Numerical Response of Concrete-Filled Steel Tubular (CFST) Columns Externally Strengthened with FRP Composites Subjected to Cyclic Loading

被引:0
|
作者
Mansour, Walid [1 ,2 ]
Osama, Bothaina [3 ]
Li, Weiwen [1 ]
Wang, Peng [1 ,3 ]
Sobuz, Md. Habibur Rahman [4 ]
机构
[1] Shenzhen Univ, Guangdong Prov Key Lab Durabil Marine Civil Engn, Shenzhen 518060, Peoples R China
[2] Kafrelsheikh Univ, Fac Engn, Civil Engn Dept, Kafrelsheikh, Egypt
[3] Hong Kong Univ Sci & Technol, Dept Civil & Environm Engn, Hong Kong, Peoples R China
[4] Khulna Univ Engn & Technol, Dept Bldg Engn & Construct Management, Khulna 9203, Bangladesh
关键词
Concrete-filled steel tubular (CFST) columns; Cyclic loading; Finite element model; Fiber-reinforced polymers (FRPs); Absorbed energy; Stiffness; Viscous damping; FIBER-REINFORCED CONCRETE; SEISMIC BEHAVIOR; STUB COLUMNS; CONFINED CONCRETE; PERFORMANCE; STRESS; STRAIN; DUCTILITY; DESIGN; MODEL;
D O I
10.1186/s40069-024-00716-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The ultimate load-carrying capacity of concrete-filled steel tubular (CFST) columns exposed to monotonic loadings can be greatly increased by strengthening those columns, and the occurrence of the steel tube's outward buckling can be postponed. The current research aims to study the possibility of improving the structural characteristics of CFST columns exposed to cyclic loadings in terms of lateral load capacity and absorbed energy by strengthening them with different patterns of fiber-reinforced polymer (FRP) sheets. The ABAQUS software was used to create a three-dimensional (3D) non-linear finite element model (FEM) to simulate the behavior of FRP-strengthened CFST columns exposed to monotonic and cyclic loadings. After ascertaining the accuracy of the proposed model's results in successfully predicting failure patterns and lateral loads compared to the experimental results of tested specimens available in the literature, the model was used to create a parametric study. The parametric study focused on the impacts of the thickness, location, and length of the strengthening sheets on the failure pattern, lateral load-carrying capacity, stiffness, cumulative energy, absorbed energy, and viscous damping factor of the CFST columns exposed to cyclic loadings. The results revealed that the un-strengthened specimen displayed a maximum lateral load of 185 kN and a viscous damping factor of 45.2% at a lateral drift of 5.7%. On the other hand, strengthening the CFST column using five layers of FRP sheets exhibited the highest lateral load of all investigated columns (50% more than the un-strengthened specimen). Additionally, at a lateral drift of 5.7%, the decrease in viscous damping factor of CFST specimens due to strengthening using 1, 2, 3, 4, and 5 layers of FRP sheets with respect to the control specimen was 7.9%, 14.9%, 20.8%, 27.7%, and 30.3%, respectively.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Tests on inclined, tapered and STS concrete-filled steel tubular (CFST) stub columns
    Han, Lin-Hai
    Ren, Qing-Xin
    Li, Wei
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (10) : 1186 - 1195
  • [32] Investigation of cyclic behavior of partially concrete-filled steel tubular columns
    Gan, Dan
    Zhang, Yaojun
    Zhou, Xuhong
    Zhang, Xingjiang
    ENGINEERING STRUCTURES, 2024, 300
  • [33] Behaviors of concrete-filled steel tubular members subjected to combined loading
    Han, Lin-Hai
    Yao, Guo-Huang
    Tao, Zhong
    THIN-WALLED STRUCTURES, 2007, 45 (06) : 600 - 619
  • [34] Experimental research on pultruded concrete-filled GFRP tubular short columns externally strengthened with CFRP
    Guo, Zhan
    Xue, Xiaolei
    Ye, Mengya
    Chen, Yu
    Li, Zhihui
    COMPOSITE STRUCTURES, 2021, 255 (255)
  • [35] Behaviour of concrete filled steel tubular columns subjected to repeated loading
    Thirugnanasundralingam, K
    Thayalan, P
    Patnaikuni, I
    MECHANICS OF STRUCTURES AND MATERIALS, 1997, : 165 - 170
  • [36] Recycled concrete-filled steel tubular columns
    Yang, You-Fu
    Han, Lin-Hai
    Advances in Structural Engineering:Theory and Applications Vols 1 and 2, 2006, : 1508 - 1515
  • [37] Concrete-filled double skin steel tubular (CFDST) beam-columns subjected to cyclic bending
    Han, Lin-Hai
    Huang, Hong
    Tao, Zhong
    Zhao, Xiao-Ling
    ENGINEERING STRUCTURES, 2006, 28 (12) : 1698 - 1714
  • [38] Numerical Simulation Parametric Studies on Concrete-Filled Steel Tubular Columns
    Zhao, Lidong
    Cao, Wanlin
    Ye, Taopin
    5TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND CIVIL ENGINEERING (ESCE2019), 2019, 283
  • [39] DUCTILITY OF CONCRETE-FILLED STEEL BOX COLUMNS UNDER CYCLIC LOADING
    USAMI, T
    GE, HB
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1994, 120 (07): : 2021 - 2040
  • [40] Concrete-Filled Steel Tubular (CFTS) Columns Subjected to Eccentric Compressive Load
    Kedziora, Slawomir
    Anwaar, Muhammad Omer
    PROCEEDINGS OF THE 15TH STABILITY OF STRUCTURES SYMPOSIUM, 2019, 2060