Numerical Response of Concrete-Filled Steel Tubular (CFST) Columns Externally Strengthened with FRP Composites Subjected to Cyclic Loading

被引:0
|
作者
Mansour, Walid [1 ,2 ]
Osama, Bothaina [3 ]
Li, Weiwen [1 ]
Wang, Peng [1 ,3 ]
Sobuz, Md. Habibur Rahman [4 ]
机构
[1] Shenzhen Univ, Guangdong Prov Key Lab Durabil Marine Civil Engn, Shenzhen 518060, Peoples R China
[2] Kafrelsheikh Univ, Fac Engn, Civil Engn Dept, Kafrelsheikh, Egypt
[3] Hong Kong Univ Sci & Technol, Dept Civil & Environm Engn, Hong Kong, Peoples R China
[4] Khulna Univ Engn & Technol, Dept Bldg Engn & Construct Management, Khulna 9203, Bangladesh
关键词
Concrete-filled steel tubular (CFST) columns; Cyclic loading; Finite element model; Fiber-reinforced polymers (FRPs); Absorbed energy; Stiffness; Viscous damping; FIBER-REINFORCED CONCRETE; SEISMIC BEHAVIOR; STUB COLUMNS; CONFINED CONCRETE; PERFORMANCE; STRESS; STRAIN; DUCTILITY; DESIGN; MODEL;
D O I
10.1186/s40069-024-00716-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The ultimate load-carrying capacity of concrete-filled steel tubular (CFST) columns exposed to monotonic loadings can be greatly increased by strengthening those columns, and the occurrence of the steel tube's outward buckling can be postponed. The current research aims to study the possibility of improving the structural characteristics of CFST columns exposed to cyclic loadings in terms of lateral load capacity and absorbed energy by strengthening them with different patterns of fiber-reinforced polymer (FRP) sheets. The ABAQUS software was used to create a three-dimensional (3D) non-linear finite element model (FEM) to simulate the behavior of FRP-strengthened CFST columns exposed to monotonic and cyclic loadings. After ascertaining the accuracy of the proposed model's results in successfully predicting failure patterns and lateral loads compared to the experimental results of tested specimens available in the literature, the model was used to create a parametric study. The parametric study focused on the impacts of the thickness, location, and length of the strengthening sheets on the failure pattern, lateral load-carrying capacity, stiffness, cumulative energy, absorbed energy, and viscous damping factor of the CFST columns exposed to cyclic loadings. The results revealed that the un-strengthened specimen displayed a maximum lateral load of 185 kN and a viscous damping factor of 45.2% at a lateral drift of 5.7%. On the other hand, strengthening the CFST column using five layers of FRP sheets exhibited the highest lateral load of all investigated columns (50% more than the un-strengthened specimen). Additionally, at a lateral drift of 5.7%, the decrease in viscous damping factor of CFST specimens due to strengthening using 1, 2, 3, 4, and 5 layers of FRP sheets with respect to the control specimen was 7.9%, 14.9%, 20.8%, 27.7%, and 30.3%, respectively.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] Analysis of steel-reinforced concrete-filled steel tubular (SRCFST) columns under cyclic loading
    Chang, Xu
    Wei, You-Yi
    Yun, Yan-Chun
    CONSTRUCTION AND BUILDING MATERIALS, 2012, 28 (01) : 88 - 95
  • [22] Compound concrete-filled FRP tubular columns under cyclic axial compression
    Zhou, J. K.
    Lin, Guan
    Teng, J. G.
    COMPOSITE STRUCTURES, 2021, 275
  • [23] Study on seismic behavior of concrete-filled rectangular steel tubular columns under cyclic loading
    Wang Lai
    Wang Tiecheng
    8th International Conference on Steel-Concrete Composite and Hybrid Structures, Proceedings, 2006, : 695 - 701
  • [24] Experimental Behavior of Concrete-Filled Stainless Steel Tubular Columns under Cyclic Lateral Loading
    Liao, Fei-Yu
    Han, Lin-Hai
    Tao, Zhong
    Rasmussen, Kim J. R.
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (04)
  • [25] Tests of Inclined Concrete-Filled Steel Tubular Stub Columns under Vertical Cyclic Loading
    Hansapinyo, Chayanon
    Buachart, Chinnapat
    Chaimahawan, Preeda
    ADVANCES IN CIVIL ENGINEERING, 2018, 2018
  • [26] Numerical analysis on circular concrete-filled tubular columns subjected to fire
    Pires, Tiago A. de C.
    Rodrigues, Joao Paulo C.
    Silva, Jose J. R.
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2019, 10 (01) : 2 - 23
  • [27] FRP-confined circular concrete-filled steel tubular columns under cyclic axial compression
    Yu, T.
    Hu, Y. M.
    Teng, J. G.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 94 : 33 - 48
  • [28] Seismic behavior of fire-exposed concrete-filled steel tubular (CFST) columns
    Li, Shuai
    Han, Lin-Hai
    Wang, Fa-Cheng
    Hou, Chuan-Chuan
    Han, Lin-Hai (lhhan@tsinghua.edu.cn), 1600, Elsevier Ltd (224):
  • [29] Analysis of strengthened short deficient rubberized concrete-filled steel tubular columns
    Elshazly, Fady A.
    Mustafa, Suzan A. A.
    Fawzy, Hesham M.
    FRATTURA ED INTEGRITA STRUTTURALE, 2021, 15 (55): : 1 - 19
  • [30] Seismic behavior of fire-exposed concrete-filled steel tubular (CFST) columns
    Li, Shuai
    Han, Lin-Hai
    Wang, Fa-Cheng
    Hou, Chuan-Chuan
    ENGINEERING STRUCTURES, 2020, 224