Direct Anatomic Registration in Computer-Assisted Total Hip Arthroplasty Improves Accuracy of Acetabular Cup Alignment

被引:2
|
作者
Patamarat, Apisit [1 ]
Laoruengthana, Artit [2 ,6 ]
Kitcharanant, Nitchanant [3 ]
Khantasit, Jakkaphong [4 ]
Thremthakanpon, Witoon [5 ]
机构
[1] Phra Nakhon Si Ayutthaya Hosp, Dept Orthopaed Surg, Ayutthaya, Thailand
[2] Naresuan Univ, Fac Med, Dept Orthopaed, Phitsanulok, Thailand
[3] Chiang Mai Univ, Fac Med, Dept Orthopaed, Chiang Mai, Thailand
[4] Phra Nakhon Si Ayutthaya Hosp, Dept Nursing, Ayutthaya, Thailand
[5] Phitsanulok Hosp, Dept Orthopaed, Phitsanulok, Thailand
[6] Naresuan Univ, Fac Med, Dept Orthopaed, 99 Moo Thapho, Phitsanulok 65000, Thailand
来源
ARTHROPLASTY TODAY | 2023年 / 21卷
关键词
Anatomical registration; Computer-assisted; Acetabular cup alignment; Total hip arthroplasty; ANTERIOR PELVIC PLANE; POLYETHYLENE WEAR; NAVIGATION; REPLACEMENT; ORIENTATION; POSITION; TILT;
D O I
10.1016/j.artd.2023.101148
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Computer-assisted total hip arthroplasty using direct anatomic registration (DAR) with acetabular center axis software is an alternative method to the indirect anterior pelvic plane method. The software maps the center of hip rotation and orientation of the native acetabulum in 3 dimensions. This study aimed to evaluate the accuracy of acetabular cup alignment using DAR navigation combined with a mechanical guide device (MGD).Methods: This prospective nonrandomized controlled study included 106 patients who underwent primary cementless total hip arthroplasty through the posterolateral approach. Fifty-four patients in the study group underwent DAR combined with MGD, whereas 52 patients underwent MGD only for acetabular cup positioning. Plain radiographs of both hips and computerized tomographic scans were obtained 2 months postoperatively for the evaluation of acetabular cup inclination and anteversion, respectively.Results: The acetabular cup alignment in the study group was within the Lewinnek safe zone more than that in the control group (81.5% vs 59.6%, P < .05). The study group had a mean inclination angle of 43.88(degrees degrees) (standard deviation [SD] 5.38) and anteversion angle of 12.82(degrees)(SD 5.99), whereas the control group had 41.10(degrees)(SD 6.79) and 12.82(degrees) (SD 9.53), respectively. There were no significant differences in estimated blood loss, length of stay, and Harris hip scores at preoperative and 3 and 6 months postoperatively, except for the operative time, which was longer in the study group (P < .01). There was 1 posterior hip dislocation in each group.Conclusions: DAR navigation combined with MGD provides better accuracy for acetabular cup positioning within the Lewinnek safe zone compared with the conventional technique.(c) 2023 The Authors. Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Prosthetic alignment and sizing in computer-assisted total knee arthroplasty
    Matsumoto, T
    Tsumura, N
    Kurosaka, M
    Muratsu, H
    Kuroda, R
    Ishimoto, K
    Tsujimoto, K
    Shiba, R
    Yoshiya, S
    [J]. INTERNATIONAL ORTHOPAEDICS, 2004, 28 (05) : 282 - 285
  • [22] Accuracy of a computer-assisted navigation system in resurfacing hip arthroplasty
    Pitto, R. P.
    Malak, S.
    Anderson, I. A.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2009, 33 (02) : 391 - 395
  • [23] Accuracy of a computer-assisted navigation system in resurfacing hip arthroplasty
    R. P. Pitto
    S. Malak
    I. A. Anderson
    [J]. International Orthopaedics, 2009, 33
  • [24] Acetabular cup size trends in total hip arthroplasty
    Mckenna, Daniel Patrick
    Price, Alex
    Mcaleese, Timothy
    Dahly, Darren
    Mckenna, Paul
    Cleary, May
    [J]. WORLD JOURNAL OF ORTHOPEDICS, 2024, 15 (01): : 39 - 44
  • [25] Should the acetabular cup be medialised in total hip arthroplasty?
    Bonnin, Michel P.
    Archbold, Pooler H. A.
    Basiglini, Luca
    Selmi, Tarik A.
    Beverland, David E.
    [J]. HIP INTERNATIONAL, 2011, 21 (04) : 428 - 435
  • [26] ACETABULAR CUP WEAR IN TOTAL HIP-ARTHROPLASTY
    RIMNAC, CM
    WILSON, PD
    FUCHS, MD
    WRIGHT, TM
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 1988, 19 (03) : 631 - 636
  • [27] Cementless total hip arthroplasty with a threaded acetabular cup
    J. Fernández-González
    R. Canosa Sevillano
    C. García-Araujo
    [J]. International Orthopaedics, 1997, 21 : 327 - 331
  • [28] Cementless total hip arthroplasty with a threaded acetabular cup
    Fernandez-Gonzalez, J
    Sevillano, RC
    Garcia-Araujo, C
    [J]. INTERNATIONAL ORTHOPAEDICS, 1997, 21 (05) : 327 - 331
  • [29] Clinical Validation of Computer-Assisted Navigation in Total Hip Arthroplasty
    Beaumont, Eric
    Beaumont, Pierre
    Odermat, Daniel
    Fontaine, Isabelle
    Jansen, Herbert
    Prince, Francois
    [J]. ADVANCES IN ORTHOPEDICS, 2011, 2011
  • [30] Limitations of Imageless Computer-Assisted Navigation for Total Hip Arthroplasty
    Lin, Fang
    Lim, Dohyung
    Wixson, Richard L.
    Milos, Steven
    Hendrix, Ronald W.
    Makhsous, Mohsen
    [J]. JOURNAL OF ARTHROPLASTY, 2011, 26 (04): : 596 - 605