Precise Acetabular Prosthesis Positioning Using a Novel Robot-Assisted Total Hip Arthroplasty System: A Multicenter, Randomized Controlled Trial

被引:0
|
作者
Geng, Xiao [1 ,2 ]
Dong, Ziyang [1 ,2 ]
Li, Yang [1 ,2 ]
Zhao, Minwei [1 ,2 ]
Liu, Yanqing [1 ,2 ]
Li, Zijian [1 ,2 ]
Cai, Hong [1 ,2 ]
Zhang, Ming [3 ]
Yan, Xinfeng [3 ]
Sun, Zhiwen [4 ]
Lv, Xin [4 ]
Guo, Feng [4 ]
Li, Feng [1 ,2 ]
Tian, Hua [1 ,2 ]
机构
[1] Peking Univ Third Hosp, Dept Orthopaed, Beijing, Peoples R China
[2] Engn Res Ctr Bone & Joint Precis Med, Beijing, Peoples R China
[3] Shandong First Med Univ, Affiliated Hosp 1, Shandong Prov Qianfoshan Hosp, Dept Orthopaed, Jinan, Peoples R China
[4] Chifeng Municipal Hosp, Dept Orthopaed, Chifeng, Peoples R China
关键词
acetabular prosthesis positioning; anteversion angle; inclination angle; robotic surgery; total hip arthroplasty; DISLOCATION; ARTHRITIS;
D O I
10.1111/os.14277
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective Total hip arthroplasty (THA) is currently one of the most effective treatment methods for end-stage hip joint disease, and its long-term effectiveness largely depends on the accurate placement of the acetabular prosthesis. In conventional surgery, the placement of the acetabular prosthesis mainly relies on the surgeon's clinical experience and surgical techniques. To further improve the accuracy of prosthesis placement, a new robotic system for THA is designed. The purpose of this study is to verify the effectiveness and safety of THA assisted by this robotic system. Method A multicenter, prospective, randomized controlled, superiority study design was adopted with statistical methods of t test and Chi-squared test. Participants undergoing primary THA have been enrolled in three centers of joint surgery in China since July 17, 2023. Robotic THA was operated in the experimental group, and conventional instruments were used in the control group. The primary outcome is the proportion of anteversion and inclination angles in the safe zone. The secondary outcomes include operation time, WOMAC score, Harris score, SF-36 health questionnaire, dislocation rate of hip joint, and rates of adverse events and serious adverse events. Results A total of 138 patients were included in this study. The proportion of both anteversion and inclination angles in the safe zone was 92.2% in the experimental group and 50.8% in the control group, with significant difference (p < 0.01). The average operation time in the experimental group and control group was 116.4 and 80.5 min respectively, with significant difference (p < 0.01). There was no significant difference in WOMAC score, Harris score, and SF-36 between the two groups (6 +/- 2) weeks after operation (p > 0.05). The dislocation rate of hip joint in the experimental group and control group were 3.0% and 1.5%, respectively, without significant difference (p > 0.05). The rate of adverse events and severe adverse events in the experimental group and control group also showed no significant difference (p > 0.05). No adverse events or serious adverse events were judged to be "definitely related" to the experimental instruments. Conclusion Robotic THA could prolong the operation time within an acceptable range, but more precise acetabular prosthesis positioning could be obtained when compared with conventional surgery. Besides, no significant difference was found in function scores, dislocation rate or other adverse events, which indicates that this new robot system shows both good effectiveness and safety in THA.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Accuracy of Acetabular Component Positioning Using Computer-assisted Navigation in Direct Anterior Total Hip Arthroplasty
    Bradley, Michael P.
    Benson, Jessica R.
    Muir, Jeffrey M.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (04)
  • [32] Robot-Assisted Total Hip Arthroplasty is Associated With an Increased Risk of Periprosthetic Fracture
    Singh, Aaron
    Kotzur, Travis
    Peng, Lindsey
    Emukah, Chimobi
    Buttacavoli, Frank
    Moore, Chance
    JOURNAL OF ARTHROPLASTY, 2024, 39 (09): : S353 - S358
  • [33] Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty - A prospective, randomized, controlled study
    Parratte, Sebastien
    Argenson, Jean-Noel A.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (03): : 494 - 499
  • [34] Cup positioning relative to the acetabular rim planned with three-dimensional computed tomography improves precision in total hip arthroplasty: a randomized controlled trial
    Pongkunakorn, Anuwat
    Wongkamthong, Napon
    Ruktrakul, Rukthanin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2025, 20 (01):
  • [35] A Systematic Study to Compare the Precise Implantation of Hololens 2 Assisted with Acetabular Prosthesis for Total Hip Replacement
    Rong, Ke
    Wu, Xuhua
    Xia, Qingquan
    Chen, Jie
    Fei, Teng
    Li, Xujun
    Jiang, Weimin
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2022, 12 (12) : 2461 - 2466
  • [36] Personalized image-based templates for precise acetabular prosthesis placement in total hip arthroplasty:a pilot study
    Bin CHENShengxiang XIAOPengcheng GUXiangjin LINDepartment of Orthopaedicsthe First Affiliated HospitalSchool of MedicineZhejiang UniversityHangzhou China
    Journal of Zhejiang University-Science B(Biomedicine & Biotechnology), 2010, 11 (09) : 673 - 680
  • [37] Personalized image-based templates for precise acetabular prosthesis placement in total hip arthroplasty: a pilot study
    Bin Chen
    Sheng-xiang Xiao
    Peng-cheng Gu
    Xiang-jin Lin
    Journal of Zhejiang University SCIENCE B, 2010, 11 : 673 - 680
  • [38] Personalized image-based templates for precise acetabular prosthesis placement in total hip arthroplasty: a pilot study
    Chen, Bin
    Xiao, Sheng-xiang
    Gu, Peng-cheng
    Lin, Xiang-jin
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE B, 2010, 11 (09): : 673 - 680
  • [39] A Multicenter Randomized Controlled Trial Evaluating the Effectiveness of Cognitive Training for Anterior Approach Total Hip Arthroplasty
    Logishetty, Kartik
    Gofton, Wade T.
    Rudran, Branavan
    Beaule, Paul E.
    Gupte, Chinmay M.
    Cobb, Justin P.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2020, 102 (02): : E7
  • [40] Inclinometer use in primary total hip arthroplasty does not improve acetabular component positioning: a non-randomized control trial
    Goldstein, Kyle
    Tyndall, Wyatt
    Nickol, Michaela E.
    van der Merwe, Johannes M.
    ARTHROPLASTY, 2024, 6 (01)