RECORDING EFFICIENCY OF NaI(Tl) CRYSTALS FOR gamma RADIATION OF HOLLOW CYLINDRICAL SOURCES.

被引:0
|
作者
Yasyulenis, R.Yu. [1 ]
机构
[1] Acad of Sciences of the Lithuanian, SSR, Inst of Physics, Vilnius, USSR, Acad of Sciences of the Lithuanian SSR, Inst of Physics, Vilnius, USSR
来源
关键词
CRYSTALS - Radiation Effects;
D O I
暂无
中图分类号
学科分类号
摘要
The recording efficiency of gamma radiation is examined for direct measurement of the concentrations of radionuclides deposited on cylindrical aerosol filters or the walls of air ducts or pipes that are coaxial with cylindrical crystals. Analytic solutions are obtained and recording efficiencies are calculated for a hollow cylindrical source with a diam of 50 cm and a length of 50 cm and standard scintillation crystals.
引用
收藏
页码:584 / 587
相关论文
共 50 条
  • [21] Calculation of the full-energy peak efficiency of NaI(Tl) detector using the efficiency transfer method for large radioactive cylindrical sources
    El-Khatib, Ahmed. M.
    Gouda, Mona. M.
    Badawi, Mohamed. S.
    Hamzawy, A.
    Hussien, Nancy. S.
    Abbas, Mahmoud. I.
    CHINESE JOURNAL OF PHYSICS, 2016, 54 (04) : 592 - 606
  • [22] Temporal Fluctuations in Indoor Background Gamma Radiation Using NaI(Tl)
    Smith, Travis
    Cao, Sana
    Kearfott, Kimberlee J.
    HEALTH PHYSICS, 2018, 114 (03): : 360 - 372
  • [23] CALCULATED EFFICIENCIES OF NAI (TL) SCINTILLATION CRYSTALS FOR MARINELLI BEAKERS WITH AQUEOUS SOURCES
    VERHEIJK.ML
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1970, 21 (03): : 119 - &
  • [24] EVALUATION OF TOTAL ABSOLUTE EFFICIENCIES FOR NAI(TL) CYLINDRICAL AND WELL-TYPE CRYSTALS
    IONESCU, C
    REVUE ROUMAINE DE PHYSIQUE, 1969, 14 (10): : 1135 - &
  • [25] ANALYTIC CALCULATION OF PHOTOFRACTIONS FOR NAI(TL) SCINTILLATION CRYSTALS TO MONOENERGETIC GAMMA-RAYS
    KAMINISHI, K
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1979, 18 (03) : 423 - 428
  • [27] NaI(Tl) Detector Efficiency Computation Using Radioactive Parallelepiped Sources Based on Efficiency Transfer Principle
    Badawi, Mohamed S.
    Gouda, Mona M.
    El-Khatib, Ahmed M.
    Thabet, Abouzeid A.
    Salim, Ahmed A.
    Abbas, Mahmoud I.
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2015, 2015
  • [28] Calculation of the efficiency for cylindrical volume sources in gamma spectrometry
    Haase, G
    Tait, D
    Wiechen, A
    KERNTECHNIK, 1997, 62 (2-3) : 109 - 112
  • [29] Radiation hazards of the moassel consumed in Baghdad/Iraq using NaI(Tl) gamma spectroscopy
    Kadhim, N. F.
    Ridha, A. A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2019, 16 (12) : 8209 - 8216
  • [30] Radioactive source strength effect on gamma radiation monitoring with a NaI (Tl) scintillation detector
    Yeboah, E.
    Yakovlev, G. A.
    Smirnov, S. V.
    Yakovleva, V. S.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (05)