Development and Validation of Targeted Metabolomics Methods Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) for the Quantification of 235 Plasma Metabolites

被引:0
|
作者
Xu, Kangkang [1 ,2 ,3 ]
Berthiller, Franz [1 ,2 ]
Metzler-Zebeli, Barbara U. [2 ,4 ]
Schwartz-Zimmermann, Heidi E. [1 ,2 ]
机构
[1] BOKU Univ, Inst Bioanalyt & Agrometabol, Dept Agr Sci, A-3430 Tulln, Austria
[2] Christian Doppler Lab Innovat Gut Hlth Concepts Li, A-1210 Vienna, Austria
[3] Austrian Competence Ctr Feed & Food Qual Safety &, A-3430 Tulln, Austria
[4] Univ Vet Med, Dept Biomed Sci, Unit Nutr Physiol, Vet Pl 1, A-1210 Vienna, Austria
来源
MOLECULES | 2025年 / 30卷 / 03期
关键词
metabolomics; plasma metabolites; targeted HPLC-MS/MS methods; HILIC; reversed-phase high-performance liquid chromatography; animal metabolomics; HIGH-THROUGHPUT; STRATEGIES; BIOMARKER;
D O I
10.3390/molecules30030706
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Plasma contains metabolites with diverse physicochemical properties, ranging from highly polar to highly apolar, and concentrations spanning at least nine orders of magnitude. Plasma metabolome analysis is valuable for monitoring health and evaluating medical interventions but is challenging due to the metabolome's diversity and complexity. This study aims to develop and validate targeted LC-MS/MS methods for quantifying 235 mammalian metabolites from 17 compound classes in porcine plasma without prior derivatization. Utilizing reversed-phase and hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry, each analyte is identified and quantified using two selected reaction monitoring (SRM) transitions. Fast polarity switching and scheduled SRM enhance the metabolome coverage and throughput, enabling the analysis of one sample in about 40 min. A simple "dilute and shoot" sample preparation protocol was employed, with samples injected at two dilution levels to align metabolite concentrations within calibration curve ranges. Validation in porcine plasma included assessments of carryover, linearity, detection and quantification limits, repeatability and recovery. The method was further applied to plasma samples from various animal species, demonstrating its applicability to human and animal studies. This study establishes two robust LC-MS/MS methods for comprehensive porcine plasma metabolome quantification, advancing large-scale targeted metabolomics in biomedical research.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Optimization of Targeted Plant Proteomics Using Liquid Chromatography with Tandem Mass Spectrometry (LC-MS/MS)
    Li, Weiwei
    Keller, Arturo A.
    ACS AGRICULTURAL SCIENCE & TECHNOLOGY, 2023, 3 (05): : 421 - 431
  • [22] Determination of Polyphenols Using Liquid Chromatography-Tandem Mass Spectrometry Technique (LC-MS/MS): A Review
    Lopez-Fernandez, Olalla
    Dominguez, Ruben
    Pateiro, Mirian
    Munekata, Paulo E. S.
    Rocchetti, Gabriele
    Lorenzo, Jose M.
    ANTIOXIDANTS, 2020, 9 (06)
  • [23] Simultaneous quantification of ferrous gluconate and calcium gluconate in foods using liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Park, Yeong-Ju
    Sim, Sol
    Jung, Soyeon
    Seo, Hyunji
    Lee, Yejin
    Lee, Jihyun
    Lee, Chan
    Suh, Hee-Jae
    APPLIED BIOLOGICAL CHEMISTRY, 2023, 66 (01)
  • [24] The Development of a Highly Sensitive Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method for the Validation of Flualprazolam and Isotonitazene in Serum
    Akbaba, Murat
    Isir, Aysun Baransel
    APPLIED SCIENCES-BASEL, 2025, 15 (05):
  • [25] KINETICS OF PLASMA APOLIPOPROTEIN E ISOFORMS IN HUMANS BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY (LC-MS/MS)
    Croyal, M.
    Blanchard, V.
    Ramin-Mangata, S.
    Ouguerram, K.
    Lambert, G.
    Krempf, M.
    ATHEROSCLEROSIS, 2018, 275 : E29 - E29
  • [26] Quantitation of Phenolic Benzotriazole Class Compounds in Plasma by Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)
    Mutlu, Esra
    South, Natalie
    Pierfelice, Jessica
    Djonabaye, Alison
    Pauff, Mindy
    Burback, Brian
    Waidyanatha, Suramya
    ANALYTICAL LETTERS, 2022, 55 (13) : 2074 - 2088
  • [27] Identification and quantification of the atypical metabolite ornithine-lactam in human plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Martens-Lobenhoffer, Jens
    Becker, Achim
    Freude, Horst
    Bode-Boeger, Stefanie M.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (23): : 2284 - 2289
  • [28] Development, Validation, and Comparison of Two Mass Spectrometry Methods (LC-MS/HRMS and LC-MS/MS) for the Quantification of Rituximab in Human Plasma
    Millet, Aurelien
    Khoudour, Nihel
    Lebert, Dorothee
    Machon, Christelle
    Terrier, Benjamin
    Blanchet, Benoit
    Guitton, Jerome
    MOLECULES, 2021, 26 (05):
  • [29] Rapid and sensitive method for the determination of sertraline in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Jain, DS
    Sanyal, M
    Subbaiah, G
    Pande, UC
    Shrivastav, P
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 829 (1-2): : 69 - 74
  • [30] Survey of microcystins in Singapore's reservoirs using liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Porojan, Cristina
    Abbas, Feras
    Mowe, Maxine A. D.
    Lehane, Mary
    Mitrovic, Simon M.
    Lim, Richard P.
    Yeo, Darren C. J.
    Furey, Ambrose
    MARINE AND FRESHWATER RESEARCH, 2020, 71 (05) : 659 - 672