PPG-Based Blood Pressure Monitoring by Pulse Wave Analysis: Calibration Parameters are Stable for Three Months

被引:0
|
作者
Proenca, Martin [1 ]
Bonnier, Guillaume [1 ]
Ferrario, Damien [1 ]
Verjus, Christophe [1 ]
Lemay, Mathieu [1 ]
机构
[1] Ctr Suisse Elect & Microtech CSEM, Swiss Ctr Elect & Microtechnol, Neuchatel, Switzerland
关键词
D O I
10.1109/embc.2019.8857740
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The current non-invasive gold standard for the measurement of blood pressure (BP) is the oscillometric cuff at the upper arm, despite its known limitations. In particular, its poor adequacy with continuous monitoring and its measurement incommodity call for the development of simpler and more convenient solutions. Among these, solutions based on pulse wave analysis (PWA) and photoplethysmography (PPG) are of particular interest, due to their low-cost, strong patient compliance, and applicability in and out of clinical settings. In that context, we have recently disclosed a PPG-based PWA algorithm (oBPM (TM)) dedicated to the continuous monitoring of BP in patients undergoing induction of general anesthesia. As is standard with PPG-based BP monitoring techniques, an initial calibration procedure with a reference device is required to allow the estimation of absolute values of BP (in mmHg). However, due to their sensitivity to peripheral effects such as vasomotion, the applicability of PPG-based techniques is often limited by the constant need of re-calibration procedures, sometimes in matters of minutes. In the present study, we evaluated the long-term stability of the calibration for our algorithm by performing PPG measurements at irregular time intervals over a period of 3 months in 13 healthy volunteers. For each measurement, diastolic BP (DBP) was assessed by an oscillometric device and estimated by the oBPM (TM) algorithm. We found the calibration to remain stable over the entire 3-month period, with estimation errors remaining stable over time and complying with the ISO 81060-2:2018 standard. In addition, we verified - in 11 of our 13 subjects - the sensitivity of the oBPM (TM) algorithm to changes in DBP. This was done in a protocol involving static leg extension exercises. Excellent trending ability (average per-subject concordance rate of 97.7 +/- 5.2 %, and correlation coefficient of 0.98 +/- 0.02, p < 0.001) was found between cuff-derived DBP changes and our estimates. These findings provide a strong added value to the practical usability of the proposed PPG-based PWA approach to BP monitoring, particularly for the clinical management of hypertensive patients in and out of clinics, for whom a simple and comfortable continuous alternative to the oscillometric cuff would be strongly preferred.
引用
收藏
页码:5560 / 5563
页数:4
相关论文
共 50 条
  • [1] A Novel Form Factor For PPG-based Blood Pressure Monitoring
    Alawieh, Hussein
    Weiss, Neil
    [J]. 2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [2] BLOOD PRESSURE ESTIMATION FROM PPG-BASED PULSE ARRIVAL TIME
    Villeneuve, Emma
    Anglade, Daniel
    Sandre-ballester, Caroline
    Auclair, Loic
    Fuchs, Olivier
    Blandin, Pierre
    [J]. JOURNAL OF HYPERTENSION, 2024, 42
  • [3] Blood pressure acquisitions with a prototypal PPG-based device
    Scardulla, Francesco
    Montinaro, Nicola
    D'Acquisto, Leonardo
    [J]. PROCEEDINGS OF 2022 IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR INDUSTRY 4.0 & IOT (IEEE METROIND4.0&IOT), 2022, : 414 - 418
  • [4] Continuous PPG-Based Blood Pressure Monitoring Using Multi-Linear Regression
    Haddad, Serj
    Boukhayma, Assim
    Caizzone, Antonino
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (05) : 2096 - 2105
  • [5] Single-source PPG-based local pulse wave velocity measurement: a potential cuffless blood pressure estimation technique
    Nabeel, P. M.
    Jayaraj, J.
    Mohanasankar, S.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2017, 38 (12) : 2122 - 2140
  • [6] A Pulse Wave Based Blood Pressure Monitoring and Analysis Algorithm
    Liu, Yue
    Sun, Xin
    Sun, Yongmei
    Zhang, Kuixing
    Hong, Yanfei
    Wei, Benzheng
    [J]. ARTIFICIAL INTELLIGENCE (ICAI 2018), 2018, 888 : 211 - 221
  • [7] A PPG-Based Calibration-Free Cuffless Blood Pressure Estimation Method Using Cardiovascular Dynamics
    Samimi, Hamed
    Dajani, Hilmi R.
    [J]. SENSORS, 2023, 23 (08)
  • [8] Reflective PPG-based Noninvasive Continuous Pulse Rate Measurement and Remote Monitoring System
    Mukherjee, Ramtanu
    Ghosh, Sanchita
    Gupta, Bharat
    Chakravarty, Tapas
    [J]. 2017 GLOBAL WIRELESS SUMMIT (GWS), 2017, : 193 - 197
  • [9] Improved PPG-based estimation of the blood pressure using latent space features
    Atefe Hassani
    Amir Hossein Foruzan
    [J]. Signal, Image and Video Processing, 2019, 13 : 1141 - 1147
  • [10] Improved PPG-based estimation of the blood pressure using latent space features
    Hassani, Atefe
    Foruzan, Amir Hossein
    [J]. SIGNAL IMAGE AND VIDEO PROCESSING, 2019, 13 (06) : 1141 - 1147