Reliability of Hand-Held Dynamometer Measurement for Thumb Palmar Abduction Strength in Carpal Tunnel Syndrome

被引:0
|
作者
Doi, Kazuteru [1 ]
Yasui, Noritada [1 ]
Isomura, Yuya [1 ]
Tagawa, Masafumi [1 ]
Hattori, Yasunori [1 ]
Sakamoto, Sotetsu [1 ]
机构
[1] Ogori Daiichi Gen Hosp, Ogori, Yamaguchi, Japan
关键词
Carpal tunnel syndrome; Hand-held dynamometer; Thumb palmar abduction; Bland-Altman analysis; Minimal detectable changes; INTERRATER RELIABILITY; MUSCLE; INDIVIDUALS; INTRARATER;
D O I
10.1142/S2424835525500262
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: In carpal tunnel syndrome (CTS), pain and sensory disturbance are the main symptoms, but thumb palmar abduction (TPA) paralysis cannot be ignored as a concurrent symptom. The reliable quantitative measurement of TPA power was not established. The purpose of this study was to report on the reliability of TPA strength measurements by the hand-held dynamometry (HHD) in large samples of CTS and its superiority over other tests, including grip, pinch powers, TPA angles and manual muscle testing, in terms of clinical progress indicators. Methods: We examined the relative and absolute reliabilities of the perioperative TPA strength measured by HHD (HHD-TPA) in 566 participants with CTS and the correlation coefficient between the HHD-TPA and other clinical tests. Results: The reliability of the HHD-TPA was intraclass correlation coefficients: 97% or higher. The Bland-Altman absolute reliability showed a random pattern of bias, and the minimal detectable changes (MDC) of the inter-rater and intra-rater reliabilities indicated 9.0 N and 7.0 N individually. The HHD-TPA showed statistically significant recoveries between perioperative stages; however, the mean difference larger than the MDC was recognised only between the preoperative and 12-month postoperative stages by intra-rater comparison. More individual patients showed recovery of HHD-TPA beyond the MDC when the same examiner continuously measured HHD-TPA than when multiple examiners continuously measured HHD-TPA. Grip strength and pinch strength measurements showed a strong correlation with HHD-TPA and did not show statistically significant improvement during the perioperative period. Conclusions: HHD-TPA is the most reliable method for quantifying muscle strength in the perioperative course of TPA force in CTS. HHD-TPA is a more reliable assessment of CTS motor recovery when measured consistently for each patient by the same hand therapist.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Thumb strength affected by carpal tunnel syndrome
    Li, ZM
    Harkness, DA
    Goitz, RJ
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) : 320 - 326
  • [22] Reliability of hand-held dynamometer in measuring gluteus medius isometric muscle strength in healthy population
    Soomro, Rabail Rani
    Karimi, Hossein
    Gillani, Syed Amir
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2022, 38 (05) : 1238 - 1242
  • [23] INTRATESTER RELIABILITY OF STRENGTH TESTING IN DYSTROPHIC AND NORMAL-CHILDREN USING A HAND-HELD DYNAMOMETER
    STUBERG, WA
    METCALF, WK
    PHYSICAL THERAPY, 1986, 66 (05): : 800 - 800
  • [24] Reliability and validity of the hand-held dynamometer "NOD": a new instrument for assessment of isometric grip strength
    Sartorio, Francesco
    Lippi, Lorenzo
    Vercelli, Stefano
    Gallo, Federica
    Zanin, Davide
    Bergesio, Sara
    de Sire, Alessandro
    Invernizzi, Marco
    BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)
  • [25] Reliability of Hand-Held Dynamometer for assessing Isometric Lumbar Muscles Strength in Asymptomatic Healthy Population
    Tanveer, Fahad
    Arslan, Syed Asadullah
    Darain, Haider
    Ahmad, Ashfaq
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2021, 37 (02) : 461 - 465
  • [26] RELIABILITY, COMPARABILITY, AND VALIDITY OF FOOT INVERSION AND EVERSION STRENGTH MEASUREMENTS USING A HAND-HELD DYNAMOMETER
    Alfuth, Martin
    Murielle, Magali
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2016, 11 (01): : 72 - 84
  • [27] Clinical relevance commentary in response to: Intrarater and inter-rater reliability of a handheld dynamometric technique to quantify palmar thumb abduction strength in individuals with and without carpal tunnel syndrome
    Szekeres, Mike
    JOURNAL OF HAND THERAPY, 2018, 31 (04) : 562 - 563
  • [28] Strength of the intrinsic muscles of the hand measured with a hand-held dynamometer: Reliability in patients with ulnar and median nerve paralysis
    Schreuders, TAR
    Roebroeck, M
    Van der Kar, TJM
    Soeters, JNM
    Hovius, SER
    Stam, HJ
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2000, 25B (06): : 560 - 565
  • [29] Reliability of the Hand-Held Dynamometer During Hip Isometric Strength Testing Both With and Without a Stabilization Strap
    Beard, Megan Q.
    Boland, Samantha A.
    Gribble, Phillip A.
    INTERNATIONAL JOURNAL OF ATHLETIC THERAPY & TRAINING, 2020, 25 (01): : 37 - 42
  • [30] Reliability of measuring hip abductor strength following total knee arthroplasty using a hand-held dynamometer
    Schache, Margaret B.
    McClelland, Jodie A.
    Webster, Kate E.
    DISABILITY AND REHABILITATION, 2016, 38 (06) : 597 - 600