Reliability of Hand-Held Dynamometer Measurement for Thumb Palmar Abduction Strength in Carpal Tunnel Syndrome

被引:0
|
作者
Doi, Kazuteru [1 ]
Yasui, Noritada [1 ]
Isomura, Yuya [1 ]
Tagawa, Masafumi [1 ]
Hattori, Yasunori [1 ]
Sakamoto, Sotetsu [1 ]
机构
[1] Ogori Daiichi Gen Hosp, Ogori, Yamaguchi, Japan
关键词
Carpal tunnel syndrome; Hand-held dynamometer; Thumb palmar abduction; Bland-Altman analysis; Minimal detectable changes; INTERRATER RELIABILITY; MUSCLE; INDIVIDUALS; INTRARATER;
D O I
10.1142/S2424835525500262
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: In carpal tunnel syndrome (CTS), pain and sensory disturbance are the main symptoms, but thumb palmar abduction (TPA) paralysis cannot be ignored as a concurrent symptom. The reliable quantitative measurement of TPA power was not established. The purpose of this study was to report on the reliability of TPA strength measurements by the hand-held dynamometry (HHD) in large samples of CTS and its superiority over other tests, including grip, pinch powers, TPA angles and manual muscle testing, in terms of clinical progress indicators. Methods: We examined the relative and absolute reliabilities of the perioperative TPA strength measured by HHD (HHD-TPA) in 566 participants with CTS and the correlation coefficient between the HHD-TPA and other clinical tests. Results: The reliability of the HHD-TPA was intraclass correlation coefficients: 97% or higher. The Bland-Altman absolute reliability showed a random pattern of bias, and the minimal detectable changes (MDC) of the inter-rater and intra-rater reliabilities indicated 9.0 N and 7.0 N individually. The HHD-TPA showed statistically significant recoveries between perioperative stages; however, the mean difference larger than the MDC was recognised only between the preoperative and 12-month postoperative stages by intra-rater comparison. More individual patients showed recovery of HHD-TPA beyond the MDC when the same examiner continuously measured HHD-TPA than when multiple examiners continuously measured HHD-TPA. Grip strength and pinch strength measurements showed a strong correlation with HHD-TPA and did not show statistically significant improvement during the perioperative period. Conclusions: HHD-TPA is the most reliable method for quantifying muscle strength in the perioperative course of TPA force in CTS. HHD-TPA is a more reliable assessment of CTS motor recovery when measured consistently for each patient by the same hand therapist.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] A Comparison of the Reliability of Make Versus Break Testing in Measuring Palmar Abduction Strength of the Thumb
    Lim, J. X.
    Toh, R. X.
    Chook, S. K. H.
    Sebastin, S. J.
    Karjalainen, T.
    JOURNAL OF HAND AND MICROSURGERY, 2014, 6 (01) : 8 - 12
  • [42] MUSCLE STRENGTH EVALUATED USING THE HAND-HELD DYNAMOMETER MICROFET2 IN OLDER ADULTS: A RELIABILITY STUDY
    Locquet, M.
    Beaudart, C.
    Reginster, J. -Y.
    Bruyere, O.
    Croisier, J. -L.
    OSTEOPOROSIS INTERNATIONAL, 2020, 31 (SUPPL 1) : S301 - S302
  • [43] COMPARISON OF A HAND-HELD AND FIXED DYNAMOMETER IN MEASURING STRENGTH OF PATIENTS WITH NEUROMUSCULAR DISEASE
    BRINKMANN, JR
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1994, 19 (02): : 100 - 104
  • [44] Measuring muscular strength of the lower limbs by hand-held dynamometer: A standard protocol
    S. Bandinelli
    E. Benvenuti
    I. Del Lungo
    M. Baccini
    F. Benvenuti
    A. Di Iorio
    L. Ferrucci
    Aging Clinical and Experimental Research, 1999, 11 : 287 - 293
  • [45] Measuring muscular strength of the lower limbs by hand-held dynamometer: A standard protocol
    Bandinelli, S
    Benvenuti, E
    Del Lungo, I
    Baccini, M
    Benvenuti, F
    Di Iorio, A
    Ferrucci, L
    AGING-CLINICAL AND EXPERIMENTAL RESEARCH, 1999, 11 (05) : 287 - 293
  • [46] EVALUATION OF A HAND-HELD DYNAMOMETER FOR MEASURING MUSCLE STRENGTH UNDER FIELD CONDITIONS
    METCALF, WK
    STUBERG, WA
    JOURNAL OF PHYSIOLOGY-LONDON, 1986, 380 : P64 - P64
  • [47] COMPARATIVE STUDY ON THE ASSESSMENT OF THE STRENGTH OF THE KNEE EXTENSOR AND FLEXOR MUSCLES BY HAND-HELD DYNAMOMETER AND ISOKINETIC DYNAMOMETER
    Muff, Guillaume
    Masat, Julien
    Lecocq, Jehan
    Meyer, Alain
    Isner-Horobeti, Marie-Eve
    ACTA PHYSIOLOGICA, 2015, 214 : 46 - 46
  • [48] Reliability of Isometric Knee Extension Muscle Strength Measurement Using a Hand-held Dynamometer with a Belt: A Study of Test-retest Reliability in Healthy Elderly Subjects
    Katoh, Munenori
    Isozaki, Koji
    Sakanoue, Noboru
    Miyahara, Takuya
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2010, 22 (04) : 359 - 363
  • [49] Test-retest Reliability of Isometric Knee Extension Muscle Strength Measurement using a Hand-held Dynamometer and a Belt: Study of Hemiplegic Patients
    Katoh, Munenori
    Asuma, Hitomi
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2011, 23 (01) : 25 - 28
  • [50] A comparison of 3 hand-held dynamometers used to measure hip abduction strength
    Fenter, PC
    Bellew, JW
    Pitts, T
    Kay, R
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2003, 17 (03) : 531 - 535