Pulse Pressure Method and the Area Method for the Estimation of Total Arterial Compliance in Dogs: Sensitivity to Wave Reflection Intensity

被引:0
|
作者
Segers, Patrick
Verdonck, Pascal
Deryck, Yvon
Brimioulle, Serge
Naeije, Robert
Carlier, Stephane
Stergiopulos, Nikos
机构
[1] Hydraulics Laboratory, IBITECH, University of Gent, Sint-Pietersnieuwstraat 41, 9000 Gent, Belgium
[2] Cardiac Anesthesia, University Hospital of Gent, De Pintelaan 185, 9000 Gent, Belgium
[3] Lab. Cardiovasc. and Resp. Physiol., Free University of Brussels, Brussels, Belgium
[4] Cleveland Clinic Foundation, Cleveland, OH, United States
[5] Biomedical Engineering Laboratory, EPFL, Swiss Fed. Institute of Technology, Lausanne, Switzerland
[6] Hydraulics Laboratory, Institute Biomedical Technology, University of Gent, Sint-Pietersnieuwstraat 41, B-9000 Gent, Belgium
来源
关键词
This research is funded by a specialization grant of the Flemish Institute for the Promotion of the Scientific-Technological Research in Industry (IWT 943065—IWT 960250); a concerted action program of the University of Gent; supported by the Flemish Government (GOA 95003); and the Fonds de la Recherche Scientifique Medicale (Grant No. 3.4537.91). Dr. Carlier was the recipient of a grant from NATO and the Belgian American Educational Foundation;
D O I
暂无
中图分类号
学科分类号
摘要
16
引用
下载
收藏
页码:480 / 485
相关论文
共 50 条
  • [31] Total arterial compliance estimated by stroke volume to aortic pulse pressure ratio in humans
    Chemla, D
    Hébert, JL
    Coirault, C
    Zamani, K
    Suard, I
    Colin, P
    Lecarpentier, Y
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 274 (02): : H500 - H505
  • [32] A novel method for vascular age estimation via pressure pulse wave of radial artery
    Tang, Qingfeng
    Tao, Changlong
    Pan, Zhiqiang
    Wang, Guangjun
    Liu, Kui
    Pan, Zhigeng
    Liu, Guodong
    Su, Benyue
    Liu, Ning
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 78
  • [33] 2.1 A Method for the Measurement of Pressure Sensitivity of Carotid-Femoral Pulse Wave Velocity in Humans
    Mark Butlin
    Alberto Avolio
    Artery Research, 2015, 12 (1) : 40 - 41
  • [34] P134 A New Method for Non-invasive Measurement of Arterial Wave Intensity, Speed and Reflection
    Ethan Rowland
    Kai Riemer
    Kevin Lichtenstein
    Mengxing Tang
    Peter Weinberg
    Artery Research, 2019, 25 (Suppl 1) : S172 - S172
  • [35] YI 1.1 Aortic Impedance and Total Arterial Compliance from Regional Pulse Wave Velocities
    Vasiliki Bikia
    Georgios Rovas
    Stamatia Pagoulatou
    Nikolaos Stergiopulos
    Artery Research, 2020, 26 (Suppl 1) : S1 - S1
  • [36] P2.45 Estimating Total Arterial Compliance From Aortic Pulse Wave Velocity
    O. Vardoulis
    T. G. Papaioannou
    N. Stergiopulos
    Artery Research, 2012, 6 (4) : 176 - 176
  • [38] Cardiology of cats and dogs - Measuring arterial pressure with the Doppler method
    Chetboul, PV
    POINT VETERINAIRE, 2002, 33 (224): : 12 - 13
  • [39] Arterial blood pressure in dogs by the oscilometric method and the Doppler ultrasonic
    Cabral, R. R.
    Ciasca, B. D.
    Oliveira, V. M. C.
    Vaz-Curado, A. P.
    Larsson, M. H. M. A.
    ARQUIVO BRASILEIRO DE MEDICINA VETERINARIA E ZOOTECNIA, 2010, 62 (01) : 64 - 71
  • [40] The Vibration Plethysmographic Method of Arterial Compliance Analysis in Dependence on Transmural Pressure
    Moudr, J.
    Svacinova, J.
    Zavodna, E.
    Honzikova, N.
    PHYSIOLOGICAL RESEARCH, 2014, 63 : S489 - S495