Robust optimization for PPG-based blood pressure estimation

被引:0
|
作者
Lim, Sungjun [1 ]
Kim, Taero [2 ]
Lee, Hyeonjeong [3 ]
Kim, Yewon [1 ]
Park, Minhoi [4 ]
Kim, Kwang-Yong [3 ]
Kim, Minseong [3 ]
Kim, Kyu Hyung [3 ]
Jung, Jiyoung [1 ]
Song, Kyungwoo [5 ]
机构
[1] Department of Artificial Intelligence, University of Seoul, Korea, Republic of
[2] Department of Statistics and Data Science, Yonsei University, Korea, Republic of
[3] Daegu-Gyeongbuk Research Division, Electronics and Telecommunications Research Institute (ETRI), Korea, Republic of
[4] Institute of Data Science, Yonsei University, Korea, Republic of
[5] Department of Applied Statistics, Department of Statistics and Data Science, Yonsei University, Korea, Republic of
基金
新加坡国家研究基金会;
关键词
D O I
10.1016/j.bspc.2025.107585
中图分类号
学科分类号
摘要
Machine learning-based estimation of blood pressure (BP) using photoplethysmography (PPG) signals has gained significant attention for its non-invasive nature and potential for continuous monitoring. However, challenges remain in real-world applications, where performance can vary widely across different BP groups, especially among high-risk groups. This study is the first to propose a PPG-based BP estimation approach that specifically accounts for BP group disparities, aiming to improve robustness for high-risk BP groups.We present a comprehensive approach from the perspectives of data, model, and loss to enhance overall accuracy and reduce performance degradation for specific groups, referred to as worst groups. At the data level, we introduce in-group augmentation using Time-Cutmix to mitigate group imbalance severity. From a model perspective, we adopt a hybrid structure of convolutional and Transformer layers to integrate local and global information, improving average model performance. Additionally, we propose robust optimization techniques that consider data quantity and label distributions within each group. These methods effectively minimize performance loss for high-risk groups without compromising average and worst-group performance. Experimental results demonstrate the effectiveness of our methods in developing a robust BP estimation model tailored to handle group-based performance disparities. © 2025 Elsevier Ltd
引用
收藏
相关论文
共 50 条
  • [21] Robust PPG-Based Mental Workload Assessment System Using Wearable Devices
    Beh, Win-Ken
    Wu, Yi-Hsuan
    Wu, An-Yeu
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2023, 27 (05) : 2323 - 2333
  • [22] PPG-Based Heart Rate Estimation Using Unsupervised Domain Adaptation
    Kim, Jihyun
    Lee, Minjung
    Cho, Hansam
    Kim, Seoung Bum
    ADVANCES AND TRENDS IN ARTIFICIAL INTELLIGENCE: THEORY AND APPLICATIONS, IEA-AIE 2024, 2024, 14748 : 291 - 296
  • [23] PPG-Based Blood Pressure Monitoring by Pulse Wave Analysis: Calibration Parameters are Stable for Three Months
    Proenca, Martin
    Bonnier, Guillaume
    Ferrario, Damien
    Verjus, Christophe
    Lemay, Mathieu
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 5560 - 5563
  • [24] Robust and Energy-efficient PPG-based Heart-Rate Monitoring
    Risso, Matteo
    Burrello, Alessio
    Pagliari, Daniele Jahier
    Benatti, Simone
    Macii, Enrico
    Benini, Luca
    Pontino, Massimo
    2021 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2021,
  • [25] Improved peak detection technique for robust PPG-based heartrate monitoring system on smartphones
    Jean-Pierre Lomaliza
    Hanhoon Park
    Multimedia Tools and Applications, 2018, 77 : 17131 - 17155
  • [26] PaWLA: PPG-based Weight Lifting Assessment
    Rahman, A. B. M. Mohaimenur
    Wang, Pu
    Wang, Weichao
    Wang, Yu
    2022 IEEE INTERNATIONAL PERFORMANCE, COMPUTING, AND COMMUNICATIONS CONFERENCE, IPCCC, 2022,
  • [27] Schrodinger Spectrum Based PPG Features for the Estimation of the Arterial Blood Pressure
    Li, Peihao
    Laleg-Kirati, Taous-Meriem
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 2683 - 2686
  • [28] Improved peak detection technique for robust PPG-based heartrate monitoring system on smartphones
    Lomaliza, Jean-Pierre
    Park, Hanhoon
    MULTIMEDIA TOOLS AND APPLICATIONS, 2018, 77 (13) : 17131 - 17155
  • [29] PPG-based blood pressure estimation can benefit from scalable multi-scale fusion neural networks and multi-task learning
    Hu, Qihan
    Wang, Daomiao
    Yang, Cuiwei
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 78
  • [30] Effect of Position and Fastening Belt Pressure on the Accuracy of PPG-Based Heart Rate Sensor
    Shimazaki, Takunori
    Kuwahara, Yuzu
    Kimoto, Masaya
    Hara, Shinsuke
    Yomo, Hiroyuki
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 4323 - 4326