Net analyte signal with floating reference theory in non-invasive blood glucose sensing by near-infrared spectroscopy

被引:5
|
作者
Zhang, Wanjie [1 ]
Liu, Rong [1 ]
Zhang, Wen [1 ]
Zheng, Jiaxiang [1 ]
Xu, Kexin [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
MULTIVARIATE CALIBRATION; SPECTRA; MODELS;
D O I
10.3788/COL201210.083002
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Based on the floating reference theory, a new method for extracting the net analyte signal (NAS) is proposed. The noise background subspace is spanned by spectra at the floating radial reference point, and then, the spectra at the measurement point are projected on the subspace. Thereafter, the glucose concentrations in intralipid solutions are investigated through Monte Carlo simulation and experiments, and the partial least squares (PLS) models with and without NAS analysis are built. The root mean square errors of calibration and prediction reach to 28.87% and 27.33%, respectively. The results confirm the existence of information induced by glucose concentration variations as well as the validity of the floating reference theory.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] A Non-Invasive Blood Insulin and Glucose Monitoring System based on Near-Infrared Spectroscopy with Remote Data Logging
    Nandi, Bodhayan
    Mondal, Prosenjit
    Chowdhury, Shubhajit Roy
    2018 31ST IEEE INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS 2018), 2018, : 274 - 279
  • [32] Performance of a Non-Invasive System for Monitoring Blood Glucose Levels Based on Near-Infrared Spectroscopy Technology (Glucube®)
    Gomez-Peralta, Fernando
    Romero, Luis Gabriel Luque
    Puppo-Moreno, Antonio
    Riesgo, Jesus
    SENSORS, 2024, 24 (23)
  • [33] Net Analyte Signal Calculation in Near-Infrared Spectra Calibration
    Liu, Weiling
    Liu, Libing
    Yu, Qilian
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 205 - +
  • [34] Calibration break-through for near-infrared, non-invasive blood glucose monitoring
    Garg, SK
    Fischer, JS
    Ruchti, TL
    Blank, TB
    Lorenz, AD
    Monfre, SL
    DIABETES, 2002, 51 : A122 - A122
  • [35] Enhancing calibration models for non-invasive near-infrared spectroscopical blood glucose determination
    Fischbacher, C
    Jagemann, KU
    Danzer, K
    Muller, UA
    Papenkordt, L
    Schuler, J
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (01): : 78 - 82
  • [36] Enhancing calibration models for non-invasive near-infrared spectroscopical blood glucose determination
    C. Fischbacher
    K.-U. Jagemann
    K. Danzer
    U. A. Müller
    L. Papenkordt
    J. Schüler
    Fresenius' Journal of Analytical Chemistry, 1997, 359 : 78 - 82
  • [37] Non-invasive measurement of intraocular pressure by near-infrared spectroscopy
    Weissbrodt, D
    Müeller, R
    Backhaus, J
    Jonas, JB
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (02) : 307 - 308
  • [38] Non-invasive confirmation of the identity of tablets by near-infrared spectroscopy
    Ulmschneider, M
    Pénigault, E
    ANALUSIS, 2000, 28 (04) : 336 - 346
  • [39] Extraction of net analyte signal in the noninvasive blood glucose sensing
    Liu, Rong
    Chen, Wen-Liang
    Gu, Xiao-Yu
    Xu, Ke-Xin
    Nami Jishu yu Jingmi Gongcheng/Nanotechnology and Precision Engineering, 2008, 6 (03): : 207 - 211
  • [40] Development of non-invasive blood glucose regression based on near-infrared spectroscopy combined with a deep-learning method
    Wang, Zhuyu
    Zhou, Linhua
    Liu, Tianqing
    Huan, Kewei
    Jia, Xiaoning
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2022, 55 (21)