Computer-Assisted Total Hip Arthroplasty Improves Acetabular Prosthesis Placement Accuracy: A Multicenter, Randomized Controlled Clinical Study

被引:0
|
作者
Zhou, Ge [1 ,2 ]
Geng, Xiao [1 ,2 ]
Zhang, Ming [3 ]
Sun, Zhiwen [4 ]
Li, Feng [1 ,2 ]
Zhao, Minwei [1 ,2 ]
Tian, Hua [1 ,2 ]
机构
[1] Peking Univ Third Hosp, Dept Orthoped, Beijing, Peoples R China
[2] Engn Res Ctr Bone & Joint Precis Med, Beijing, Peoples R China
[3] Shandong First Med Univ, Shandong Prov Qianfoshan Hosp, Affiliated Hosp 1, Jinan, Peoples R China
[4] Chifeng Municipal Hosp, Chifeng, Peoples R China
关键词
Accuracy; Computer-Assisted Navigation; Cup Position; Safe Zone; Total Hip Arthroplasty; SAFE ZONE; POLYETHYLENE WEAR; NAVIGATION; DISLOCATION; REVISION;
D O I
10.1111/os.14251
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: The long-term effectiveness of total hip arthroplasty (THA) largely depends on the accuracy of acetabular prosthesis placement. To improve the accuracy of acetabular prosthesis placement, we utilized a new surgical navigation system: visual treatment solution (VTS). The purpose of this study was to verify the efficacy and safety of this system in assisting THA. Methods: This was a prospective, multicenter, randomized controlled trial. One hundred and twenty-four patients undergoing primary THAs were included. The experimental group underwent VTS-assisted THA, and the control group underwent traditional surgical techniques. The main efficacy evaluation indicators were the proportion of anteversion and inclination angles in the Lewinnek safe zone, and secondary evaluation indicators included operation time, Western Ontario and McMaster University Osteoarthritis index (WOMAC) score, Harris score, short-form-36 (SF-36) score, and hip dislocation rate. Statistical analysis was performed mainly by t-test and chi-square test. Results: The proportion of both anteversion and inclination angles in the safe zone was 93.1% in the experimental group and 50.9% in the control group; the difference was significant (p < 0.01). The average operation time was 112.5 min in the experimental group and 92.6 min in the control group; the difference was significant (p < 0.01). There were no significant differences in WOMAC score, Harris score, or SF-36 score between the experimental and control groups at 3 months after the operation (p > 0.05). The dislocation rate was 0% in the experimental group and 1.6% in the control group; the difference was not significant (p > 0.05). Conclusion: VTS-assisted THA can significantly improve the accuracy of acetabular prosthesis placement. However, there were no differences in short-term clinical outcomes or dislocation rates between the two groups.
引用
收藏
页码:3078 / 3087
页数:10
相关论文
共 50 条
  • [1] Accuracy of computer-assisted cup placement in total hip arthroplasty
    Jolles, BM
    Genoud, P
    Hoffmeyer, P
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 301 - 305
  • [2] Direct Anatomic Registration in Computer-Assisted Total Hip Arthroplasty Improves Accuracy of Acetabular Cup Alignment
    Patamarat, Apisit
    Laoruengthana, Artit
    Kitcharanant, Nitchanant
    Khantasit, Jakkaphong
    Thremthakanpon, Witoon
    ARTHROPLASTY TODAY, 2023, 21
  • [3] Acetabular Component Positioning in Total Hip Arthroplasty With and Without a Computer-Assisted System: A Prospective, Randomized and Controlled Study
    Gurgel, Henrique M. C.
    Croci, Alberto T.
    Cabrita, Henrique A. B. A.
    Vicente, Jose Ricardo N.
    Leonhardt, Marcos C.
    Rodrigues, Joao Carlos
    JOURNAL OF ARTHROPLASTY, 2014, 29 (01): : 167 - 171
  • [4] Computer-assisted cup placement techniques in total hip arthroplasty improve accuracy of placement
    Jolles, BM
    Genoud, P
    Hoffmeyer, P
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) : 174 - 179
  • [5] Computer-assisted surgery for acetabular cup positioning in total hip arthroplasty: comparative prospective randomized study
    Parratte, S.
    Argenson, J.-N.
    Flecher, X.
    Aubaniac, J.-M.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2007, 93 (03): : 238 - 246
  • [6] Accuracy of Acetabular Component Positioning Using Computer-assisted Navigation in Direct Anterior Total Hip Arthroplasty
    Bradley, Michael P.
    Benson, Jessica R.
    Muir, Jeffrey M.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (04)
  • [7] Computer-assisted placement technique in hip resurfacing arthroplasty: improvement in accuracy?
    S. Krüger
    P. Y. Zambelli
    P.-F. Leyvraz
    B. M. Jolles
    International Orthopaedics, 2009, 33 : 27 - 33
  • [8] Computer-assisted placement technique in hip resurfacing arthroplasty: improvement in accuracy?
    Krueger, S.
    Zambelli, P. Y.
    Leyvraz, P. -F.
    Jolles, B. M.
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (01) : 27 - 33
  • [9] Precise Acetabular Prosthesis Positioning Using a Novel Robot-Assisted Total Hip Arthroplasty System: A Multicenter, Randomized Controlled Trial
    Geng, Xiao
    Dong, Ziyang
    Li, Yang
    Zhao, Minwei
    Liu, Yanqing
    Li, Zijian
    Cai, Hong
    Zhang, Ming
    Yan, Xinfeng
    Sun, Zhiwen
    Lv, Xin
    Guo, Feng
    Li, Feng
    Tian, Hua
    ORTHOPAEDIC SURGERY, 2024,
  • [10] Evaluation of cup placement accuracy in computer assisted total hip arthroplasty
    Kaneta, Hiroki
    Shoji, Takeshi
    Ueki, Shinichi
    Morita, Hiroyuki
    Kozuma, Yosuke
    Adachi, Nobuo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2025, 145 (01)