Calculation of recovery coefficients for partial volume effect correction in PET/CT imaging using a customized anthropomorphic body phantom

被引:0
|
作者
Yavuz, Gunes [1 ]
Kovan, Bilal [2 ]
Toklu, Turkay [3 ]
Cermik, Tevfik F. [4 ]
Ozturk, Cengizhan [1 ,5 ]
机构
[1] Bogazici Univ, Inst Biomed Engn, Kandilli Campus, TR-34684 Istanbul, Turkiye
[2] Istanbul Univ, Istanbul Fac Med, Dept Nucl Med, Turgut Ozal Millet Cad 118U, TR-34104 Istanbul, Turkiye
[3] Yeditepe Univ, Kosuyolu Hosp, Dept Nucl Med, Kosuyolu Cad 168, TR-34718 Istanbul, Turkiye
[4] Acibadem Maslak Hosp, Dept Obstet & Gynecol, Buyukdere Cad 40, TR-34457 Istanbul, Turkiye
[5] Bogaz Univ, Ctr Targeted Therapy Technol CT3, Kandilli Campus, TR-34685 Istanbul, Turkiye
关键词
Partial volume effect; PVE; Partial volume effect correction; Anthropomorphic phantom; Recovery coefficients; PET/CT; Medical imaging; STRATEGIES;
D O I
10.1186/s12938-025-01330-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Positron Emission Tomography/Computed Tomography (PET/CT) combines metabolic and anatomical information improving the precision and accuracy of oncological diagnostics. The standardized uptake value (SUV) measures tumor metabolism, yet its accuracy is influenced by the partial volume effect (PVE), impacting small lesion detection. This study aims to refine PVE corrections for small lesions using an in-house customized, special anthropomorphic phantom. Scans of this phantom which contained spheres of different sizes were performed across four hospitals at different PET/CT systems from various manufacturers (Siemens and Philips analog PET/CT systems, GE analog and digital PET/CT systems). The phantom contained six custom-designed cylinders with embedded spheres simulating sub-centimeter (0.3, 0.5, 0.9) and centimeter (1.3, 1.9, 2.8) lesions. Scans were performed separately for each sphere in the thorax, abdomen, and pelvis regions at all sites. Recovery Coefficients (RCs) were calculated to correct SUV values, demonstrating that RCs vary by sphere size and anatomical region but not change significantly among scanners. RCs are approaching unity for larger spheres, ensuring accurate SUV measurements. However, small spheres (< 0.5 cm) exhibited significant measurement challenges due to PVE. The anthropomorphic phantom proved effective in obtaining realistic SUV-corrected values, offering a promising tool for enhancing the accuracy and standardization of PET imaging in oncology. This study underscores the necessity for advanced imaging technologies and standardized RC application in clinical settings to improve the quantification of PET imaging, particularly in small lesion detection.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Recovery coefficients determination for partial volume effect correction in oncological PET/CT images considering the effect of activity outside the field of view
    Krempser, Alexandre R.
    Ichinose, Roberto M.
    Miranda de Sa, Antonio M. F. L.
    Velasques de Oliveira, Silvia M.
    Carneiro, Michel P.
    ANNALS OF NUCLEAR MEDICINE, 2013, 27 (10) : 924 - 930
  • [2] Recovery coefficients determination for partial volume effect correction in oncological PET/CT images considering the effect of activity outside the field of view
    Alexandre R. Krempser
    Roberto M. Ichinose
    Antonio M. F. L. Miranda de Sá
    Silvia M. Velasques de Oliveira
    Michel P. Carneiro
    Annals of Nuclear Medicine, 2013, 27 : 924 - 930
  • [3] Coronary calcium scoring with partial volume correction in anthropomorphic thorax phantom and screening chest CT images
    Sprem, Jurica
    de Vos, Bob D.
    Lessmann, Nikolas
    van Hamersvelt, Robbert W.
    Greuter, Marcel J. W.
    de Jong, Pim A.
    Leiner, Tim
    Viergever, Max A.
    Isgum, Ivana
    PLOS ONE, 2018, 13 (12):
  • [4] Correction coefficients for partial volume effects of a PET/CT scanner: An empirical study
    Belakhlef, Sam
    Church, Clifford
    Lakhanpal, Suresh
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [5] Correction coefficients for partial volume effects of a PET/CT scanner: An empirical study
    Belakhlef, Sam
    Church, Clifford
    Lakhanpal, Suresh
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [6] Partial volume correction of lung nodules using PET/CT
    Bradley, W.
    Wendt, R.
    Pan, T.
    Erasmus, J.
    White, R.
    Mawlawi, O.
    MEDICAL PHYSICS, 2007, 34 (06) : 2553 - 2553
  • [7] Joint correction of respiratory motion artifact and partial volume effect in lung PET/CT imaging
    Chang, Guoping
    Chang, Tingting
    Clark, John
    Mawlawi, Osama
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [8] Partial-Volume Effect and a Partial-Volume Correction for the NanoPET/CT™ Preclinical PET/CT Scanner
    Szanda, Istvan
    Livieratos, Lefteris
    Patay, Gergely
    Tsoumpas, Charalampos
    Sunassee, Kavitha
    Mullen, Gregory E.
    Nemeth, Gabor
    Major, Peter
    Marsden, Paul K.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3605 - 3609
  • [9] Joint correction of respiratory motion artifact and partial volume effect in lung/thoracic PET/CT imaging
    Chang, Guoping
    Chang, Tingting
    Pan, Tinsu
    Clark, John W., Jr.
    Mawlawi, Osama R.
    MEDICAL PHYSICS, 2010, 37 (12) : 6221 - 6232
  • [10] Tracer effect on partial volume correction of Brain PET/MR imaging
    Balci, E.
    Akdemir, U.
    Atay, L. O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S20 - S20