Potential of Near-Infrared Optical Techniques for Non-invasive Blood Glucose Measurement: A Pilot Study

被引:0
|
作者
Fathimal, M. Sameera [1 ]
Kumar, Janardanan Subramonia [2 ]
Prabha, A. Jeya [1 ]
Selvaraj, Jothiraj [1 ]
Shilparani, F. Fabiola Jemmie [1 ]
Kirubha, S. P. Angeline [1 ]
机构
[1] SRM Inst Sci & Technol, Coll Engn & Technol, Dept Biomed Engn, Kattankulathur 603203, Tamil Nadu, India
[2] SRM Inst Sci & Technol, SRM Med Coll Hosp & Res Ctr, Dept Gen Med, Kattankulathur 603203, Tamil Nadu, India
关键词
Diabetes mellitus; Glucose monitoring; Non-invasive method; Near-infrared wavelength; Optical device; TISSUE; SPECTROSCOPY;
D O I
10.1016/j.irbm.2024.100870
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Diabetes mellitus manifested by escalated blood glucose, demands periodic or continuous glucose monitoring in the pursuit of improved control, optimal management, and appropriate medication. The existing state-of-the-art for blood glucose estimation are invasive methodologies necessitating the acquisition of blood sample through either a finger-stick or venipuncture. Methods: We propose a dual Near-infrared wavelength integrated in a 3D printed enclosure as the optical prototype for non-invasive glucose estimation. We acquired data from both diabetic and healthy subjects with the developed system and subsequently validated the system. Results: The system demonstrated commendable clinical accuracy, as evidenced by the alignment of data pairs representing actual blood glucose levels and blood glucose levels predicted by our optical system within the A+B zones of the Parkes error grid and zones of no-risk and lower risk as defined by the surveillance error grid. We achieved compliant pairs percentage of 95.6%, which satisfies the accuracy requirements of the blood glucose monitoring surveillance study. The mean absolute percentage error attained with the proposed device (5.99%) was significant in predicting the blood glucose. Conclusion: We successfully deployed the NIR wavelengths functionality as the promising approach for glucose monitoring, offering new possibilities for improved medical interventions. (c) 2024 AGBM. Published by Elsevier Masson SAS. All rights are reserved, including those for text and
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Non-invasive Blood Glucose Measurement Based on ATR Infrared Spectroscopy
    Ishizawa, Hiroaki
    Muro, Akinobu
    Takano, Tomohiro
    Honda, Kazuya
    Kanai, Hiroyuki
    2008 PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-7, 2008, : 292 - 295
  • [42] Research on the background correction in the non-invasive sensing of glucose by near-infrared spectroscopy
    Liu Rong
    Gu Xiao-yu
    Xu Ke-xin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (08) : 1772 - 1775
  • [43] Application of genetic algorithms in fundamental study of non-invasive measurement of human blood glucose concentration with near infrared spectroscopy
    Wang, H
    Li, QB
    Liu, ZY
    Xu, KX
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (07) : 779 - 783
  • [44] Analysis of sensitivity and optical path-length in non-invasive measurement of glucose with near infrared spectroscopy
    Luo, YH
    Liu, R
    Chen, WL
    Cui, HX
    Xu, KX
    COMPLEX DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS II, 2005, 5696 : 205 - 214
  • [45] Research on non-invasive intracranial pressure measurement using near-infrared light
    Lin, L
    Li, G
    Xiang, SX
    Sun, JF
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT, 2002, 4916 : 450 - 456
  • [46] Net analyte signal with floating reference theory in non-invasive blood glucose sensing by near-infrared spectroscopy
    Zhang, Wanjie
    Liu, Rong
    Zhang, Wen
    Zheng, Jiaxiang
    Xu, Kexin
    CHINESE OPTICS LETTERS, 2012, 10 (08)
  • [47] Net analyte signal with floating reference theory in non-invasive blood glucose sensing by near-infrared spectroscopy
    张婉洁
    刘蓉
    张雯
    郑加祥
    徐可欣
    ChineseOpticsLetters, 2012, 10 (08) : 74 - 77
  • [48] Performance of a Non-Invasive System for Monitoring Blood Glucose Levels Based on Near-Infrared Spectroscopy Technology (Glucube®)
    Gomez-Peralta, Fernando
    Romero, Luis Gabriel Luque
    Puppo-Moreno, Antonio
    Riesgo, Jesus
    SENSORS, 2024, 24 (23)
  • [49] NIV-NGM - A Novel Non-invasive Blood Glucose Monitoring Method based on Near-infrared Videos
    Liu, Weijie
    Wang, Guangyu
    Huang, Anpeng
    Wang, Ping
    2019 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICINE (BIBM), 2019, : 953 - 957
  • [50] A Non-Invasive Blood Insulin and Glucose Monitoring System based on Near-Infrared Spectroscopy with Remote Data Logging
    Nandi, Bodhayan
    Mondal, Prosenjit
    Chowdhury, Shubhajit Roy
    2018 31ST IEEE INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS 2018), 2018, : 274 - 279