Net analyte signal with floating reference theory in non-invasive blood glucose sensing by near-infrared spectroscopy

被引:5
|
作者
Zhang, Wanjie [1 ]
Liu, Rong [1 ]
Zhang, Wen [1 ]
Zheng, Jiaxiang [1 ]
Xu, Kexin [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
MULTIVARIATE CALIBRATION; SPECTRA; MODELS;
D O I
10.3788/COL201210.083002
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Based on the floating reference theory, a new method for extracting the net analyte signal (NAS) is proposed. The noise background subspace is spanned by spectra at the floating radial reference point, and then, the spectra at the measurement point are projected on the subspace. Thereafter, the glucose concentrations in intralipid solutions are investigated through Monte Carlo simulation and experiments, and the partial least squares (PLS) models with and without NAS analysis are built. The root mean square errors of calibration and prediction reach to 28.87% and 27.33%, respectively. The results confirm the existence of information induced by glucose concentration variations as well as the validity of the floating reference theory.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Net analyte signal with floating reference theory in non-invasive blood glucose sensing by near-infrared spectroscopy
    张婉洁
    刘蓉
    张雯
    郑加祥
    徐可欣
    ChineseOpticsLetters, 2012, 10 (08) : 74 - 77
  • [2] Extraction of Effective Signal in Non-Invasive Blood Glucose Sensing with Near-Infrared Spectroscopy
    Han Guang
    Liu Rong
    Xu Ke-xin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38 (05) : 1599 - 1604
  • [3] The feasibility investigation of non-invasive blood glucose sensing based on near-infrared spectroscopy
    Gu, Xiaoyu
    Deng, Bin
    An, Lin
    Chen, Wenliang
    Xu, Kexin
    OPTICAL DIAGNOSTICS AND SENSING VI, 2006, 6094
  • [4] Non-invasive blood glucose sensing on human body with near-infrared reflection spectroscopy
    Huang Zhen-hao
    Hao Chang-ning
    Zhang Lin-lin
    Huang Yan-chao
    Shi Yi-qin
    Jiang Geng-ru
    Duan Jun-li
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: ADVANCES IN INFRARED IMAGING AND APPLICATIONS, 2011, 8193
  • [5] Research on the background correction in the non-invasive sensing of glucose by near-infrared spectroscopy
    Liu Rong
    Gu Xiao-yu
    Xu Ke-xin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (08) : 1772 - 1775
  • [6] Non-invasive Blood Glucose Measurement Scheme Based on Near-infrared Spectroscopy
    Wang Shulei
    Yuan Xueguang
    Zhang Yangan
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2017,
  • [7] Determination of the reference position in the near-infrared non-invasive blood glucose measurement in vivo
    Han, Guang
    Liu, Jin
    Liu, Rong
    Xu, Kexin
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VII, 2017, 0024
  • [8] Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy
    Yadav, Jyoti
    Rani, Asha
    Singh, Vijander
    Murari, Bhaskar Mohan
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2015, 18 : 214 - 227
  • [9] Non-invasive Self Monitoring of Blood Glucose System Using Near-infrared Spectroscopy
    Yoshinari, Hiroki
    Ishizawa, Hiroaki
    Fukuda, Masaya
    Tokutake, Shota
    Koyama, Shouhei
    Miyauchi, Yuki
    2012 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), 2012, : 1852 - 1854
  • [10] Non-invasive Blood Glucose Estimation using Near-Infrared Spectroscopy based on SVR
    Zhang, Yue
    Wang, Ziliang
    2017 IEEE 3RD INFORMATION TECHNOLOGY AND MECHATRONICS ENGINEERING CONFERENCE (ITOEC), 2017, : 594 - 598