Precise Acetabular Prosthesis Positioning Using a Novel Robot-Assisted Total Hip Arthroplasty System: A Multicenter, Randomized Controlled Trial

被引:0
|
作者
Geng, Xiao [1 ,2 ]
Dong, Ziyang [1 ,2 ]
Li, Yang [1 ,2 ]
Zhao, Minwei [1 ,2 ]
Liu, Yanqing [1 ,2 ]
Li, Zijian [1 ,2 ]
Cai, Hong [1 ,2 ]
Zhang, Ming [3 ]
Yan, Xinfeng [3 ]
Sun, Zhiwen [4 ]
Lv, Xin [4 ]
Guo, Feng [4 ]
Li, Feng [1 ,2 ]
Tian, Hua [1 ,2 ]
机构
[1] Peking Univ Third Hosp, Dept Orthopaed, Beijing, Peoples R China
[2] Engn Res Ctr Bone & Joint Precis Med, Beijing, Peoples R China
[3] Shandong First Med Univ, Affiliated Hosp 1, Shandong Prov Qianfoshan Hosp, Dept Orthopaed, Jinan, Peoples R China
[4] Chifeng Municipal Hosp, Dept Orthopaed, Chifeng, Peoples R China
关键词
acetabular prosthesis positioning; anteversion angle; inclination angle; robotic surgery; total hip arthroplasty; DISLOCATION; ARTHRITIS;
D O I
10.1111/os.14277
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective Total hip arthroplasty (THA) is currently one of the most effective treatment methods for end-stage hip joint disease, and its long-term effectiveness largely depends on the accurate placement of the acetabular prosthesis. In conventional surgery, the placement of the acetabular prosthesis mainly relies on the surgeon's clinical experience and surgical techniques. To further improve the accuracy of prosthesis placement, a new robotic system for THA is designed. The purpose of this study is to verify the effectiveness and safety of THA assisted by this robotic system. Method A multicenter, prospective, randomized controlled, superiority study design was adopted with statistical methods of t test and Chi-squared test. Participants undergoing primary THA have been enrolled in three centers of joint surgery in China since July 17, 2023. Robotic THA was operated in the experimental group, and conventional instruments were used in the control group. The primary outcome is the proportion of anteversion and inclination angles in the safe zone. The secondary outcomes include operation time, WOMAC score, Harris score, SF-36 health questionnaire, dislocation rate of hip joint, and rates of adverse events and serious adverse events. Results A total of 138 patients were included in this study. The proportion of both anteversion and inclination angles in the safe zone was 92.2% in the experimental group and 50.8% in the control group, with significant difference (p < 0.01). The average operation time in the experimental group and control group was 116.4 and 80.5 min respectively, with significant difference (p < 0.01). There was no significant difference in WOMAC score, Harris score, and SF-36 between the two groups (6 +/- 2) weeks after operation (p > 0.05). The dislocation rate of hip joint in the experimental group and control group were 3.0% and 1.5%, respectively, without significant difference (p > 0.05). The rate of adverse events and severe adverse events in the experimental group and control group also showed no significant difference (p > 0.05). No adverse events or serious adverse events were judged to be "definitely related" to the experimental instruments. Conclusion Robotic THA could prolong the operation time within an acceptable range, but more precise acetabular prosthesis positioning could be obtained when compared with conventional surgery. Besides, no significant difference was found in function scores, dislocation rate or other adverse events, which indicates that this new robot system shows both good effectiveness and safety in THA.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Radiographic evaluation of robot-assisted versus manual total hip arthroplasty: a multicenter randomized controlled trial
    Zhang, Xianzuo
    Shen, Xianyue
    Zhang, Rongwei
    Chen, Mo
    Ma, Ruixiang
    Zhang, Zian
    Zhang, Haining
    Yang, Bo
    Zhu, Chen
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2024, 25 (01)
  • [2] The learning curve of a novel seven-axis robot-assisted total hip arthroplasty system: a randomized controlled trial
    Sun, Haocheng
    Lu, Hanpeng
    Xiao, Qiang
    Ding, Zichuan
    Luo, Zeyu
    Zhou, Zongke
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [3] Computer-Assisted Total Hip Arthroplasty Improves Acetabular Prosthesis Placement Accuracy: A Multicenter, Randomized Controlled Clinical Study
    Zhou, Ge
    Geng, Xiao
    Zhang, Ming
    Sun, Zhiwen
    Li, Feng
    Zhao, Minwei
    Tian, Hua
    ORTHOPAEDIC SURGERY, 2024, 16 (12) : 3078 - 3087
  • [4] Robot-assisted total hip arthroplasty
    Banerjee, Samik
    Cherian, Jeffery J.
    Elmallah, Randa K.
    Pierce, Todd P.
    Jauregui, Julio J.
    Mont, Michael A.
    EXPERT REVIEW OF MEDICAL DEVICES, 2016, 13 (01) : 47 - 56
  • [5] Precise acetabular positioning, discrepancy in leg length, and hip offset using a new seven-axis robot-assisted total hip arthroplasty system requires no learning curve: a retrospective study
    Tian, Run
    Duan, Xudong
    Kong, Ning
    Wang, Kunzheng
    Yang, Pei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [6] Precise acetabular positioning, discrepancy in leg length, and hip offset using a new seven-axis robot-assisted total hip arthroplasty system requires no learning curve: a retrospective study
    Run Tian
    Xudong Duan
    Ning Kong
    Kunzheng Wang
    Pei Yang
    Journal of Orthopaedic Surgery and Research, 18
  • [7] Acetabular Component Positioning in Total Hip Arthroplasty With and Without a Computer-Assisted System: A Prospective, Randomized and Controlled Study
    Gurgel, Henrique M. C.
    Croci, Alberto T.
    Cabrita, Henrique A. B. A.
    Vicente, Jose Ricardo N.
    Leonhardt, Marcos C.
    Rodrigues, Joao Carlos
    JOURNAL OF ARTHROPLASTY, 2014, 29 (01): : 167 - 171
  • [8] A commentary on 'A new designed full process coverage robot-assisted total hip arthroplasty: a multicenter randomized clinical trial'
    Yan, Zheng
    Xu, Yan
    Wu, Lianguo
    INTERNATIONAL JOURNAL OF SURGERY, 2024, 110 (08) : 5216 - 5217
  • [9] Comparison of Three-Dimensional Planning-Assisted and Conventional Acetabular Cup Positioning in Total Hip Arthroplasty A Randomized Controlled Trial
    Sariali, Elhadi
    Boukhelifa, Nadia
    Catonne, Yves
    Moussellard, Hugues Pascal
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (02): : 108 - 116
  • [10] Robot-Assisted Total Hip Arthroplasty for Arthrodesed Hips
    Chai, Wei
    Kong, Xiangpeng
    Yang, Minzhi
    Puah, Ken Lee
    Tang, Peifu
    Chen, Jiying
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2020, 16 : 357 - 368