Gamma-Ray Source Positioning Using Array NaI(Tl) Detectors in the Radiation Portal Monitors

被引:1
|
作者
Wang, Qibiao [1 ,2 ]
Deng, Chao [1 ]
Yang, Jianbo [2 ]
Shi, Rui [1 ]
Zhang, Songbai [1 ]
Tuo, Xianguo [1 ,2 ]
机构
[1] Sichuan Univ Sci & Engn, Zigong 643000, Peoples R China
[2] Chengdu Univ Technol, Coll Nucl Technol & Automat Engn, Chengdu 610059, Sichuan, Peoples R China
关键词
RPMs; Source positioning; Monte Carlo; NaI(Tl) detector;
D O I
10.3938/jkps.75.196
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Radiation portal monitors (RPMs) are globally employed in ports to decrease the illicit trafficking of nuclear materials. Most RPMs are generally considered as threshold devices because they utilize large plastic scintillators, which have limited energy resolution and no position sensitivity, to count the gamma-rays and neutrons emitted by nuclear materials. Hence, we designed an RPM detector system with NaI(Tl) detectors inserted into the plastic scintillators to realize gamma-ray source identification and positioning. In this work, a 2D gamma-ray source positioning algorithm based on the attenuation law and solidangle variation was studied with the simulation results, and the variation of the positioning deviations with the real positions was spline interpolated to calibrate the calculated position. The testing experiment showed a small root mean square error (RMSE) for both x (0.86 cm) and y (1.52 cm) after calibration.
引用
收藏
页码:196 / 201
页数:6
相关论文
共 50 条
  • [1] Gamma-Ray Source Positioning Using Array NaI(Tl) Detectors in the Radiation Portal Monitors
    Qibiao Wang
    Chao Deng
    Jianbo Yang
    Rui Shi
    Songbai Zhang
    Xianguo Tuo
    Journal of the Korean Physical Society, 2019, 75 : 196 - 201
  • [2] IMAGING EFFICIENCY OF GE AND NAI(TL) GAMMA-RAY DETECTORS
    STRAUSS, MG
    SHERMAN, IS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1975, NS22 (01) : 331 - 343
  • [3] Implementation of gamma-ray spectrometry in two real-time water monitors using NaI(Tl) scintillation detectors
    Casanovas, R.
    Morant, J. J.
    Salvado, M.
    APPLIED RADIATION AND ISOTOPES, 2013, 80 : 49 - 55
  • [4] GAMMA-RAY MEASUREMENTS WITH NAI(TL) CRYSTALS
    HOFSTADTER, R
    MCINTYRE, JA
    PHYSICAL REVIEW, 1950, 79 (02): : 389 - 391
  • [5] A MULTI NAI(TL) DETECTOR ARRAY FOR MEDIUM ENERGY GAMMA-RAY SPECTROSCOPY
    AGARWAL, YK
    BABA, CVK
    CHAKRABARTY, DR
    DATAR, VM
    GOTHE, DA
    JAIN, HC
    ROY, A
    SHARAN, MK
    PRAMANA-JOURNAL OF PHYSICS, 1990, 35 (01): : 49 - 65
  • [7] Principal Component Analysis of Gamma-Ray Spectra for Radiation Portal Monitors
    Boardman, David
    Reinhard, Mark
    Flynn, Alison
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (01) : 154 - 160
  • [8] MEASUREMENT OF GAMMA-RAY ENERGIES WITH CRYSTALS OF NAI(TL)
    HOFSTADTER, R
    MCINTYRE, JA
    PHYSICAL REVIEW, 1950, 80 (01): : 131 - 131
  • [9] GAMMA-RAY ABSORPTION-COEFFICIENTS FOR NAI(TL)
    MANNHART, W
    VONACH, H
    NUCLEAR INSTRUMENTS & METHODS, 1976, 134 (02): : 347 - 351
  • [10] Performance of NaI(Tl) detector for gamma-ray spectroscopy
    Akkurt, Iskender
    Waheed, Faez
    Akyildirim, Hakan
    Gunoglu, Kadir
    INDIAN JOURNAL OF PHYSICS, 2022, 96 (10) : 2941 - 2947