Development and Validation of Targeted Metabolomics Methods Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) for the Quantification of 235 Plasma Metabolites

被引:0
|
作者
Xu, Kangkang [1 ,2 ,3 ]
Berthiller, Franz [1 ,2 ]
Metzler-Zebeli, Barbara U. [2 ,4 ]
Schwartz-Zimmermann, Heidi E. [1 ,2 ]
机构
[1] BOKU Univ, Inst Bioanalyt & Agrometabol, Dept Agr Sci, A-3430 Tulln, Austria
[2] Christian Doppler Lab Innovat Gut Hlth Concepts Li, A-1210 Vienna, Austria
[3] Austrian Competence Ctr Feed & Food Qual Safety &, A-3430 Tulln, Austria
[4] Univ Vet Med, Dept Biomed Sci, Unit Nutr Physiol, Vet Pl 1, A-1210 Vienna, Austria
来源
MOLECULES | 2025年 / 30卷 / 03期
关键词
metabolomics; plasma metabolites; targeted HPLC-MS/MS methods; HILIC; reversed-phase high-performance liquid chromatography; animal metabolomics; HIGH-THROUGHPUT; STRATEGIES; BIOMARKER;
D O I
10.3390/molecules30030706
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Plasma contains metabolites with diverse physicochemical properties, ranging from highly polar to highly apolar, and concentrations spanning at least nine orders of magnitude. Plasma metabolome analysis is valuable for monitoring health and evaluating medical interventions but is challenging due to the metabolome's diversity and complexity. This study aims to develop and validate targeted LC-MS/MS methods for quantifying 235 mammalian metabolites from 17 compound classes in porcine plasma without prior derivatization. Utilizing reversed-phase and hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry, each analyte is identified and quantified using two selected reaction monitoring (SRM) transitions. Fast polarity switching and scheduled SRM enhance the metabolome coverage and throughput, enabling the analysis of one sample in about 40 min. A simple "dilute and shoot" sample preparation protocol was employed, with samples injected at two dilution levels to align metabolite concentrations within calibration curve ranges. Validation in porcine plasma included assessments of carryover, linearity, detection and quantification limits, repeatability and recovery. The method was further applied to plasma samples from various animal species, demonstrating its applicability to human and animal studies. This study establishes two robust LC-MS/MS methods for comprehensive porcine plasma metabolome quantification, advancing large-scale targeted metabolomics in biomedical research.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Detection of cannabinoids in dried blood spots by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Paul, Heather
    Awad, Hanan
    Sadrzadeh, S. M. Hossein
    Boyd, Jessica
    CLINICAL BIOCHEMISTRY, 2019, 74 : 93 - 93
  • [42] Matrix effect on the analysis of amphenicols in fish by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Guidi, L. R.
    Tette, P. A. S.
    Evangelista, W. P.
    Fernandes, C.
    Gloria, M. B. A.
    VII BRAZILIAN CONGRESS ON METROLOGY (METROLOGIA 2013), 2015, 575
  • [43] Development of a Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method for Characterizing Linalool Oral Pharmacokinetics in Humans
    Wang, Yan-Hong
    Mondal, Goutam
    Stevens, Nicole
    Bascoul, Cecile
    Osguthorpe, Russell J.
    Khan, Ikhlas A.
    Yates, Charles R.
    MOLECULES, 2023, 28 (18):
  • [44] Development of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for characterizing pomegranate extract pharmacokinetics in humans
    Wang, Yan-Hong
    Mondal, Goutam
    Khan, Washim
    Gurley, Bill J.
    Yates, Charles R.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 233
  • [45] Determination of more than 500 Pesticide Residues in Hen Eggs by Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) and Gas Chromatography-Tandem Mass Spectrometry (GC/MS/MS)
    Golge, Ozgur
    Liman, Turan
    Kabak, Bulent
    FOOD SCIENCE OF ANIMAL RESOURCES, 2021, 41 (05) : 816 - 825
  • [46] Quantification of 5,7-dimethoxyflavone in mouse plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS) and its application to a pharmacokinetic study
    Bei, Di
    An, Guohua
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 978 : 11 - 17
  • [47] Development and validation of a sensitive, simple, and rapid method for simultaneous quantitation of atorvastatin and its acid and lactone metabolites by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Joyce S. Macwan
    Ileana A. Ionita
    Miroslav Dostalek
    Fatemeh Akhlaghi
    Analytical and Bioanalytical Chemistry, 2011, 400 : 423 - 433
  • [48] Development and validation of a sensitive, simple, and rapid method for simultaneous quantitation of atorvastatin and its acid and lactone metabolites by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Macwan, Joyce S.
    Ionita, Ileana A.
    Dostalek, Miroslav
    Akhlaghi, Fatemeh
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (02) : 423 - 433
  • [49] Development and validation of a serum total testosterone liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay calibrated to NIST SRM 971
    French, Deborah
    CLINICA CHIMICA ACTA, 2013, 415 : 109 - 117
  • [50] Simultaneous quantification of 18 different phytocannabinoids in serum using a highly sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method
    Scheunemann, A.
    Elsner, K.
    Germerott, T.
    Hess, C.
    Roehrich, J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1173