Direct Anatomic Registration in Computer-Assisted Total Hip Arthroplasty Improves Accuracy of Acetabular Cup Alignment

被引:2
|
作者
Patamarat, Apisit [1 ]
Laoruengthana, Artit [2 ,6 ]
Kitcharanant, Nitchanant [3 ]
Khantasit, Jakkaphong [4 ]
Thremthakanpon, Witoon [5 ]
机构
[1] Phra Nakhon Si Ayutthaya Hosp, Dept Orthopaed Surg, Ayutthaya, Thailand
[2] Naresuan Univ, Fac Med, Dept Orthopaed, Phitsanulok, Thailand
[3] Chiang Mai Univ, Fac Med, Dept Orthopaed, Chiang Mai, Thailand
[4] Phra Nakhon Si Ayutthaya Hosp, Dept Nursing, Ayutthaya, Thailand
[5] Phitsanulok Hosp, Dept Orthopaed, Phitsanulok, Thailand
[6] Naresuan Univ, Fac Med, Dept Orthopaed, 99 Moo Thapho, Phitsanulok 65000, Thailand
来源
ARTHROPLASTY TODAY | 2023年 / 21卷
关键词
Anatomical registration; Computer-assisted; Acetabular cup alignment; Total hip arthroplasty; ANTERIOR PELVIC PLANE; POLYETHYLENE WEAR; NAVIGATION; REPLACEMENT; ORIENTATION; POSITION; TILT;
D O I
10.1016/j.artd.2023.101148
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Computer-assisted total hip arthroplasty using direct anatomic registration (DAR) with acetabular center axis software is an alternative method to the indirect anterior pelvic plane method. The software maps the center of hip rotation and orientation of the native acetabulum in 3 dimensions. This study aimed to evaluate the accuracy of acetabular cup alignment using DAR navigation combined with a mechanical guide device (MGD).Methods: This prospective nonrandomized controlled study included 106 patients who underwent primary cementless total hip arthroplasty through the posterolateral approach. Fifty-four patients in the study group underwent DAR combined with MGD, whereas 52 patients underwent MGD only for acetabular cup positioning. Plain radiographs of both hips and computerized tomographic scans were obtained 2 months postoperatively for the evaluation of acetabular cup inclination and anteversion, respectively.Results: The acetabular cup alignment in the study group was within the Lewinnek safe zone more than that in the control group (81.5% vs 59.6%, P < .05). The study group had a mean inclination angle of 43.88(degrees degrees) (standard deviation [SD] 5.38) and anteversion angle of 12.82(degrees)(SD 5.99), whereas the control group had 41.10(degrees)(SD 6.79) and 12.82(degrees) (SD 9.53), respectively. There were no significant differences in estimated blood loss, length of stay, and Harris hip scores at preoperative and 3 and 6 months postoperatively, except for the operative time, which was longer in the study group (P < .01). There was 1 posterior hip dislocation in each group.Conclusions: DAR navigation combined with MGD provides better accuracy for acetabular cup positioning within the Lewinnek safe zone compared with the conventional technique.(c) 2023 The Authors. Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Accuracy of computer-assisted cup placement in total hip arthroplasty
    Jolles, BM
    Genoud, P
    Hoffmeyer, P
    [J]. CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 301 - 305
  • [2] Accuracy of Acetabular Component Positioning Using Computer-assisted Navigation in Direct Anterior Total Hip Arthroplasty
    Bradley, Michael P.
    Benson, Jessica R.
    Muir, Jeffrey M.
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (04)
  • [3] Computer-assisted cup placement techniques in total hip arthroplasty improve accuracy of placement
    Jolles, BM
    Genoud, P
    Hoffmeyer, P
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) : 174 - 179
  • [4] Computer-assisted surgery for acetabular cup positioning in total hip arthroplasty: comparative prospective randomized study
    Parratte, S.
    Argenson, J.-N.
    Flecher, X.
    Aubaniac, J.-M.
    [J]. REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2007, 93 (03): : 238 - 246
  • [5] Computer-assisted stereotaxic navigation improves the accuracy of mechanical alignment and component positioning in total knee arthroplasty
    Ming Han Lincoln Liow
    Graham Seow-Hng Goh
    Hee-Nee Pang
    Darren Keng Jin Tay
    Ngai Nung Lo
    Seng Jin Yeo
    [J]. Archives of Orthopaedic and Trauma Surgery, 2016, 136 : 1173 - 1180
  • [6] Computer-assisted stereotaxic navigation improves the accuracy of mechanical alignment and component positioning in total knee arthroplasty
    Liow, Ming Han Lincoln
    Goh, Graham Seow-Hng
    Pang, Hee-Nee
    Tay, Darren Keng Jin
    Lo, Ngai Nung
    Yeo, Seng Jin
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (08) : 1173 - 1180
  • [7] Alignment of Computer-Assisted Total Knee Arthroplasty in Patients With Altered Hip Center
    Mullaji, Arun B.
    Lingaraju, A. P.
    Shetty, Gautam M.
    [J]. JOURNAL OF ARTHROPLASTY, 2011, 26 (07): : 1072 - 1077
  • [8] Evaluating Alternative Registration Planes in Imageless, Computer-Assisted Navigation Systems for Direct Anterior Total Hip Arthroplasty
    Farey, John E.
    Chai, Yuan
    Xu, Joshua
    Maes, Vincent
    Sadeghpour, Ameneh
    Baker, Neri A.
    Vigdorchik, Jonathan M.
    Walter, William L.
    [J]. Sensors, 2024, 24 (21)
  • [9] ACETABULAR CUP ALIGNMENT IN TOTAL HIP RECONSTRUCTION
    EVARTS, CM
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1974, (103) : 22 - 23
  • [10] Reliability and Correlation of the Force-PRO Device and Computer-Assisted Navigation System for Measurement of Acetabular Cup Position in Total Hip Arthroplasty
    Vijittrakarnrung, Chaiyanun
    Manupibul, Udomporn
    Charoensuk, Warakorn
    Wongsak, Siwadol
    Sa-Ngasoongsong, Paphon
    [J]. SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2020, 36