Three-dimensional imaging of the forearm and hand: A comparison between two 3D imaging systems

被引:0
|
作者
van Ginkel, Laura [1 ,2 ]
Dupuis, Lotte [1 ]
Verhamme, Luc [3 ]
Hermans, Erik [1 ]
Maal, Thomas J. J. [3 ]
Stirler, Vincent [1 ]
机构
[1] Radboud Univ Nijmegen Med Ctr, Dept Trauma Surg, Nijmegen, Netherlands
[2] Univ Twente, Tech Med, Enschede, Netherlands
[3] Radboud Univ Nijmegen Med Ctr, Radboudumc 3D Lab, Nijmegen, Netherlands
来源
PLOS DIGITAL HEALTH | 2024年 / 3卷 / 04期
关键词
D O I
10.1371/journal.pdig.0000458
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The conventional treatment for distal radius fractures typically involves immobilization of the injured extremity using a conventional forearm cast. These casts do cause all sorts of discomfort during wear and impose life-style restrictions on the wearer. Personalized 3D printed splints, designed using three-dimensional (3D) imaging systems, might overcome these problems. To obtain a patient specific splint, commercially available 3D camera systems are utilized to capture patient extremities, generating 3D models for splint design. This study investigates the feasibility of utilizing a new camera system (SPENTYS) to capture 3D surface scans of the forearm for the design of 3D printed splints. In a prospective observational cohort study involving 17 healthy participants, we conducted repeated 3D imaging using both the new (SPENTYS) and a reference system (3dMD) to assess intersystem accuracy and repeatability. The intersystem accuracy of the SPENTYS system was determined by comparison of the 3D surface scans with the reference system (3dMD). Comparison of consecutive images acquired per device determined the repeatability. Feasibility was measured with system usability score questionnaires distributed among professionals. The mean absolute difference between the two systems was 0.44 mm (SD:0.25). The mean absolute difference of the repeatability of the reference -and the SPENTYS system was respectively 0.40 mm (SD: 0.30) and 0.53 mm (SD: 0.25). Both repeatability and intersystem differences were within the self-reported 1 mm. The workflow was considered easy and effective, emphasizing the potential of this approach within a workflow to obtain patient specific splint.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Three-dimensional (3D) ultrasound - a useful imaging technique in the assessment of neonatal brain
    Stanojevic, M
    Hafner, T
    Kurjak, A
    JOURNAL OF PERINATAL MEDICINE, 2002, 30 (01) : 74 - 83
  • [22] High Content Imaging (HCI) on Miniaturized Three-Dimensional (3D) Cell Cultures
    Joshi, Pranav
    Lee, Moo-Yeal
    BIOSENSORS-BASEL, 2015, 5 (04): : 768 - 790
  • [23] Comparison and Accuracy of Carotid Plaque Analysis Between Two- and Three-Dimensional Ultrasound Imaging
    Kingstone, Lysa Legault
    Shabana, Wael
    Thornhill, Rebecca
    White, Megan
    Lam, Joanna
    Currie, Geoff
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2014, 30 (03) : 123 - 130
  • [24] A comparison between two measurement configurations for full 3D GPR imaging
    Gennarelli, G.
    Catapano, I.
    Persico, R.
    Soldovieri, F.
    2014 8TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2014, : 3374 - 3377
  • [25] Three dimensional (3D) CT reconstruction in cancer imaging
    Rangarajan, V.
    INDIAN JOURNAL OF MEDICAL RESEARCH, 2013, 137 : 10 - 11
  • [26] Three-dimensional ultrasonography of normal fetal heart: Comparison with two-dimensional imaging
    Department of Radiology, McGill University, Jewish General Hospital, Montreal, Que., Canada
    不详
    不详
    不详
    不详
    J. Ultrasound Med., 6 (341-348):
  • [27] Three-dimensional ultrasonography of normal fetal heart: Comparison with two-dimensional imaging
    Levental, M
    Pretorius, DH
    Sklansky, MS
    Budorick, NE
    Nelson, TR
    Lou, K
    JOURNAL OF ULTRASOUND IN MEDICINE, 1998, 17 (06) : 341 - 348
  • [28] Three-Dimensional Surface-Imaging Systems
    Tzou, Chieh-Han John
    Artner, Nicole
    Kropatsch, Walter
    Frey, Manfred
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2013, 131 (04) : 668E - 670E
  • [29] Three-dimensional imaging
    Sinna, R
    Garson, S
    Delay, E
    ANNALS OF PLASTIC SURGERY, 2005, 55 (06) : 696 - 697
  • [30] Three-dimensional imaging
    Homma, S
    Hozumi, T
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2000, 17 (08): : 743 - 743