Calculation of recovery coefficients for partial volume effect correction in PET/CT imaging using a customized anthropomorphic body phantom

被引:0
|
作者
Yavuz, Gunes [1 ]
Kovan, Bilal [2 ]
Toklu, Turkay [3 ]
Cermik, Tevfik F. [4 ]
Ozturk, Cengizhan [1 ,5 ]
机构
[1] Bogazici Univ, Inst Biomed Engn, Kandilli Campus, TR-34684 Istanbul, Turkiye
[2] Istanbul Univ, Istanbul Fac Med, Dept Nucl Med, Turgut Ozal Millet Cad 118U, TR-34104 Istanbul, Turkiye
[3] Yeditepe Univ, Kosuyolu Hosp, Dept Nucl Med, Kosuyolu Cad 168, TR-34718 Istanbul, Turkiye
[4] Acibadem Maslak Hosp, Dept Obstet & Gynecol, Buyukdere Cad 40, TR-34457 Istanbul, Turkiye
[5] Bogaz Univ, Ctr Targeted Therapy Technol CT3, Kandilli Campus, TR-34685 Istanbul, Turkiye
关键词
Partial volume effect; PVE; Partial volume effect correction; Anthropomorphic phantom; Recovery coefficients; PET/CT; Medical imaging; STRATEGIES;
D O I
10.1186/s12938-025-01330-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Positron Emission Tomography/Computed Tomography (PET/CT) combines metabolic and anatomical information improving the precision and accuracy of oncological diagnostics. The standardized uptake value (SUV) measures tumor metabolism, yet its accuracy is influenced by the partial volume effect (PVE), impacting small lesion detection. This study aims to refine PVE corrections for small lesions using an in-house customized, special anthropomorphic phantom. Scans of this phantom which contained spheres of different sizes were performed across four hospitals at different PET/CT systems from various manufacturers (Siemens and Philips analog PET/CT systems, GE analog and digital PET/CT systems). The phantom contained six custom-designed cylinders with embedded spheres simulating sub-centimeter (0.3, 0.5, 0.9) and centimeter (1.3, 1.9, 2.8) lesions. Scans were performed separately for each sphere in the thorax, abdomen, and pelvis regions at all sites. Recovery Coefficients (RCs) were calculated to correct SUV values, demonstrating that RCs vary by sphere size and anatomical region but not change significantly among scanners. RCs are approaching unity for larger spheres, ensuring accurate SUV measurements. However, small spheres (< 0.5 cm) exhibited significant measurement challenges due to PVE. The anthropomorphic phantom proved effective in obtaining realistic SUV-corrected values, offering a promising tool for enhancing the accuracy and standardization of PET imaging in oncology. This study underscores the necessity for advanced imaging technologies and standardized RC application in clinical settings to improve the quantification of PET imaging, particularly in small lesion detection.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Partial Volume Correction Using Continuous Wavelet Technique in Small Animal PET Imaging
    Arhjoul, Lahcen
    Sarrhini, Otman
    Bentourkia, M'hamed
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2717 - 2721
  • [22] Low-Noise Correction of Partial Volume Effect in whole body FDG-PET
    Korkola, P.
    Tohka, J.
    Koskinen, M. O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S312 - S312
  • [23] Correction of partial-volume effect for PET striatal imaging:: Fast implementation and study of robustness
    Frouin, V
    Comtat, C
    Reilhac, A
    Grégoire, MC
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (12) : 1715 - 1726
  • [24] Towards optimal model-based partial volume effect correction in oncological PET imaging
    Schoenahl, F
    Zaidi, H
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3177 - 3181
  • [25] Comparison of PET reconstruction resolution recovery and post-reconstruction deconvolution for partial volume effect correction (PVC) in PET
    Le Pogam, Adrien
    Alessio, Adam
    Kandel, Benjamin
    Kirov, Assen
    Barret, Olivier
    Fernandez, Philippe
    Le Rest, Catherine Cheze
    Visvikis, Dimitris
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [26] A Correction of Partial Volume Effect for Using PET to Define Metabolically Active Tumor Volume for Pancreatic Cancer
    Dalah, E.
    Cungeng, Y.
    Moraru, I.
    Erickson, B.
    Li, X.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [27] Phantom Validation of a Conservation of Activity-Based Partial Volume Correction Method for Arterial Input Function in Dynamic PET Imaging
    Driscoll, Brandon
    Shek, Tina
    Vines, Douglass
    Sun, Alex
    Jaffray, David
    Yeung, Ivan
    TOMOGRAPHY, 2022, 8 (02) : 842 - 857
  • [28] Partial volume effect correction in PET image using iterative deconvolution and shearlet transform
    Jomaa, Hajer
    Mabrouk, Rostom
    Khlifa, Nawres
    2018 4TH INTERNATIONAL CONFERENCE ON ADVANCED TECHNOLOGIES FOR SIGNAL AND IMAGE PROCESSING (ATSIP), 2018,
  • [29] 18FDG-PET Partial volume correction using a recovery coefficient approach based on functional volume and contrast
    Anouan, Koutoua
    Lelandais, Benoit
    Ruan, Su
    Vera, Pierre
    Gardin, Isabelle
    Hapdey, Sebastien
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [30] Impact of partial volume correction in whole-body PET imaging: a computer-aided detection study
    Lartizien, C.
    Marache-Francisco, S.
    Le Pogam, A.
    Tomei, S.
    Visvikis, D.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3214 - +