The Mechanical Properties of Orthodontic Aligners of Clear Aligner After Intraoral Use in Different Time Periods

被引:0
|
作者
Siotou, Kalliopi [1 ]
Chountalas, Theofanis [2 ]
Katsavrias, Athanasios [3 ]
Siotos, Charalampos [4 ]
Mpalias, Konstantinos [3 ]
Semitekolos, Dionysios [3 ]
Charitidis, Constantinos [3 ]
Tsolakis, Apostolos I. [1 ]
机构
[1] Natl & Kapodistrian Univ Athens, Dept Orthodont, Athens, Greece
[2] Natl Tech Univ Athens, Mech Engn Sch, Dept Lab Heterogeneous Mixtures & Combust Syst, Athens, Greece
[3] Natl Tech Univ Athens, Chem Engn Sch, Res Lab Adv Composite Nano Mat & Nanotechnol, Zografos, Greece
[4] Rush Univ, Med Ctr, Div Plast & Reconstruct Surg, Chicago, IL USA
关键词
ageing; clear aligner; intraoral; mechanical properties; orthodontic aligners; FORCE DELIVERY PROPERTIES; BITE FORCE; EFFICIENCY;
D O I
10.1111/ocr.12867
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveAlthough the technique of orthodontic aligners has risen in popularity, their mechanical properties have not been thoroughly investigated. The aim of this study was to evaluate the mechanical properties of the orthodontic aligners Clear Aligner after intraoral use for 7, 10 and 14 days, and to compare them with as-received aligners (0 days). It was also sought to examine the properties of the unprocessed raw material (polyethylene glycol terephthalate) used to manufacture these aligners.Materials/MethodsThirty-two aligners by four patients were evaluated and studied at 0, 7, 10, 14 days of use. Each aligner was divided into three segments (two posterior and one anterior), which resulted in 96 samples. Also, 16 samples of unprocessed material were studied. For all samples, elastic modulus, ultimate tensile stress (UTS) and yield stress were calculated by conducting tensile testing. Additionally, material hardness was tested. The two-tailed Mann-Whitney test was performed, having set the level of significance at p = 0.05.ResultsAnalysis of the measurements indicated a statistically significant decrease in elastic modulus between days 0 and 14 of use, of UTS between days 0 and 7, 7 and 10, and of yield stress between days 0 and 7. For hardness, in every period, posterior segments demonstrated significantly higher values than anterior segments. All properties of the unprocessed material were statistically significantly higher than the processed samples.ConclusionsThe unprocessed material presented significant differences in every property tested in comparison to the processed aligners. The processed material showed further deterioration over time during use. The present study provides evidence that thermoforming and ageing affect the mechanical properties of the aligners.
引用
收藏
页码:253 / 260
页数:8
相关论文
共 50 条
  • [21] An in vivo evaluation of clear aligners for optimal orthodontic force and movement to determine high-efficacy and periodontal-friendly aligner staging
    Wang, Yuru
    Chen, Jie
    Qin, Siwen
    Han, Xue
    Liao, Lijun
    Sima, Xiutian
    Guo, Weihua
    HELIYON, 2023, 9 (04)
  • [22] Wear resistance of orthodontic attachments: a comparative analysis of different composite resins in clear aligner therapy
    Irmak Ocak
    Hande Gorucu-Coskuner
    Muge Aksu
    Clinical Oral Investigations, 29 (5)
  • [23] Comparative evaluation of physical and mechanical properties of clear aligners - a systematic review
    Srinivasan, Bhadrinath
    Padmanabhan, Sridevi
    Srinivasan, Sivakumar
    EVIDENCE-BASED DENTISTRY, 2024, 25 (01) : 53 - 53
  • [24] Assessment of Awareness and Perceptions of Healthcare Professional Graduates Regarding the Use of Clear Aligners in Orthodontic Treatment
    Shivlani, Vinus
    Niranjane, Priyanka
    Paul, Priyanka
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)
  • [25] Effects of intraoral aging on mechanical properties of directly printed aligners vs. thermoformed aligners: an in vivo prospective investigation
    Sayahpour, Babak
    Zinelis, Spiros
    Polychronis, Georgios
    Eliades, Theodore
    Goteni, Malcolm
    Kopp, Stefan
    Eslami, Sara
    EUROPEAN JOURNAL OF ORTHODONTICS, 2024, 46 (01)
  • [26] Thermal and mechanical characterization of thermoplastic orthodontic aligners discs after molding process
    Pratto, Isabella
    Agner Busato, Mauro Carlos
    Stival Bittencourt, Paulo Rodrigo
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 126
  • [27] Comparison of mechanical properties of 3-dimensional printed and thermoformed orthodontic aligners
    Shirey, Nic
    Mendonca, Gustavo
    Groth, Christian
    Kim-Berman, Hera
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2023, 163 (05) : 720 - 728
  • [28] Effects of thermoforming on the physical and mechanical properties of thermoplastic materials for transparent orthodontic aligners
    Ryu, Jeong-Hyun
    Kwon, Jae-Sung
    Jiang, Heng Bo
    Cha, Jung-Yul
    Kim, Kwang-Mahn
    KOREAN JOURNAL OF ORTHODONTICS, 2018, 48 (05) : 316 - +
  • [29] Comparative Assessment of Orthodontic and Aesthetic Outcomes after Orthognathic Surgery with Clear Aligner or Fixed Appliance Therapy
    Liou, Yu-Jia
    Chen, Pin-Ru
    Tsai, Tzong-Yueh
    Lin, Susie
    Chou, Pang-Yun
    Lo, Chiu-Mei
    Chen, Yu-Ray
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2024, 154 (01) : 162 - 172
  • [30] Electrical and mechanical properties of composite insulators after different operation periods
    School of Electrical Engineering, Wuhan University, Wuhan 430072, China
    不详
    Gaodianya Jishu, 2008, 5 (1017-1021):