The Mechanical Properties of Orthodontic Aligners of Clear Aligner After Intraoral Use in Different Time Periods

被引:0
|
作者
Siotou, Kalliopi [1 ]
Chountalas, Theofanis [2 ]
Katsavrias, Athanasios [3 ]
Siotos, Charalampos [4 ]
Mpalias, Konstantinos [3 ]
Semitekolos, Dionysios [3 ]
Charitidis, Constantinos [3 ]
Tsolakis, Apostolos I. [1 ]
机构
[1] Natl & Kapodistrian Univ Athens, Dept Orthodont, Athens, Greece
[2] Natl Tech Univ Athens, Mech Engn Sch, Dept Lab Heterogeneous Mixtures & Combust Syst, Athens, Greece
[3] Natl Tech Univ Athens, Chem Engn Sch, Res Lab Adv Composite Nano Mat & Nanotechnol, Zografos, Greece
[4] Rush Univ, Med Ctr, Div Plast & Reconstruct Surg, Chicago, IL USA
关键词
ageing; clear aligner; intraoral; mechanical properties; orthodontic aligners; FORCE DELIVERY PROPERTIES; BITE FORCE; EFFICIENCY;
D O I
10.1111/ocr.12867
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveAlthough the technique of orthodontic aligners has risen in popularity, their mechanical properties have not been thoroughly investigated. The aim of this study was to evaluate the mechanical properties of the orthodontic aligners Clear Aligner after intraoral use for 7, 10 and 14 days, and to compare them with as-received aligners (0 days). It was also sought to examine the properties of the unprocessed raw material (polyethylene glycol terephthalate) used to manufacture these aligners.Materials/MethodsThirty-two aligners by four patients were evaluated and studied at 0, 7, 10, 14 days of use. Each aligner was divided into three segments (two posterior and one anterior), which resulted in 96 samples. Also, 16 samples of unprocessed material were studied. For all samples, elastic modulus, ultimate tensile stress (UTS) and yield stress were calculated by conducting tensile testing. Additionally, material hardness was tested. The two-tailed Mann-Whitney test was performed, having set the level of significance at p = 0.05.ResultsAnalysis of the measurements indicated a statistically significant decrease in elastic modulus between days 0 and 14 of use, of UTS between days 0 and 7, 7 and 10, and of yield stress between days 0 and 7. For hardness, in every period, posterior segments demonstrated significantly higher values than anterior segments. All properties of the unprocessed material were statistically significantly higher than the processed samples.ConclusionsThe unprocessed material presented significant differences in every property tested in comparison to the processed aligners. The processed material showed further deterioration over time during use. The present study provides evidence that thermoforming and ageing affect the mechanical properties of the aligners.
引用
收藏
页码:253 / 260
页数:8
相关论文
共 50 条
  • [41] Discussion: Comparative Assessment of Orthodontic and Aesthetic Outcomes after Orthognathic Surgery with Clear Aligner or Fixed Appliance Therapy
    Susarla, Srinivas M.
    Sheller, Barbara
    Kapadia, Hitesh
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2024, 154 (01) : 173 - 174
  • [42] Mechanical and geometric properties of thermoformed and 3D printed clear dental aligners
    Jindal, Prashant
    Juneja, Mamta
    Siena, Francesco Luke
    Bajaj, Divya
    Breedon, Philip
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2019, 156 (05) : 694 - 701
  • [43] Study on the Antibacterial Properties and Optical Characteristics of Clear Orthodontic Aligners Coated With Zinc Oxide and Magnesium Oxide Nanoparticles
    Gharibnavaz, Mahnaz
    Arash, Valiollah
    Pournajaf, Abazar
    Najafi, Farhood
    Kamel, Manouchehr Rahmati
    Seyedmajidi, Seyedali
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2025,
  • [44] Preadolescents' Smile Outcomes after Two Different Orthodontic Treatments: Traditional Interceptive Therapy with Rapid Maxillary Expansion (RME)/Schwarz Plate and Clear Aligners
    Rozzi, Matteo
    Mucedero, Manuela
    Fanelli, Silvia
    Bollero, Patrizio
    Cozza, Paola
    APPLIED SCIENCES-BASEL, 2024, 14 (20):
  • [45] Optical properties of orthodontic aligners—spectrophotometry analysis of three types before and after aging
    Luca Lombardo
    Angela Arreghini
    Roberta Maccarrone
    Anna Bianchi
    Santo Scalia
    Giuseppe Siciliani
    Progress in Orthodontics, 16
  • [46] Scanning electron microscopy analysis of the growth of dental plaque on the surfaces of removable orthodontic aligners after the use of different cleaning methods
    Levrini, Luca
    Novara, Francesca
    Margherini, Silvia
    Tenconi, Camilla
    Raspanti, Mario
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2015, 7 : 125 - 131
  • [47] The effect of time on mechanical properties of biocompatible photopolymer resins used for fabrication of clear dental aligners (vol 119, 104494, 2021)
    Milovanovic, Aleksa
    Sedmak, Aleksandar
    Golubovic, Zorana
    Mihajlovic, Ksenija Zelic
    Zurkic, Aleksandar
    Trajkovic, Isaak
    Milosevic, Milos
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 120
  • [48] Effects of different tooth movement patterns and aligner thicknesses on maxillary arch expansion with clear aligners: a three-dimensional finite element study
    Li, Na
    Wang, ChunJuan
    Yang, Min
    Chen, DingGen
    Tang, MingYuan
    Li, DaoKun
    Qiu, ShengLei
    Chen, Qi
    Feng, Yi
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [49] An evaluation of root resorption associated with the use of photobiomodulation during orthodontic treatment with clear aligners: a retrospective cohort pilot study
    Rossi, Antonio
    Lagravere-Vich, Manuel
    Heo, Giseon
    Major, Paul W.
    El-Bialy, Tarek
    ANGLE ORTHODONTIST, 2024, 94 (03) : 294 - 302
  • [50] Elemental, microstructural, and mechanical characterization of high gold orthodontic brackets after intraoral aging
    Hersche, Sepp
    Sifakakis, Iosif
    Zinelis, Spiros
    Eliades, Theodore
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2017, 62 (01): : 97 - 102