Improved Shinnar-Le Roux algorithm

被引:11
|
作者
Ikonomidou, VN [1 ]
Sergiadis, GD [1 ]
机构
[1] Aristotelian Univ Salonika, Dept Elect & Comp Engn, Telecommun Div, Thessaloniki 54006, Greece
关键词
excitation; Shinnar-Le Roux algorithm; radiofrequency pulses; radiofrequency system; hardware implementation;
D O I
10.1006/jmre.1999.1965
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Selective excitation pulses are widely used in magnetic resonance imaging in order to excite predetermined slices of the body under examination. Such pulses are optimally designed by means of the Shinnar-Le Roux algorithm. In this paper, we show that under minimal assumptions, the complexity and computing cost of the original Shinnar-Le Roux algorithm can be drastically reduced. We further propose an improved version of the algorithm, involving only real quantities, which is both easier to implement and faster to execute, so it is suitable for implementation at the hardware level, in the context of a real-time fully digital magnetic resonance transceiver. (C) 2000 Academic Press.
引用
收藏
页码:30 / 34
页数:5
相关论文
共 50 条
  • [1] General parameter relations for the Shinnar-Le Roux pulse design algorithm
    Lee, Kuan J.
    JOURNAL OF MAGNETIC RESONANCE, 2007, 186 (02) : 252 - 258
  • [2] Design of Multidimensional Shinnar-Le Roux Radiofrequency Pulses
    Ma, Chao
    Liang, Zhi-Pei
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (02) : 633 - 645
  • [3] Designing Adiabatic Radio Frequency Pulses Using the Shinnar-Le Roux Algorithm
    Balchandani, Priti
    Pauly, John
    Spielman, Daniel
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (03) : 843 - 851
  • [4] Method for improved multiband excitation profiles using the Shinnar-Le Roux transform
    Cunningham, CH
    Wood, ML
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (03) : 577 - 584
  • [5] |B1+|-selective excitation pulse design using the Shinnar-Le Roux algorithm
    Grissom, William A. p
    Cao, Zhipeng
    Does, Mark D.
    JOURNAL OF MAGNETIC RESONANCE, 2014, 242 : 189 - 196
  • [6] Nonuniform and multidimensional Shinnar-Le Roux RF pulse design method
    Grissom, William A.
    McKinnon, Graeme C.
    Vogel, Mika W.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (03) : 690 - 702
  • [7] Experimental Studies of the Shinnar-Le Roux Pulses in Slice Selection of MRI
    Liu, Y.
    PROCEEDINGS OF 2010 INTERNATIONAL SYMPOSIUM ON IMAGE ANALYSIS AND SIGNAL PROCESSING, 2010, : 290 - 291
  • [8] Optimized Shinnar-Le Roux RF 180° pulses in fast spin-echo measurements
    Raddi, A
    Klose, U
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (04): : 613 - 620
  • [9] Slice Profile Experimental Comparison of Shinnar-Le Roux Pulse and SINC Pulse in Magnetic Resonance Imaging
    Gao, MingDa
    Yang, WenHui
    Wei, ShuFeng
    Tang, WenJu
    2016 8TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY IN MEDICINE AND EDUCATION (ITME), 2016, : 286 - 289
  • [10] Semi-adiabatic Shinnar-Le Roux pulses and their application to diffusion tensor imaging of humans at 7T
    Balchandani, Priti
    Qiu, Deqiang
    MAGNETIC RESONANCE IMAGING, 2014, 32 (07) : 804 - 812