Concrete-filled double skin steel tubular (CFDST) beam-columns subjected to cyclic bending

被引:197
|
作者
Han, Lin-Hai [1 ]
Huang, Hong
Tao, Zhong
Zhao, Xiao-Ling
机构
[1] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
[2] China Educ Minist, Key Lab Struct Engn & Vibrat, Beijing 100084, Peoples R China
[3] Fuzhou Univ, Coll Civil Engn, Fuzhou 350002, Fujian, Peoples R China
[4] Monash Univ, Dept Civil Engn, Clayton, Vic 3168, Australia
基金
中国国家自然科学基金;
关键词
composite beam-columns; concrete; seismic design; cyclic load; ductility; strength; hollow sections; double-skin; mechanics model;
D O I
10.1016/j.engstruct.2006.03.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent years, it was proposed by several researchers that concrete filled double skin steel tubes (CFDST) be studied for their strength as a column or a beam. Advantages of CFDST over fully concrete filled steel tubes (CFST) include: increase in section modulus; enhancement in stability; lighter weight; better damping characteristics and better cyclic performance. It is thus expected that concrete filled double skin steel tubes (CFDST) have the potential of being used in building structures. This paper provides new test data pertaining to the seismic behavior of CFDST beam-columns. The test parameters included the section types (circular and square), the core concrete strength (f(cu)), and the axial load level (n). Twenty-eight CFDST column specimens, including 16 specimens with SHS (square hollow section) outer and CHS (circular hollow section) inner, 12 specimens with CHS (circular hollow section) outer and CHS (circular hollow section) inner were tested under constant axial load and cyclically increasing flexural loading. The CFDST beam-columns were found to have significant increase in strength, ductility, and dissipated energy over the outer jackets. In general, the ductility and energy dissipation ability of specimens with circular sections are higher than those of the specimens with square sections. The mechanics model which was developed by the authors for concrete filled steel tubular (CFST) beam-columns subjected to constant axial load and cyclically increasing flexural loading, is used to analyze the behavior of CFDST beam-columns. It is found that the predicted cyclic responses for the composite beam-columns are generally in reasonable agreement with test results. Finally; comparisons are made with predicted beam-column flexural stiffness using the existing codes. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1698 / 1714
页数:17
相关论文
共 50 条
  • [1] Analytical behaviour of concrete-filled double skin steel tubular (CFDST) beam-columns under cyclic loading
    Han, Lin-Hai
    Huang, Hong
    Zhao, Xiao-Ling
    [J]. THIN-WALLED STRUCTURES, 2009, 47 (6-7) : 668 - 680
  • [2] Behavior of Concrete-filled Double-skin Stainless Steel Tubular Beam-columns Subjected to Cyclic Loading
    Xu, Wenchao
    Zhou, Feng
    [J]. 2016 INTERNATIONAL CONFERENCE ON ARCHITECTURE AND CIVIL ENGINEERING (ICACE 2016), 2016, : 416 - 421
  • [3] Behaviour of concrete-filled double skin rectangular steel tubular beam-columns
    Tao, Zhong
    Han, Lin-Hai
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2006, 62 (07) : 631 - 646
  • [4] Behavior of concrete-filled double skin rectangular steel tubular beam-columns
    Wang, Zhi-Bin
    Tao, Zhong
    Han, Lin-Hai
    [J]. Advances in Structural Engineering:Theory and Applications Vols 1 and 2, 2006, : 1448 - 1453
  • [5] Concrete-filled double skin steel tubular (CFDST) columns subjected to long-term sustained loading
    Han, Lin-Hai
    Li, Yong-Jin
    Liao, Fei-Yu
    [J]. THIN-WALLED STRUCTURES, 2011, 49 (12) : 1534 - 1543
  • [6] Experimental investigation of concrete-filled double-skin stainless steel tubular beam-columns
    Zhou, Feng
    Li, Yingfei
    Dong, Baiping
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 196
  • [7] Research on the Concrete-Filled Double Skin steel Tubular (CFDST) columns subjected to axial force after fire
    Liu, Xiao
    Liu, Zhaohui
    Hui, Yanchuan
    Wang, Jie
    [J]. STRUCTURES, 2023, 57
  • [8] Behaviour of tapered concrete-filled double skin steel tubular (CFDST) stub columns
    Li, Wei
    Ren, Qing-Xin
    Han, Lin-Hai
    Zhao, Xiao-Ling
    [J]. THIN-WALLED STRUCTURES, 2012, 57 : 37 - 48
  • [9] Analytical behaviour of concrete-filled double skin steel tubular (CFDST) stub columns
    Huang, Hong
    Han, Lin-Hai
    Tao, Zhong
    Zhao, Xiao-Ling
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (04) : 542 - 555
  • [10] Behavior of concrete-filled double skin steel tube beam-columns
    Hassan, Maha M.
    Mahmoud, Ahmed A.
    Serror, Mohammed H.
    [J]. STEEL AND COMPOSITE STRUCTURES, 2016, 22 (05): : 1141 - 1162