Improved peak detection technique for robust PPG-based heartrate monitoring system on smartphones

被引:6
|
作者
Lomaliza, Jean-Pierre [1 ]
Park, Hanhoon [1 ]
机构
[1] Pukyong Natl Univ, Dept Elect Engn, Busan 48513, South Korea
基金
新加坡国家研究基金会;
关键词
Peak detection; Heartratemonitoring; Photo-plethysmography; Smartphone; Healthcare; HEALTH INFORMATICS;
D O I
10.1007/s11042-017-5282-9
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Heartrate monitoring can be very decisive in terms of detecting heart-related diseases in early stages. Given that smartphones are used almost ubiquitously by humans on a daily basis and that they are equipped with several sensors and a powerful CPU, they are the ideal tools to accomplish daily heartrate monitoring. Many studies have shown the possibility of monitoring the heartrate in a very accurate way by using smartphone camera and the photo-plethysmography technique. However, in real cases, when using a smartphone camera as the input sensor, the pulse signal usually contains noise caused by fingertip movements, pressure changes between the smartphone camera and the fingertip, or changes in ambient light intensity. Hence, many techniques have been proposed to filter and detect real peaks in the pulse signal and avoid noise peaks. Most of those state-of-the-art techniques rely on the assumption that real peaks are those having the maximum values in their respective cycles. In some cases, the assumption is not correct, which decreases the accuracy of peak detection. Hence, this paper proposes a novel method to detect a pulse signal's real peaks. The proposed method first smoothens a pulse signal by using a second-order Butterworth band-pass filter over a wide frequency range. Then, it considers the local minima of the signal as peaks and builds an optimization tree based on statistical properties, such as uniformity of peak time locations, peak count within a period, and variance in times elapsed between adjacent peaks, to detect combinations of peaks that optimize the heartrate computation. Results from experiments conducted using synthetic and real signals show that the proposed method can detect a pulse signal's real peaks with higher precision as compared to conventional methods, and is very robust to signal noises. The proposed method has a significant heartrate estimation accuracy in various real scenarios and across smartphone models; its error rate is as low as 0.8588 +/- 0.0653 beats per minute, even in cases of signals with extensive noise.
引用
收藏
页码:17131 / 17155
页数:25
相关论文
共 50 条
  • [1] Improved peak detection technique for robust PPG-based heartrate monitoring system on smartphones
    Jean-Pierre Lomaliza
    Hanhoon Park
    [J]. Multimedia Tools and Applications, 2018, 77 : 17131 - 17155
  • [2] ROBUST REAL-TIME PPG-BASED HEART RATE MONITORING
    Nowak, Ewelina
    Krainski, Mateusz
    Rubinski, Maciej
    Pazderska, Marta
    Raczynski, Stanislaw A.
    [J]. 2015 23RD EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2015, : 2561 - 2565
  • [3] Robust and Energy-efficient PPG-based Heart-Rate Monitoring
    Risso, Matteo
    Burrello, Alessio
    Pagliari, Daniele Jahier
    Benatti, Simone
    Macii, Enrico
    Benini, Luca
    Pontino, Massimo
    [J]. 2021 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2021,
  • [4] Robust PPG-Based Mental Workload Assessment System Using Wearable Devices
    Beh, Win-Ken
    Wu, Yi-Hsuan
    Wu, An-Yeu
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2023, 27 (05) : 2323 - 2333
  • [5] A 0.5V PPG-based Heart Rate and Variability Detection System
    Saadeh, Wala
    Aslam, Shah Zaib
    Hina, Aminah
    Asghar, Fakeha
    [J]. 2018 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): ADVANCED SYSTEMS FOR ENHANCING HUMAN HEALTH, 2018, : 53 - 56
  • [6] Robust PPG-based Ambulatory Heart Rate Tracking Algorithm
    Huang, Nicholas
    Selvaraj, Nandakumar
    [J]. 42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 5929 - 5934
  • [7] Reliable PPG-based Algorithm in Atrial Fibrillation Detection
    Shan, Shih-Ming
    Tang, Sung-Chun
    Huang, Pei-Wen
    Lin, Yu-Min
    Huang, Wei-Han
    Lai, Dar-Ming
    Wu, An-Yeu
    [J]. PROCEEDINGS OF 2016 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2016, : 340 - 343
  • [8] Towards PPG-based anger detection for emotion regulation
    Tuck-Voon How
    Robin E. A. Green
    Alex Mihailidis
    [J]. Journal of NeuroEngineering and Rehabilitation, 20
  • [9] Towards PPG-based anger detection for emotion regulation
    How, Tuck-Voon
    Green, Robin E. A.
    Mihailidis, Alex
    [J]. JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2023, 20 (01)
  • [10] Reflective PPG-based Noninvasive Continuous Pulse Rate Measurement and Remote Monitoring System
    Mukherjee, Ramtanu
    Ghosh, Sanchita
    Gupta, Bharat
    Chakravarty, Tapas
    [J]. 2017 GLOBAL WIRELESS SUMMIT (GWS), 2017, : 193 - 197