A Novel Form Factor For PPG-based Blood Pressure Monitoring

被引:0
|
作者
Alawieh, Hussein [1 ]
Weiss, Neil [1 ]
机构
[1] Meta Real Labs Res, Redmond, WA 98052 USA
关键词
CUFF-LESS; TIME;
D O I
10.1109/EMBC40787.2023.10341192
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Blood pressure (BP) is one of the four main vital signs in medicine and may be a useful signal for wellness tracking and for user-aware interfaces in human-computer interaction. The current standard for BP measurement uses cuff-based devices that block an artery temporarily to get a single, discrete measurement of BP. Recently, there have been significant efforts to measure correlates of BP continuously and non-invasively from relevant signals like photoplethysmography (PPG), which responds to volumetric changes in arteries due to blood pulsations. In this paper, we explore a novel setup with two points of instrumentation, one on the head and a second on the wrist, for recording PPG and estimating the pulse wave velocity, which is a major correlate of BP, along with other waveform-related features. We prospectively tested the device on 10 subjects who followed a protocol for the deliberate variation of BP while ground truth measurements were taken using a reference cuff-device. Generic absolute BP models, which use the collected data for leave-one-subject-out cross-validation, yielded an error of -0.14 +/- 7.3 mmHg for systolic BP (SBP) and -0.21 +/- 6.7 mmHg for diastolic BP (DBP), which are within the regulatory limits of 5 +/- 8 mmHg. Notably, the correlation between the predicted BPs and the ground truth BPs was higher for SBP (r = 0.74, p < 0.001) than for DBP (r = 0.34, p < 0.001). The results show that the proposed form factor can extract BP-related features that could be used for continuous, cuff-less BP monitoring.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Blood pressure acquisitions with a prototypal PPG-based device
    Scardulla, Francesco
    Montinaro, Nicola
    D'Acquisto, Leonardo
    [J]. PROCEEDINGS OF 2022 IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR INDUSTRY 4.0 & IOT (IEEE METROIND4.0&IOT), 2022, : 414 - 418
  • [2] Continuous PPG-Based Blood Pressure Monitoring Using Multi-Linear Regression
    Haddad, Serj
    Boukhayma, Assim
    Caizzone, Antonino
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (05) : 2096 - 2105
  • [3] BLOOD PRESSURE ESTIMATION FROM PPG-BASED PULSE ARRIVAL TIME
    Villeneuve, Emma
    Anglade, Daniel
    Sandre-ballester, Caroline
    Auclair, Loic
    Fuchs, Olivier
    Blandin, Pierre
    [J]. JOURNAL OF HYPERTENSION, 2024, 42
  • [4] PPG-Based Blood Pressure Monitoring by Pulse Wave Analysis: Calibration Parameters are Stable for Three Months
    Proenca, Martin
    Bonnier, Guillaume
    Ferrario, Damien
    Verjus, Christophe
    Lemay, Mathieu
    [J]. 2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 5560 - 5563
  • [5] Improved PPG-based estimation of the blood pressure using latent space features
    Atefe Hassani
    Amir Hossein Foruzan
    [J]. Signal, Image and Video Processing, 2019, 13 : 1141 - 1147
  • [6] Improved PPG-based estimation of the blood pressure using latent space features
    Hassani, Atefe
    Foruzan, Amir Hossein
    [J]. SIGNAL IMAGE AND VIDEO PROCESSING, 2019, 13 (06) : 1141 - 1147
  • [7] Evaluating and Visualizing the Contribution of ECG Characteristic Waveforms for PPG-Based Blood Pressure Estimation
    Ma, Gang
    Chen, Yuhang
    Zhu, Wenliang
    Zheng, Lesong
    Tang, Hui
    Yu, Yong
    Wang, Lirong
    [J]. MICROMACHINES, 2022, 13 (09)
  • [8] Continuous maternal hemodynamics monitoring at delivery using a novel, noninvasive, wireless, PPG-based sensor
    Atzmon, Yuval
    Ben-Ishai, Efrat
    Hallak, Mordechai
    Gabbay-Benziv, Rinat
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2020, 222 (01) : S184 - S185
  • [9] Continuous Maternal Hemodynamics Monitoring at Delivery Using a Novel, Noninvasive, Wireless, PPG-Based Sensor
    Atzmon, Yuval
    Ben Ishay, Efrat
    Hallak, Mordechai
    Littman, Romi
    Eisenkraft, Arik
    Gabbay-Benziv, Rinat
    [J]. JOURNAL OF CLINICAL MEDICINE, 2021, 10 (01) : 1 - 11
  • [10] Toward IoT-Based Medical Edge Devices: PPG-Based Blood Pressure Estimation Application
    Bernard, Denis
    Msigwa, Constantino
    Yun, Jaeseok
    [J]. IEEE INTERNET OF THINGS JOURNAL, 2023, 10 (06) : 5240 - 5255