Net analyte signal with floating reference theory in non-invasive blood glucose sensing by near-infrared spectroscopy

被引:5
|
作者
Zhang, Wanjie [1 ]
Liu, Rong [1 ]
Zhang, Wen [1 ]
Zheng, Jiaxiang [1 ]
Xu, Kexin [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
MULTIVARIATE CALIBRATION; SPECTRA; MODELS;
D O I
10.3788/COL201210.083002
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Based on the floating reference theory, a new method for extracting the net analyte signal (NAS) is proposed. The noise background subspace is spanned by spectra at the floating radial reference point, and then, the spectra at the measurement point are projected on the subspace. Thereafter, the glucose concentrations in intralipid solutions are investigated through Monte Carlo simulation and experiments, and the partial least squares (PLS) models with and without NAS analysis are built. The root mean square errors of calibration and prediction reach to 28.87% and 27.33%, respectively. The results confirm the existence of information induced by glucose concentration variations as well as the validity of the floating reference theory.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Non-invasive glucose sensing with near-infrared spectroscopy enhanced by optical measurement conditions reproduction technique
    Xu, KX
    Qiu, QJ
    Jiang, JY
    Yang, XY
    OPTICS AND LASERS IN ENGINEERING, 2005, 43 (10) : 1096 - 1106
  • [22] Extraction of glucose information in blood glucose measurement by non-invasive near-infrared spectra
    Liu, R
    Chen, WL
    Gu, XY
    Luo, YH
    Xu, KX
    OPTICAL DIAGNOSTICS AND SENSING V, 2005, 5702 : 30 - 38
  • [23] Chance correlation in non-invasive glucose measurement using near-infrared spectroscopy
    Liu, R
    Chen, WL
    Gu, XY
    Wang, RKK
    Xu, KX
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2005, 38 (15) : 2675 - 2681
  • [24] A preliminary verification of the floating reference measurement method for non-invasive blood glucose sensing
    Min, Xiaolin
    Liu, Rong
    Fu, Bo
    Xu, Kexin
    OPTICS AND LASER TECHNOLOGY, 2017, 91 : 7 - 12
  • [25] An Impedance and Multi-Wavelength Near-Infrared Spectroscopy IC for Non-Invasive Blood Glucose Estimation
    Song, Kiseok
    Ha, Unsoo
    Park, Seongwook
    Bae, Joonsung
    Yoo, Hoi-Jun
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2015, 50 (04) : 1025 - 1037
  • [26] Functional near-infrared spectroscopy in non-invasive neuromodulation
    Congcong Huo
    Gongcheng Xu
    Hui Xie
    Tiandi Chen
    Guangjian Shao
    Jue Wang
    Wenhao Li
    Daifa Wang
    Zengyong Li
    Neural Regeneration Research, 2024, 19 (07) : 1517 - 1522
  • [27] Research of transmissive near infrared spectroscopy for non-invasive blood glucose measurement
    Yang, Wenming
    Liao, Ningfang
    Li, Yasheng
    Shao, Liwei
    Huang, Dehuang
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VII, 2017, 0024
  • [28] Near-Infrared Spectroscopy (NIRS) for Non-Invasive Diagnosis
    Baig, Saeeda
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2023, 33 (11): : 1215 - 1216
  • [29] Functional near-infrared spectroscopy in non-invasive neuromodulation
    Huo, Congcong
    Xu, Gongcheng
    Xie, Hui
    Chen, Tiandi
    Shao, Guangjian
    Wang, Jue
    Li, Wenhao
    Wang, Daifa
    Li, Zengyong
    NEURAL REGENERATION RESEARCH, 2024, 19 (07) : 1517 - 1522
  • [30] Preliminary study of mechanism of non-invasive blood glucose measurement based on near-infrared diffuse reflectance spectroscopy
    Chen, WL
    Liu, R
    Luo, YH
    Han, YH
    Xu, KX
    Complex Dynamics and Fluctuations in Biomedical Photonics II, 2005, 5696 : 91 - 100