Three-dimensional imaging of the forearm and hand: A comparison between two 3D imaging systems

被引:0
|
作者
van Ginkel, Laura [1 ,2 ]
Dupuis, Lotte [1 ]
Verhamme, Luc [3 ]
Hermans, Erik [1 ]
Maal, Thomas J. J. [3 ]
Stirler, Vincent [1 ]
机构
[1] Radboud Univ Nijmegen Med Ctr, Dept Trauma Surg, Nijmegen, Netherlands
[2] Univ Twente, Tech Med, Enschede, Netherlands
[3] Radboud Univ Nijmegen Med Ctr, Radboudumc 3D Lab, Nijmegen, Netherlands
来源
PLOS DIGITAL HEALTH | 2024年 / 3卷 / 04期
关键词
D O I
10.1371/journal.pdig.0000458
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The conventional treatment for distal radius fractures typically involves immobilization of the injured extremity using a conventional forearm cast. These casts do cause all sorts of discomfort during wear and impose life-style restrictions on the wearer. Personalized 3D printed splints, designed using three-dimensional (3D) imaging systems, might overcome these problems. To obtain a patient specific splint, commercially available 3D camera systems are utilized to capture patient extremities, generating 3D models for splint design. This study investigates the feasibility of utilizing a new camera system (SPENTYS) to capture 3D surface scans of the forearm for the design of 3D printed splints. In a prospective observational cohort study involving 17 healthy participants, we conducted repeated 3D imaging using both the new (SPENTYS) and a reference system (3dMD) to assess intersystem accuracy and repeatability. The intersystem accuracy of the SPENTYS system was determined by comparison of the 3D surface scans with the reference system (3dMD). Comparison of consecutive images acquired per device determined the repeatability. Feasibility was measured with system usability score questionnaires distributed among professionals. The mean absolute difference between the two systems was 0.44 mm (SD:0.25). The mean absolute difference of the repeatability of the reference -and the SPENTYS system was respectively 0.40 mm (SD: 0.30) and 0.53 mm (SD: 0.25). Both repeatability and intersystem differences were within the self-reported 1 mm. The workflow was considered easy and effective, emphasizing the potential of this approach within a workflow to obtain patient specific splint.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Three-dimensional imaging
    Nelson, TR
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 : S35 - S38
  • [32] A simple technique for sterility and patient accessibility during intraoperative three-dimensional (3D) imaging
    Luebbers, Heinz-Theo
    Zemann, Wolfgang
    Kruse, Astrid L.
    Graetz, Klaus W.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2013, 51 (08): : E312 - E313
  • [33] Review of three-dimensional (3D) surface imaging for oncoplastic, reconstructive and aesthetic breast surgery
    O'Connell, Rachel L.
    Stevens, Roger J. G.
    Harris, Paul A.
    Rusby, Jennifer E.
    BREAST, 2015, 24 (04): : 331 - 342
  • [34] Three-dimensional fast SE versus 3D GRE MR imaging of cervical spondylosis
    Lee, RR
    Melhem, ER
    RADIOLOGY, 1996, 201 : 1181 - 1181
  • [35] Three-dimensional imaging of moving ships with 3D motion based on AT-CT InSAR
    Tang, Li-Bo
    Li, Dao-Jing
    Hong, Wen
    Wu, Yi-Rong
    Ding, Chi-Biao
    Xi Tong Gong Cheng Yu Dian Zi Ji Shu/Systems Engineering and Electronics, 2008, 30 (09): : 1669 - 1673
  • [36] Three-dimensional imaging of living transplanted kidney vasculature by 3D color Doppler ultrasonography
    Xing, Jinfang
    Du, Lianfang
    ASIAN BIOMEDICINE, 2010, 4 (03) : 403 - 411
  • [37] Three-dimensional planing and correction of osteotomies in the forearm and the hand
    Schweizer, Andreas
    Furnstahl, Philipp
    Nagy, Ladislav
    THERAPEUTISCHE UMSCHAU, 2014, 71 (07) : 391 - 396
  • [38] y Comparison of Three-Dimensional Surface Imaging Systems Using Landmark Analysis
    Liberton, Denise K.
    Mishra, Rashmi
    Beach, Margaret
    Raznahan, Armin
    Gahl, William A.
    Manoli, Irini
    Lee, Janice S.
    JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (06) : 1869 - 1872
  • [39] Three-Dimensional CFD Analysis of the Hand and Forearm in Swimming
    Marinho, Daniel A.
    Silva, Antonio J.
    Reis, Victor M.
    Barbosa, Tiago M.
    Vilas-Boas, Joao P.
    Alves, Francisco B.
    Machado, Leandro
    Rouboa, Abel I.
    JOURNAL OF APPLIED BIOMECHANICS, 2011, 27 (01) : 74 - 80
  • [40] Comparison of two- and three-dimensional camera systems in laparoscopic performance: a novel 3D system with one camera
    Seong-Ho Kong
    Byung-Mo Oh
    Hongman Yoon
    Hye Seong Ahn
    Hyuk-Joon Lee
    Sun Geun Chung
    Norio Shiraishi
    Seigo Kitano
    Han-Kwang Yang
    Surgical Endoscopy, 2010, 24 : 1132 - 1143