Design, Development, and Characterization of Cross Beam Force Transducer for Low Force Measurement

被引:0
|
作者
Vikas [1 ,2 ]
Titus, S. S. K. [1 ]
Kumar, R. [1 ]
Gautam, S. K. [1 ]
机构
[1] Natl Phys Lab, Force & Hardness Metrol Sect, CSIR, Dr KS Krishnan Marg, New Delhi 110012, India
[2] Acad Sci & Innovat Res AcSIR, Human Resource Dev Ctr, CSIR, Ghaziabad 201002, UP, India
来源
关键词
Low Force Measurement; Cross Beam; Finite Element Analysis; Metrology; Strain Gauge; NONLINEARITY;
D O I
10.1007/s12647-024-00784-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This study addresses the growing need for precise static low-force measurement in industries and metrology, driven by technological advancements and a trend toward miniaturization. Existing commercially available static force transducers can do force measurements with precision but these transducers face significant challenges in their development for low force measurement due to the irregular shapes of the spring element. Additionally, in the literature, some low-force sensors are also described for static low-force measurement but they possess poor metrology characteristics such as linearity, repeatability, and reproducibility which impacts their overall performance. The use of such low-force sensors in static low force measurements related applications such as microhardness testing, tactile sensing, and automation assembly systems may lead to low product trustworthiness. To address these challenges, this study presents the design of a simple-shaped cross-beam low-force transducer specifically for static force measurement in the 5 N range. The study begins with the design of cross beam spring element whose deflection under 5 N is analyzed by analytical and computational means. For the computational analysis, Ansys software of Finite Element Analysis (FEA) is used. For the analytical analysis, an analytical expression is derived to study the deflection. Experimental results demonstrate that the developed cross-beam strain gauge force transducer exhibits good metrological performance in the low-force range.
引用
收藏
页码:127 / 137
页数:11
相关论文
共 50 条
  • [21] Combined magnetoelastic transducer for torque and force measurement
    Zakrzewski, J
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1997, 46 (04) : 807 - 810
  • [22] A new magnetoelastic transducer for torque and force measurement
    Zakrzewski, J
    JOINT CONFERENCE - 1996: IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE & IMEKO TECHNICAL COMMITTEE 7, CONFERENCE PROCEEDINGS, VOLS I AND II: QUALITY MEASUREMENTS: THE INDISPENSABLE BRIDGE BETWEEN THEORY AND REALITY (NO MEASUREMENTS? NO SCIENCE!), 1996, : 497 - 501
  • [23] Papillary Muscle Force Transducer for Measurement In Vivo
    Askov J.B.
    Honge J.L.
    Nygaard H.
    Hasenkam J.M.
    Nielsen S.L.
    Jensen M.O.
    Cardiovascular Engineering and Technology, 2011, 2 (3) : 196 - 202
  • [24] Measurement of steep impulse response of a force transducer
    Fujii, Y
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (01) : 65 - 69
  • [25] MEASUREMENT OF MYOCYTE FORCE USING A NEW MICRO-ELECTROMECHANICAL FORCE TRANSDUCER
    LIN, G
    PALMER, RE
    PISTER, KSJ
    ROOS, KP
    CIRCULATION, 1995, 92 (08) : 1533 - 1533
  • [26] DESIGN AND APPLICATIONS OF A NEW SHEAR FORCE TRANSDUCER
    HAGGSTROM, RP
    MICROTECNIC, 1972, 26 (04): : 240 - +
  • [27] Design and construction of a transducer for bite force registration
    Isaza, Juan F.
    Throckmorton, Gaylord S.
    Roldan, Samuel I.
    JOURNAL OF BIOMECHANICS, 2009, 42 (08) : 1146 - 1149
  • [28] Design of adaptive filter for the wheel force transducer
    Wang, Dong
    Li, Xuanpeng
    Fen, Lihang
    Xu, Yang
    MEASUREMENT, 2018, 125 : 526 - 534
  • [29] DEVELOPMENT OF AN IMPLANTABLE HEART VALVE FORCE TRANSDUCER
    Jensen, Morten O.
    Johansen, Peter
    Nygaard, Hans
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2008, PTS A AND B, 2009, : 247 - 248
  • [30] Development and Metrological Evaluation of an Industrial Force Transducer
    Ajay P. Singh
    Sanjoy K. Ghoshal
    Harish Kumar
    MAPAN, 2020, 35 : 165 - 176