Potential of Near-Infrared Optical Techniques for Non-invasive Blood Glucose Measurement: A Pilot Study

被引:0
|
作者
Fathimal, M. Sameera [1 ]
Kumar, Janardanan Subramonia [2 ]
Prabha, A. Jeya [1 ]
Selvaraj, Jothiraj [1 ]
Shilparani, F. Fabiola Jemmie [1 ]
Kirubha, S. P. Angeline [1 ]
机构
[1] SRM Inst Sci & Technol, Coll Engn & Technol, Dept Biomed Engn, Kattankulathur 603203, Tamil Nadu, India
[2] SRM Inst Sci & Technol, SRM Med Coll Hosp & Res Ctr, Dept Gen Med, Kattankulathur 603203, Tamil Nadu, India
关键词
Diabetes mellitus; Glucose monitoring; Non-invasive method; Near-infrared wavelength; Optical device; TISSUE; SPECTROSCOPY;
D O I
10.1016/j.irbm.2024.100870
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Diabetes mellitus manifested by escalated blood glucose, demands periodic or continuous glucose monitoring in the pursuit of improved control, optimal management, and appropriate medication. The existing state-of-the-art for blood glucose estimation are invasive methodologies necessitating the acquisition of blood sample through either a finger-stick or venipuncture. Methods: We propose a dual Near-infrared wavelength integrated in a 3D printed enclosure as the optical prototype for non-invasive glucose estimation. We acquired data from both diabetic and healthy subjects with the developed system and subsequently validated the system. Results: The system demonstrated commendable clinical accuracy, as evidenced by the alignment of data pairs representing actual blood glucose levels and blood glucose levels predicted by our optical system within the A+B zones of the Parkes error grid and zones of no-risk and lower risk as defined by the surveillance error grid. We achieved compliant pairs percentage of 95.6%, which satisfies the accuracy requirements of the blood glucose monitoring surveillance study. The mean absolute percentage error attained with the proposed device (5.99%) was significant in predicting the blood glucose. Conclusion: We successfully deployed the NIR wavelengths functionality as the promising approach for glucose monitoring, offering new possibilities for improved medical interventions. (c) 2024 AGBM. Published by Elsevier Masson SAS. All rights are reserved, including those for text and
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy
    Yadav, Jyoti
    Rani, Asha
    Singh, Vijander
    Murari, Bhaskar Mohan
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2015, 18 : 214 - 227
  • [22] Non-invasive Self Monitoring of Blood Glucose System Using Near-infrared Spectroscopy
    Yoshinari, Hiroki
    Ishizawa, Hiroaki
    Fukuda, Masaya
    Tokutake, Shota
    Koyama, Shouhei
    Miyauchi, Yuki
    2012 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), 2012, : 1852 - 1854
  • [23] Enhancing calibration models for non-invasive near-infrared spectroscopical blood glucose determination
    C. Fischbacher
    K.-U. Jagemann
    K. Danzer
    U. A. Müller
    L. Papenkordt
    J. Schüler
    Fresenius' Journal of Analytical Chemistry, 1997, 359 : 78 - 82
  • [24] Non-invasive Blood Glucose Estimation using Near-Infrared Spectroscopy based on SVR
    Zhang, Yue
    Wang, Ziliang
    2017 IEEE 3RD INFORMATION TECHNOLOGY AND MECHATRONICS ENGINEERING CONFERENCE (ITOEC), 2017, : 594 - 598
  • [25] Non-invasive blood glucose sensing on human body with near-infrared reflection spectroscopy
    Huang Zhen-hao
    Hao Chang-ning
    Zhang Lin-lin
    Huang Yan-chao
    Shi Yi-qin
    Jiang Geng-ru
    Duan Jun-li
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: ADVANCES IN INFRARED IMAGING AND APPLICATIONS, 2011, 8193
  • [26] Study on optical measurement conditions for non-invasive blood glucose sensing
    Xu, KX
    Chen, WL
    Jiang, JY
    Qiu, QJ
    COMPLEX DYNAMICS, FLUCTUATIONS, CHAOS, AND FRACTALS IN BIOMEDICAL PHOTONICS, 2004, 5 (19): : 83 - 91
  • [27] Non-invasive measurement of intraocular pressure by near-infrared spectroscopy
    Weissbrodt, D
    Müeller, R
    Backhaus, J
    Jonas, JB
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (02) : 307 - 308
  • [28] PRETREATMENT METHOD RESEARCH OF NEAR-INFRARED SPECTRA IN BLOOD COMPONENT NON-INVASIVE MEASUREMENT
    Li, Li Na
    Zhang, Guang Jun
    Li, Qing Bo
    MODERN PHYSICS LETTERS B, 2009, 23 (07): : 925 - 937
  • [29] Application of radial basis function networks in fundamental study of non-invasive measurement of human blood glucose concentration with near-infrared spectroscopy
    Wang, H
    Liu, ZY
    Li, QB
    Xu, KX
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (04) : 440 - 443
  • [30] Verification of Signal Extraction Capability of Near-Infrared Non-Invasive Blood Glucose Detection System
    Kong Dan-dan
    Han Tong-shuai
    Ge Qing
    Chen Wen-liang
    Liu Rong
    Li Chen-xi
    Xu Ke-xin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40 (11) : 3438 - 3442