Novel application of ScAlN PMUT for intravenous infusion drip monitoring

被引:0
|
作者
Yang, Lei [1 ,2 ]
Zhang, Jin [3 ]
Zhang, Long [1 ,2 ]
Zong, Jianwei [1 ,2 ]
Ren, Hao [4 ]
Lou, Liang [1 ,2 ]
机构
[1] Shanghai Univ, Sch Microelect, Shanghai 201800, Peoples R China
[2] Shanghai Ind Technol Res Inst, 235 Chengzhong Rd, Shanghai 201800, Peoples R China
[3] Shanghai Inst Microsyst & Informat Technol, Shanghai 201800, Peoples R China
[4] ShanghaiTech Univ, Sch Informat Sci & Technol, Room 3-328,393 Huaxia Middle Rd, Shanghai 201210, Peoples R China
关键词
PMUT; Low Power Consumption; Drip Monitoring; TRANSDUCERS; ERRORS;
D O I
10.1016/j.sna.2025.116326
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study, for the first time, demonstrates a drip meter using Scandium Aluminum Nitride Piezoelectric MicroElectromechanical Ultrasonic Transducer(ScAlN PMUT) chip as an "ear" in intravenous infusion application. The device can effectively detect the liquid waveform change caused by the drip. A clip structure is designed to ensure good contact between the sensor and the tube wall. The signal-to-noise ratio(SNR) is up to 14.5 dB and 10 dB at 5 drips per second (dps) and 11 dps, respectively. The relative error rate at 11 dps is measured below 0.8 %. With very low power consumption, low cost and high performance, the device proves ideal for long-term, continuous intravenous drip monitoring.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] INTRAVENOUS-INFUSION CONDITIONS - IMPLICATIONS FOR PHARMACOKINETIC MONITORING
    NAHATA, MC
    CLINICAL PHARMACOKINETICS, 1993, 24 (03) : 221 - 229
  • [32] Real-time drip infusion monitoring through a computer vision system
    Giaquinto, Nicola
    Scarpetta, Marco
    Ragolia, Mattia Alessandro
    Pappalardi, Pietro
    2020 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2020,
  • [33] The Application of Infusion Intelligent Monitoring System
    Jiang, Xingjia
    Yao, Caihong
    PROCEEDINGS OF THE 2015 6TH INTERNATIONAL CONFERENCE ON MANUFACTURING SCIENCE AND ENGINEERING, 2016, 32 : 1944 - 1947
  • [34] FUNDAMENTAL AND A FEW CLINICAL-STUDIES IN PEDIATRIC FIELD ON TOBRAMYCIN WITH INTRAVENOUS DRIP INFUSION METHOD
    NAKAZAWA, S
    SATO, H
    HIRAMA, Y
    NIINO, K
    NARITA, A
    NAKAZAWA, SI
    CHIKAOKA, H
    JAPANESE JOURNAL OF ANTIBIOTICS, 1981, 34 (08): : 1173 - 1177
  • [35] DOUBLE-BLIND COMPARISON OF IODIPAMIDE AND IODOXAMATE USING DIRECT AND DRIP INFUSION INTRAVENOUS CHOLANGIOGRAPHY
    MOSS, AA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1977, 128 (06) : 931 - 933
  • [36] TISSUE DISTRIBUTION OF METHOTREXATE IN RATS - A COMPARISON BETWEEN INTRAVENOUS-INJECTION AS BOLUS OR DRIP INFUSION
    MIGLIOLI, PA
    BUSINARO, V
    MANONI, F
    BERTI, T
    DRUGS UNDER EXPERIMENTAL AND CLINICAL RESEARCH, 1985, 11 (04) : 275 - 279
  • [37] AMINOGLYCOSIDE DRIP INTRAVENOUS-INFUSION FOR SEVERE INFECTIONS DUE TO LEUKEMIA AND HEMATOPOIETIC TUMOR PATIENTS
    FUJIOKA, S
    ASAI, T
    ITO, K
    SUGIURA, Y
    OH, H
    JAPANESE JOURNAL OF ANTIBIOTICS, 1981, 34 (01): : 7 - 15
  • [38] TISSUE DIFFUSION OF DOXYCYCLINE IN RATS - A COMPARISON BETWEEN INTRAVENOUS BOLUS INJECTION OR DRIP-INFUSION
    MIGLIOLI, PA
    CHEMIOTERAPIA, 1988, 7 (03): : 156 - 159
  • [39] Multimode optical fiber interrogator-based LiDAR for intravenous drip monitoring
    Jauregui-Vazquez, D.
    Baron-Casique, J.
    Guevara-Hernandez, S. D.
    Alvarez-Chavez, J. A.
    Fuentes-Ocampo, L.
    Mejia-Vega, O. A.
    Hernandez-Garcia, J. C.
    OPTICAL FIBER TECHNOLOGY, 2023, 81
  • [40] PHARMACOKINETIC BASES FOR PRACTICAL APPLICATION OF CARBENICILLIN BY INTRAVENOUS INFUSION
    MODR, Z
    DVORACEK, K
    PHARMAZIE, 1971, 26 (03): : 185 - &