Nonuniform and multidimensional Shinnar-Le Roux RF pulse design method

被引:13
|
作者
Grissom, William A. [1 ]
McKinnon, Graeme C. [2 ]
Vogel, Mika W. [1 ]
机构
[1] GE Global Res, Imaging Technol Lab, Munich, Germany
[2] GE Healthcare, Global Appl Sci Lab, Milwaukee, WI USA
关键词
SLR multidimensional excitation; RF pulse design; selective excitation; ANGLE SELECTIVE EXCITATION; RADIO-FREQUENCY PULSES; SPIN-ECHO; ALGORITHM; SEQUENCE;
D O I
10.1002/mrm.23269
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Shinnar-Le Roux (SLR) radiofrequency (RF) pulse design algorithm is widely used for designing slice-selective RF pulses due to its intuitiveness, optimality, and speed. SLR is limited, however, in that it is only capable of designing one-dimensional pulses played along constant gradients. We present a nonuniform SLR RF pulse design framework that extends most of the capabilities of classical SLR to nonuniform gradient trajectories and multiple dimensions. Specifically, like classical SLR, the new method is a hard pulse approximation-based technique that uses filter design relationships to produce the lowest power RF pulse that satisfies target magnetization ripple levels. The new method is validated and compared with methods conventionally used for nonuniform and multidimensional large-tip-angle RF pulse design. Magn Reson Med, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:690 / 702
页数:13
相关论文
共 22 条
  • [1] Design of Multidimensional Shinnar-Le Roux Radiofrequency Pulses
    Ma, Chao
    Liang, Zhi-Pei
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (02) : 633 - 645
  • [2] General parameter relations for the Shinnar-Le Roux pulse design algorithm
    Lee, Kuan J.
    JOURNAL OF MAGNETIC RESONANCE, 2007, 186 (02) : 252 - 258
  • [3] Improved Shinnar-Le Roux algorithm
    Ikonomidou, VN
    Sergiadis, GD
    JOURNAL OF MAGNETIC RESONANCE, 2000, 143 (01) : 30 - 34
  • [4] |B1+|-selective excitation pulse design using the Shinnar-Le Roux algorithm
    Grissom, William A. p
    Cao, Zhipeng
    Does, Mark D.
    JOURNAL OF MAGNETIC RESONANCE, 2014, 242 : 189 - 196
  • [5] Deep Reinforcement Learning Designed Shinnar-Le Roux RF Pulse Using Root-Flipping: DeepRFSLR
    Shin, Dongmyung
    Ji, Sooyeon
    Lee, Doohee
    Lee, Jieun
    Oh, Se-Hong
    Lee, Jongho
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (12) : 4391 - 4400
  • [6] Combined simulated annealing and Shinnar-Le Roux pulse design of slice-multiplexed RF pulses for multi-slice imaging
    Lee, K. J.
    Paley, M. N. J.
    Wild, J. M.
    JOURNAL OF MAGNETIC RESONANCE, 2006, 182 (01) : 133 - 142
  • [7] Optimized Shinnar-Le Roux RF 180° pulses in fast spin-echo measurements
    Raddi, A
    Klose, U
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (04): : 613 - 620
  • [8] Method for improved multiband excitation profiles using the Shinnar-Le Roux transform
    Cunningham, CH
    Wood, ML
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (03) : 577 - 584
  • [9] Slice Profile Experimental Comparison of Shinnar-Le Roux Pulse and SINC Pulse in Magnetic Resonance Imaging
    Gao, MingDa
    Yang, WenHui
    Wei, ShuFeng
    Tang, WenJu
    2016 8TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY IN MEDICINE AND EDUCATION (ITME), 2016, : 286 - 289
  • [10] Experimental Studies of the Shinnar-Le Roux Pulses in Slice Selection of MRI
    Liu, Y.
    PROCEEDINGS OF 2010 INTERNATIONAL SYMPOSIUM ON IMAGE ANALYSIS AND SIGNAL PROCESSING, 2010, : 290 - 291