKS, 2022, 18 (04)