The Development of a Highly Sensitive Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method for the Validation of Flualprazolam and Isotonitazene in Serum

被引:0
|
作者
Akbaba, Murat [1 ]
Isir, Aysun Baransel [1 ]
机构
[1] Gaziantep Univ, Fac Med, Dept Forens Med, TR-27310 Gaziantep, Turkiye
来源
APPLIED SCIENCES-BASEL | 2025年 / 15卷 / 05期
关键词
flualprazolam; isotonitazene; LC-MS/MS; method validation; serum level; solid-phase extraction;
D O I
10.3390/app15052267
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Objectives: This study aimed to develop and validate a sensitive and reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of flualprazolam and isotonitazene in serum samples to address critical gaps in forensic and clinical toxicology. Materials and Methods: A single-center validation study was conducted using serum samples spiked with analyte standards. Analytical parameters, including linearity, precision, recovery, the limit of detection (LOD), and the limit of quantification (LOQ), were evaluated in accordance with international guidelines. The LC-MS/MS method employed a Shimadzu Triple Quadrupole (TM) MS 8045 system with solid-phase extraction (SPE) for sample preparation. Results: The method exhibited high linearity for flualprazolam (r2 = 0.997) and isotonitazene (r2 = 0.999) over a concentration range of 1-100 ng/mL. The LODs were determined as 0.608 ng/mL and 0.192 ng/mL, and the LOQs were 1.842 ng/mL and 0.584 ng/mL for flualprazolam and isotonitazene, respectively. Recovery tests yielded results within the acceptable range of 70-120%. Flualprazolam demonstrated recovery rates of 98.0% and 97.0% at theoretical concentrations of 10 ng/mL and 50 ng/mL, respectively. In contrast, the isotonitazene recovery rates were slightly lower, measuring 75.5% at 10 ng/mL and 71.9% at 50 ng/mL, suggesting minor matrix effects that could influence its quantification. Precision analysis, including both repeatability and reproducibility, highlighted the reliability of the method. The %RSD values for flualprazolam were consistently below 7.07%, with mean concentrations closely aligning with theoretical values across fortification levels. For isotonitazene, the %RSD values remained below 6.24%, although recoveries at higher concentrations indicated potential challenges in matrix interaction. Conclusions: This validated LC-MS/MS method offers high sensitivity, precision, and recovery for detecting flualprazolam and isotonitazene in serum, filling a critical need in toxicological investigations. Further validation in other biological matrices is recommended to broaden its applicability.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay to quantify serum voriconazole
    Mak, Justin
    Sujishi, Kirk K.
    French, Deborah
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 986 : 94 - 99
  • [2] Simultaneous quantification of 18 different phytocannabinoids in serum using a highly sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method
    Scheunemann, A.
    Elsner, K.
    Germerott, T.
    Hess, C.
    Roehrich, J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1173
  • [3] Development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of voriconazole in human cerebrospinal fluid
    Dong, Liuhan
    Bai, Nan
    Wang, Tianlin
    Cai, Yun
    ANALYTICAL METHODS, 2021, 13 (39) : 4585 - 4593
  • [4] Development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of tigecycline in rat brain tissues
    Munyeza, Chiedza F.
    Shobo, Adeola
    Baijnath, Sooraj
    Bratkowska, Dominika
    Naiker, Suhashni
    Bester, Linda A.
    Singh, Sanil D.
    Maguire, Glenn E. M.
    Kruger, Hendrik G.
    Naicker, Tricia
    Govender, Thavendran
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (06) : 837 - 845
  • [5] Sensitive determination of paroxetine in canine plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Chang, Kyu Young
    Kang, Seung Woo
    Han, Sang Beom
    Youm, Jeong-Rok
    Lee, Kyung Ryul
    Lee, Hee Joo
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2007, 20 (02): : 138 - 146
  • [6] Rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of clonidine in human plasma
    Parekh, Sagar A.
    Pudage, Ashutosh
    Joshi, Santosh S.
    Vaidya, Vilas V.
    Gomes, Noel A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 867 (02): : 172 - 178
  • [7] A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the estimation of rivastigmine in human plasma
    Bhatt, Jignesh
    Subbaiah, Gunta
    Kambli, Sandeep
    Shah, Bhavin
    Nigam, Samita
    Patel, Mehul
    Saxena, Ashish
    Baliga, Ashok
    Parekh, Hetal
    Yadav, Gunvat
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 115 - 121
  • [8] A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the estimation of amlodipine in human plasma
    Bhatt, Jignesh
    Singh, Sadhana
    Subbaiah, Gunta
    Shah, Bhavin
    Kambli, Sandeep
    Ameta, Suresh
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (02) : 169 - 175
  • [9] Sensitive and specific liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for estimation of digoxin in human serum
    Hemanthkumar, K.
    Sam, V. A.
    Rathanakar, P.
    Chandramohan, K.
    Savale, S. S.
    Sundar, G.
    Singh, T.
    Nagraj, S.
    Arvind, A. S.
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 2007, 59 : A5 - A6
  • [10] Development and validation of a serum total testosterone liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay calibrated to NIST SRM 971
    French, Deborah