Measuring system of absorbed dose standard for electron beam radiation processing

被引:0
|
作者
Zhang, Limin [1 ]
Gu, Jiqing [1 ]
Xu, Peiling [1 ]
Bai, Yihua [1 ]
Ye, Dongsheng [1 ]
Wu, Bin [1 ]
机构
[1] Shanghai Inst of Metrological, Technology, Shanghai, China
来源
He Jishu/Nuclear Techniques | 1995年 / 18卷 / 04期
关键词
Absorption - Dosimetry - Electron beams - Measurements - Processing - Radiation;
D O I
暂无
中图分类号
学科分类号
摘要
The design and experiments of an absorbed dose calorimeter in quasi-adiabatic mode of operation and its measuring system were described. The absorption disk and outer shell of the calorimeter were made of anisotropic pyrolytic graphite. The graphite itself was used as heating resistor of the electrical heating unit, for the purpose of check and simulation. The ratio of calculated value and experimental one for temperature rising is 1.008. The standard deviation is less than 0.6%. The total uncertainty of absorbed dose determination with the graphite calorimeter approximates to 2.7% (K=2) for the 0.5-3.0 MeV electron beam in the dose range of 1-5×102kGy. the powder alanine/ESR dosimeter and plastic thin-film dosimeter can be calibrated by the calorimeter. The passivation of temperature rising curve, heat equilibrium, measurement of calorimetric ratio and its error were also discussed.
引用
收藏
页码:238 / 246
相关论文
共 50 条
  • [21] EXCHANGE OF SOURCES, BEAM FLATTENING FILTERS AND JIGS OF A SECONDARY STANDARD FOR ABSORBED DOSE-RATES OF BETA-RADIATION
    BOHM, J
    PTB-MITTEILUNGEN, 1986, 96 (05): : 317 - 319
  • [22] DETERMINATION OF THE AVERAGE ABSORBED ENERGY OF ELECTRONS BEAM IN OBJECTS AT RADIATION PROCESSING
    Lazurik, V. T.
    Lazurik, V. M.
    Popov, G. Ph
    Zimek, Z.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2019, (06): : 134 - 137
  • [23] The UK primary standard calorimeter for photon-beam absorbed dose measurement
    DuSautoy, AR
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (01): : 137 - 151
  • [24] A direct-charging detector for measuring the pulse shape, absorbed dose rate, and γ-radiation dose
    Gryzun, V.N.
    Katraev, G.G.
    Chernyshev, A.K.
    Pribory i Tekhnika Eksperimenta, 2002, 45 (03): : 101 - 106
  • [25] A direct-charging detector for measuring the pulse shape, absorbed dose rate, and γ-radiation dose
    Gryzun, VN
    Katraev, GG
    Chernyshev, AK
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2002, 45 (03) : 384 - 389
  • [26] A Direct-Charging Detector for Measuring the Pulse Shape, Absorbed Dose Rate, and γ-Radiation Dose
    V. N. Gryzun
    G. G. Katraev
    A. K. Chernyshev
    Instruments and Experimental Techniques, 2002, 45 : 384 - 389
  • [27] WORKING STANDARD FOR UNIT OF ABSORBED DOSE OF PHOTON IONIZING-RADIATION IN WATER
    BERLYAND, VA
    BREGADZE, YI
    TSURIEV, SMS
    MEASUREMENT TECHNIQUES USSR, 1986, 29 (04): : 345 - 349
  • [28] DOSE EVALUATION IN ELECTRON-BEAM PROCESSING
    TANAKA, R
    SUNAGA, H
    YOTSUMOTO, K
    MIZUHASHI, K
    TAMURA, N
    RADIATION PHYSICS AND CHEMISTRY, 1981, 18 (5-6): : 927 - 936
  • [29] WATER CALORIMETER FOR MEASURING PHOTON-RADIATION ABSORBED DOSE-RATES
    BERLYAND, VA
    BREGADZE, YI
    MEASUREMENT TECHNIQUES USSR, 1985, 28 (12): : 1100 - 1103
  • [30] WATER CALORIMETER FOR MEASURING PHOTON-RADIATION ABSORBED DOSE RATES.
    Berlyand, V.A.
    Bregadze, Yu.I.
    Measurement Techniques, 1985, 28 (12) : 1100 - 1103