Multidimensional RF pulse design with consideration of concomitant field effects

被引:0
|
作者
Zhao, Ziwei [1 ]
Lee, Nam G. [2 ]
Nayak, Krishna S. [1 ,2 ]
机构
[1] Univ Southern Calif, Viterbi Sch Engn, Ming Hsieh Dept Elect & Comp Engn, 3740 McClintock Ave,EEB 400, Los Angeles, CA 90089 USA
[2] Univ Southern Calif, Viterbi Sch Engn, Alfred Mann Dept Biomed Engn, Los Angeles, CA USA
基金
美国国家科学基金会;
关键词
concomitant field effects; gradient impulse response function (GIRF); low-field; multi-dimensional RF pulse design; RATE SELECTIVE EXCITATION; QUANTITATIVE CHARACTERIZATION; MAGNETIC-RESONANCE; GRADIENT; MR; INHOMOGENEITY; OPTIMIZATION; ARTIFACTS; SAR;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a small-tip multidimensional RF pulse design procedure that incorporates linear time-invariant gradient imperfections and concomitant field effects. This could be particularly important for contemporary low-field MRI systems with high-performance gradients. Theory and Methods: We developed an extension of the small-tip excitation k-space formalism, where concomitant fields were approximated as a Bloch-Siegert shift in the rotating frame. This was evaluated using realistic simulations of 2D selective excitation at various field strengths (0.2T, 0.55T, 1.5T, 3T, and 7T) with single and parallel transmit. Simulated excitation profiles from the original and extended k-space formalisms were compared. Experimental validations were performed at 0.55T with a single-channel transmit. Results: The extended formalism provides improved 2D excitation profiles in all scenarios simulated, compared against the original formalism. The proposed method corrects the concomitant field effects on 2D selective excitations for B-0 > 0.2T when the magnitude of the B-0 is far larger than that of nonrotating concomitant fields. Simulation and phantom experiments at 0.55T match well for both original and proposed methods, with the proposed method providing sharper and more accurate excitation profiles at off-isocenter distances up to 15cm. The impact of the proposed method is greatest in scenarios where concomitant fields are substantial, such as low field strengths and off-isocenter. Conclusion: Concomitant fields can be modeled as a Bloch-Siegert shift in the rotating frame during multidimensional RF pulse design, resulting in improved excitation profiles with sharp edges. This is important to consider for off-isocenter excitations and imaging at low field strengths with strong gradients.
引用
收藏
页码:718 / 729
页数:12
相关论文
共 50 条
  • [1] Ultrafast (milliseconds), multidimensional RF pulse design with deep learning
    Vinding, Mads Sloth
    Skyum, Birk
    Sangill, Ryan
    Lund, Torben Ellegaard
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (02) : 586 - 599
  • [2] Nonuniform and multidimensional Shinnar-Le Roux RF pulse design method
    Grissom, William A.
    McKinnon, Graeme C.
    Vogel, Mika W.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (03) : 690 - 702
  • [3] Fast Large-Tip-Angle Multidimensional and Parallel RF Pulse Design in MRI
    Grissom, William A.
    Xu, Dan
    Kerr, Adam B.
    Fessler, Jeffrey A.
    Noll, Douglas C.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (10) : 1548 - 1559
  • [4] Iterative RF pulse design for multidimensional, small-tip-angle selective excitation
    Yip, CY
    Fessler, JA
    Douglas, CN
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (04) : 908 - 917
  • [5] HIGH FIELD RF SUPERCONDUCTIVITY: TO PULSE OR NOT TO PULSE?
    Campisi, Isidoro Enrico
    IEEE Transactions on Magnetics, 1984, MAG-21 (02)
  • [6] HIGH-FIELD RF SUPERCONDUCTIVITY - TO PULSE OR NOT TO PULSE
    CAMPISI, IE
    IEEE TRANSACTIONS ON MAGNETICS, 1985, 21 (02) : 134 - 141
  • [7] Design a logamp RF pulse detector
    Nash, E
    MICROWAVES & RF, 2000, 39 (01) : 62 - +
  • [8] On consideration of radiated power in RF field simulations for MRI
    Liu, Wanzhan
    Kao, Chien-ping
    Collins, Christopher M.
    Smith, Michael B.
    Yang, Qing X.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) : 290 - 294
  • [9] Parallel transmission RF pulse design for eddy current correction at ultra high field
    Zheng, Hai
    Zhao, Tiejun
    Qian, Yongxian
    Ibrahim, Tamer
    Boada, Fernando
    JOURNAL OF MAGNETIC RESONANCE, 2012, 221 : 139 - 146
  • [10] Slit design consideration on the ferromagnetic RF integrated inductor
    Yamaguchi, Masahiro
    Yamada, Keiju
    Kim, Ki Hyeon
    IEEE TRANSACTIONS ON MAGNETICS, 2006, 42 (10) : 3341 - 3343