Continuous Maternal Hemodynamics Monitoring at Delivery Using a Novel, Noninvasive, Wireless, PPG-Based Sensor

被引:12
|
作者
Atzmon, Yuval [1 ,2 ]
Ben Ishay, Efrat [3 ]
Hallak, Mordechai [1 ,2 ]
Littman, Romi [3 ]
Eisenkraft, Arik [3 ,4 ,5 ]
Gabbay-Benziv, Rinat [1 ,2 ]
机构
[1] Hillel Yaffe Med Ctr, Obstet & Gynecol Dept, IL-38100 Hadera, Israel
[2] Technion, Rappaport Fac Med, IL-32000 Haifa, Israel
[3] Biobeat Technol Ltd, POB 12272, IL-44425 Petah Tiqwa, Israel
[4] Hebrew Univ Jerusalem, Fac Med, Inst Res Mil Med, IL-9112102 Jerusalem, Israel
[5] Israel Def Force Med Corps, IL-9112102 Jerusalem, Israel
关键词
remote patient monitoring; noninvasive monitoring; delivery; maternal hemodynamics; CARDIAC-OUTPUT; INTRATHECAL FENTANYL; PREGNANCY; CATHETERIZATION; HEART; LABOR;
D O I
10.3390/jcm10010008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate continuous monitoring of maternal hemodynamics during labor and delivery utilizing an innovative, noninvasive, reflective photoplethysmography-based device. Study design: The Biobeat Monitoring Platform includes a wearable wristwatch monitor that automatically samples cardiac output (CO), blood pressure (BP), stroke volume (SV), systemic vascular resistance (SVR), heart rate (HR) every 5 s and uploads all data to a smartphone-based app and to a data cloud, enabling remote patient monitoring and analysis of data. Low-risk parturients at term, carrying singletons pregnancies, were recruited at early delivery prior to the active phase. Big data analysis of the collected data was performed using the Power BI analysis tool (Microsoft). Next, data were normalized to visual presentation using Excel Data Analysis and the regression tool. Average measurements were compared before and after rupture of membranes, epidural anesthesia, fetal delivery, and placental expulsion. Results: Eighty-one parturients entered analysis. Epidural anesthesia was associated with a slight elevation in CO (5.5 vs. 5.6, L/min, 10 min before and after EA, p < 0.05) attributed to a non-significant increase in both HR and SV. BP remained stable as of counter decrease in SVR (1361 vs. 1319 mmHg.min.mL(-1), 10 min before and after EA, p < 0.05). Fetal delivery was associated with a peak in CO after which it rapidly declined (6.0 vs. 7.2 vs. 6.1 L/min, 30 min before vs. point of delivery vs. after delivery, p < 0.05). The mean BP remained stable throughout delivery with a slight increase at fetal delivery (92 vs. 95 vs. 92.1 mmHg, p < 0.05), reflecting the increase in CO and decrease in SVR (1284 vs. 1112 vs. 1280 mmHg.min.mL(-1), p < 0.05)with delivery. Placental expulsion was associated with a second peak in CO and decrease in SVR. Conclusions: We presented a novel application of noninvasive hemodynamic maternal monitoring throughout labor and delivery for both research and clinical use.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [1] Continuous maternal hemodynamics monitoring at delivery using a novel, noninvasive, wireless, PPG-based sensor
    Atzmon, Yuval
    Ben-Ishai, Efrat
    Hallak, Mordechai
    Gabbay-Benziv, Rinat
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2020, 222 (01) : S184 - S185
  • [2] Epidural effect on maternal hemodynamics using a novel, wireless, PPG-based sensor for continuous non-invasive monitoring
    Atzmon, Yuval
    Ben-Ishai, Efrat
    Hallak, Mordechai
    Gabbay-Benziv, Rinat
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2020, 222 (01) : S482 - S483
  • [3] Maternal age impact on hemodynamic monitoring at delivery evaluated by a novel non-invasive PPG-based sensor
    Atzmon, Yuval
    Ben Ishay, Efrat
    Eisenkraft, Erik
    Hallak, Mordechai
    Gabbay-Benziv, Rinat
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2021, 224 (02) : S244 - S245
  • [4] Reflective PPG-based Noninvasive Continuous Pulse Rate Measurement and Remote Monitoring System
    Mukherjee, Ramtanu
    Ghosh, Sanchita
    Gupta, Bharat
    Chakravarty, Tapas
    [J]. 2017 GLOBAL WIRELESS SUMMIT (GWS), 2017, : 193 - 197
  • [5] Noninvasive Continuous Mobile Blood Pressure Monitoring using Novel PPG Optical Sensor
    Mouradian, Vahram
    Poghosyan, Armen
    Hovhannisyan, Levon
    [J]. 2015 IEEE TOPICAL CONFERENCE ON BIOMEDICAL WIRELESS TECHNOLOGIES, NETWORKS, AND SENSING SYSTEMS (BIOWIRELESS), 2015, : 60 - 62
  • [6] Continuous PPG-Based Blood Pressure Monitoring Using Multi-Linear Regression
    Haddad, Serj
    Boukhayma, Assim
    Caizzone, Antonino
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (05) : 2096 - 2105
  • [7] Maternal obesity and hemodynamic adaptation to epidural anesthesia: evaluation using a novel non-invasive PPG-based sensor
    Atzmon, Yuval
    Ben Ishay, Efrat
    Eisenkraft, Erik
    Hallak, Mordechai
    Gabbay-Benziv, Rinat
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2021, 224 (02) : S245 - S245
  • [8] A Novel Form Factor For PPG-based Blood Pressure Monitoring
    Alawieh, Hussein
    Weiss, Neil
    [J]. 2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [9] Live Demonstration: A Single LED PPG-based Noninvasive Glucose Monitoring Prototype System
    Hina, Aminah
    Nadeem, Hamza
    Aslam, Abdul Rehman
    Saadeh, Wala
    [J]. 2019 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2019,
  • [10] Continuous Wearable Health Monitoring using Novel PPG Optical Sensor and Device
    Mouradian, Vahram
    Poghosyan, Amen
    Hovhannisyan, Levon
    [J]. 2014 IEEE 10TH INTERNATIONAL CONFERENCE ON WIRELESS AND MOBILE COMPUTING, NETWORKING AND COMMUNICATIONS (WIMOB), 2014, : 120 - 123