RECORDING EFFICIENCY OF NaI(Tl) CRYSTALS FOR gamma RADIATION OF HOLLOW CYLINDRICAL SOURCES.

被引:0
|
作者
Yasyulenis, R.Yu. [1 ]
机构
[1] Acad of Sciences of the Lithuanian, SSR, Inst of Physics, Vilnius, USSR, Acad of Sciences of the Lithuanian SSR, Inst of Physics, Vilnius, USSR
来源
关键词
CRYSTALS - Radiation Effects;
D O I
暂无
中图分类号
学科分类号
摘要
The recording efficiency of gamma radiation is examined for direct measurement of the concentrations of radionuclides deposited on cylindrical aerosol filters or the walls of air ducts or pipes that are coaxial with cylindrical crystals. Analytic solutions are obtained and recording efficiencies are calculated for a hollow cylindrical source with a diam of 50 cm and a length of 50 cm and standard scintillation crystals.
引用
收藏
页码:584 / 587
相关论文
共 50 条
  • [41] Calibration of cylindrical NaI(Tl) gamma-ray detector intended for truncated conical radioactive source
    Badawi, Mohamed S.
    Thabet, Abouzeid A.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (04) : 1421 - 1430
  • [42] PHOTOPEAK EFFICIENCY AND RESPONSE FUNCTION OF VARIOUS NAI(TL) AND CSI(TL) CRYSTALS IN THE ENERGY RANGE UP TO 11 MEV
    JARCZYK, L
    KNOEPFEL, H
    LANG, J
    MULLER, R
    WOLFLI, W
    NUCLEAR INSTRUMENTS & METHODS, 1962, 17 (03): : 310 - 320
  • [43] Direct mathematical method for calculating the photofraction and intrinsic efficiency of 4πNaI(Tl) borehole cylindrical detectors
    Noureldine, Salam F.
    Nader, Richard R.
    JOURNAL OF TAIBAH UNIVERSITY FOR SCIENCE, 2016, 10 (02): : 182 - 186
  • [44] Gamma-Ray Source Positioning Using Array NaI(Tl) Detectors in the Radiation Portal Monitors
    Qibiao Wang
    Chao Deng
    Jianbo Yang
    Rui Shi
    Songbai Zhang
    Xianguo Tuo
    Journal of the Korean Physical Society, 2019, 75 : 196 - 201
  • [45] Gamma-Ray Source Positioning Using Array NaI(Tl) Detectors in the Radiation Portal Monitors
    Wang, Qibiao
    Deng, Chao
    Yang, Jianbo
    Shi, Rui
    Zhang, Songbai
    Tuo, Xianguo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2019, 75 (03) : 196 - 201
  • [46] Monte Carlo calculation of response functions to gamma-ray point sources for a spherical NaI(Tl) detector
    Yi, Chul-Young
    Hah, Suck-Ho
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 2133 - 2136
  • [47] Calculation of full-energy peak efficiency of NaI (Tl) detectors by new analytical approach for parallelepiped sources
    El-Khatib, Ahmed M.
    Badawi, Mohamed S.
    Gouda, Mona M.
    Jovanovic, Slobodan I.
    Dlabac, Aleksandar D.
    Mihaljevic, Nikola N.
    Nafee, Sherif S.
    El-Mallah, Ekram A.
    JOURNAL OF THEORETICAL AND APPLIED PHYSICS, 2013, 7 (01)
  • [48] SCINTILLATION COUNTER WITH A RECORDING EFFICIENCY PROPORTIONAL TO THE ENERGY OF gamma RADIATION.
    Bergman, A.A.
    Kolosovskii, A.G.
    Kuznetsov, S.P.
    Medvedev, A.N.
    Samsonov, A.E.
    Instruments and experimental techniques New York, 1981, 24 (3 pt 1): : 601 - 604
  • [49] DETERMINATION OF PROBABILITY OF TOTAL DETECTION OF NAI(TL) WELL-HOLE CRYSTAL FOR SOURCES EMITTING GAMMA QUANTA IN COINCIDENCE
    CHRISTMANN, B
    NUCLEAR INSTRUMENTS & METHODS, 1971, 95 (03): : 541 - +
  • [50] Moving NaI(Tl) gamma counters towards improved quantitative accuracy for PET applications using traceable calibration sources
    Lodge, Martin
    Kinahan, Paul
    Wahl, Richard
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55