Total arterial compliance estimated by stroke volume to aortic pulse pressure ratio in humans

被引:344
|
作者
Chemla, D
Hébert, JL
Coirault, C
Zamani, K
Suard, I
Colin, P
Lecarpentier, Y
机构
[1] Ecole Polytech, Ensta, Loa, INSERM,U451, F-91125 Palaiseau, France
[2] Univ Paris 11, Hop Bicetre, Serv Physiol Cardioresp, F-94275 Le Kremlin Bicetre, France
[3] Hop Antoine Beclere, Serv Cardiol, F-92141 Clamart, France
关键词
heart period; ventricular-arterial coupling; wave reflection;
D O I
10.1152/ajpheart.1998.274.2.H500
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
On the basis of the windkessel model, the stroke volume-to-aortic pulse pressure ratio (SV/PP) has been proposed as an estimate of total arterial compliance, but recent studies have questioned this approximation. Aortic pressure was obtained at rest in 31 adults undergoing cardiac catheterization (47 +/- 14 yr): controls (n = 7), patients with dilated cardiomyopathy (n = 10), and patients with other cardiac diseases (n = 14). me calculated PP, mean aortic pressure (MAoP), heart period (T), SV (thermodilution cardiac output/ heart rate), total peripheral resistance (R), total arterial compliance estimated by area method (C-area), and the time constant of aortic pressure decay in diastole (RCarea). In the overall population (n = 31), there was no significant difference between SV/PP and C-area. SV/PP was linearly related to C-area (SV/PP = 0.99C(area) + 0.05; r = 0.98; P < 0,001); the slope and intercept did not differ fr om unity and zero, respectively. Similar results were obtained in the three subgroups. These results implied that PP/MAoP and T/RCarea, were proportionally related (T/RCarea = 1.18PP/MAoP - 0.07; r = 0.96; P < 0.001). We conclude that for humans at rest reliable estimate of C-area and 2) T normalized by the time constant of aortic pressure decay in diastole was proportionally related to PP/MAoP. This last relationship could be considered an aspect of the coupling between the left ventricle and its load.
引用
收藏
页码:H500 / H505
页数:6
相关论文
共 50 条
  • [1] RELIABILITY OF STROKE VOLUME TO PULSE PRESSURE RATIO FOR ESTIMATING AND DETECTING CHANGES IN ARTERIAL COMPLIANCE
    RANDALL, OS
    WESTERHOF, N
    VANDENBOS, GC
    ALEXANDER, B
    JOURNAL OF HYPERTENSION, 1986, 4 : S293 - S296
  • [2] Arterial compliance in patients with cirrhosis: stroke volume-pulse pressure ratio as simplified index
    Henriksen, JH
    Fuglsang, S
    Bendtsen, F
    Christensen, E
    Moller, S
    AMERICAN JOURNAL OF PHYSIOLOGY-GASTROINTESTINAL AND LIVER PHYSIOLOGY, 2001, 280 (04): : G584 - G594
  • [3] The ratio of pulse pressure/stroke volume index, a marker of total arterial compliance: Its correlation with abnormal left ventricular geometry
    Manela, David
    Levine, Jason
    Klapholz, Marc
    CIRCULATION, 2006, 114 (18) : 668 - 668
  • [4] Stroke volume pulse pressure ratio and cardiovascular risk in arterial hypertension
    de Simone, G
    Roman, MJ
    Koren, MJ
    Mensah, GA
    Ganau, A
    Devereux, RB
    HYPERTENSION, 1999, 33 (03) : 800 - 805
  • [5] Total arterial compliance estimated from the time constant of aortic pressure decay: the influence of downstream pressure
    Chemla, Denis
    Nitenberg, Alain
    FASEB JOURNAL, 2010, 24
  • [6] STROKE VOLUME FROM AORTIC PULSE PRESSURE
    GUIER, WH
    FRIESING.GC
    GOULDEN, DD
    ESTEY, E
    CIRCULATION, 1970, 42 (04) : I161 - &
  • [7] Ability of pulse power, esophageal Doppler, and arterial pulse pressure to estimate rapid changes in stroke volume in humans
    Marquez, Jose
    McCurry, Kenneth
    Severyn, Donald A.
    Pinsky, Michael R.
    CRITICAL CARE MEDICINE, 2008, 36 (11) : 3001 - 3007
  • [8] On the Estimation of Total Arterial Compliance from Aortic Pulse Wave Velocity
    Orestis Vardoulis
    Theodore G. Papaioannou
    Nikolaos Stergiopulos
    Annals of Biomedical Engineering, 2012, 40 : 2619 - 2626
  • [9] On the Estimation of Total Arterial Compliance from Aortic Pulse Wave Velocity
    Vardoulis, Orestis
    Papaioannou, Theodore G.
    Stergiopulos, Nikolaos
    ANNALS OF BIOMEDICAL ENGINEERING, 2012, 40 (12) : 2619 - 2626
  • [10] Pulse pressure vs. total arterial compliance as a marker of arterial health
    Haluska, BA
    Jeffriess, L
    Fathi, RB
    Mottram, PM
    Carlier, SG
    Marwick, TH
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2005, 35 (07) : 438 - 443