Precise Acetabular Prosthesis Positioning Using a Novel Robot-Assisted Total Hip Arthroplasty System: A Multicenter, Randomized Controlled Trial

被引:0
|
作者
Geng, Xiao [1 ,2 ]
Dong, Ziyang [1 ,2 ]
Li, Yang [1 ,2 ]
Zhao, Minwei [1 ,2 ]
Liu, Yanqing [1 ,2 ]
Li, Zijian [1 ,2 ]
Cai, Hong [1 ,2 ]
Zhang, Ming [3 ]
Yan, Xinfeng [3 ]
Sun, Zhiwen [4 ]
Lv, Xin [4 ]
Guo, Feng [4 ]
Li, Feng [1 ,2 ]
Tian, Hua [1 ,2 ]
机构
[1] Peking Univ Third Hosp, Dept Orthopaed, Beijing, Peoples R China
[2] Engn Res Ctr Bone & Joint Precis Med, Beijing, Peoples R China
[3] Shandong First Med Univ, Affiliated Hosp 1, Shandong Prov Qianfoshan Hosp, Dept Orthopaed, Jinan, Peoples R China
[4] Chifeng Municipal Hosp, Dept Orthopaed, Chifeng, Peoples R China
关键词
acetabular prosthesis positioning; anteversion angle; inclination angle; robotic surgery; total hip arthroplasty; DISLOCATION; ARTHRITIS;
D O I
10.1111/os.14277
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective Total hip arthroplasty (THA) is currently one of the most effective treatment methods for end-stage hip joint disease, and its long-term effectiveness largely depends on the accurate placement of the acetabular prosthesis. In conventional surgery, the placement of the acetabular prosthesis mainly relies on the surgeon's clinical experience and surgical techniques. To further improve the accuracy of prosthesis placement, a new robotic system for THA is designed. The purpose of this study is to verify the effectiveness and safety of THA assisted by this robotic system. Method A multicenter, prospective, randomized controlled, superiority study design was adopted with statistical methods of t test and Chi-squared test. Participants undergoing primary THA have been enrolled in three centers of joint surgery in China since July 17, 2023. Robotic THA was operated in the experimental group, and conventional instruments were used in the control group. The primary outcome is the proportion of anteversion and inclination angles in the safe zone. The secondary outcomes include operation time, WOMAC score, Harris score, SF-36 health questionnaire, dislocation rate of hip joint, and rates of adverse events and serious adverse events. Results A total of 138 patients were included in this study. The proportion of both anteversion and inclination angles in the safe zone was 92.2% in the experimental group and 50.8% in the control group, with significant difference (p < 0.01). The average operation time in the experimental group and control group was 116.4 and 80.5 min respectively, with significant difference (p < 0.01). There was no significant difference in WOMAC score, Harris score, and SF-36 between the two groups (6 +/- 2) weeks after operation (p > 0.05). The dislocation rate of hip joint in the experimental group and control group were 3.0% and 1.5%, respectively, without significant difference (p > 0.05). The rate of adverse events and severe adverse events in the experimental group and control group also showed no significant difference (p > 0.05). No adverse events or serious adverse events were judged to be "definitely related" to the experimental instruments. Conclusion Robotic THA could prolong the operation time within an acceptable range, but more precise acetabular prosthesis positioning could be obtained when compared with conventional surgery. Besides, no significant difference was found in function scores, dislocation rate or other adverse events, which indicates that this new robot system shows both good effectiveness and safety in THA.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Development of a novel robot-assisted orthopaedic system designed for total knee arthroplasty
    Sugita, N
    Warisawa, S
    Mitsuishi, M
    Suzuki, M
    Moriya, H
    Kuramoto, K
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2004, PT 2, PROCEEDINGS, 2004, 3217 : 153 - 160
  • [22] Electromagnetic navigation system for acetabular component placement in total hip arthroplasty is more precise and accurate than the freehand technique: a randomized, controlled trial with 84 patients
    Mihalic, Rene
    Zdovc, Jurij
    Mohar, Janez
    Trebse, Rihard
    ACTA ORTHOPAEDICA, 2020, 91 (06) : 675 - 681
  • [23] Impact of surgeon handedness in manual and robot-assisted total hip arthroplasty
    Kong, Xiangpeng
    Yang, Minzhi
    Li, Xiang
    Ni, Ming
    Zhang, Guoqiang
    Chen, Jiying
    Chai, Wei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [24] Robot-assisted total hip arthroplasty: Clinical outcomes and complication rate
    Perets, Itay
    Walsh, John P.
    Close, Mary R.
    Mu, Brian H.
    Yuen, Leslie C.
    Domb, Benjamin G.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2018, 14 (04):
  • [25] Impact of surgeon handedness in manual and robot-assisted total hip arthroplasty
    Xiangpeng Kong
    Minzhi Yang
    Xiang Li
    Ming Ni
    Guoqiang Zhang
    Jiying Chen
    Wei Chai
    Journal of Orthopaedic Surgery and Research, 15
  • [26] Is the Acetabular Cup Orientation Different in Robot-Assisted and Conventional Total Hip Arthroplasty With Right-Handed Surgeons Using an Anterolateral Approach?
    Kara, Gokhan Kursat
    Turan, Kayhan
    Eroglu, Osman Nuri
    Ozturk, Cagatay
    Ertuerer, Erden
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (07)
  • [28] Suitability of the MP1000 system for robot-assisted partial nephrectomy: a multicenter randomized controlled noninferiority trial
    Gao, Yu
    Yang, Yang
    Niu, Shaoxi
    He, Wang
    Tao, Jin
    Guo, Shengjie
    Li, Hongzhao
    Ma, Xin
    Ai, Xing
    Huang, Jian
    Zhou, Fangjian
    Zhang, Xuepei
    Zhang, Xu
    INTERNATIONAL JOURNAL OF SURGERY, 2024, 110 (05) : 2803 - 2809
  • [29] Robot-assisted radical nephroureterectomy using the KangDuo Surgical Robot-01 System versus the da Vinci System: a multicenter prospective randomized controlled trial
    Zhang, Zhongyuan
    Li, Zhenyu
    Xu, Weifeng
    Wang, Xuan
    Zhu, Shengcai
    Dong, Jie
    Tian, Xiaojun
    Zuo, Wei
    Tang, Qi
    Li, Zhihua
    Yang, Kunlin
    Xue, Xiaoqiang
    Li, Yingjie
    Zhang, Hongxian
    Zhang, Qiming
    Chen, Silu
    Jin, Zhaoheng
    Li, Xuesong
    Ji, Zhigang
    Ma, Lulin
    Liu, Ming
    INTERNATIONAL BRAZ J UROL, 2024, 50 (06): : 727 - 736
  • [30] Robot-assisted Minimally Invasive Total Knee Arthroplasty System
    Zhang Y.
    Li W.
    Chen J.
    Song G.
    Qi Y.
    Xu Y.
    Wang J.
    Jiqiren/Robot, 2021, 43 (04): : 386 - 394