Total arterial compliance estimated by stroke volume to aortic pulse pressure ratio in humans

被引:349
|
作者
Chemla, D
Hébert, JL
Coirault, C
Zamani, K
Suard, I
Colin, P
Lecarpentier, Y
机构
[1] Ecole Polytech, Ensta, Loa, INSERM,U451, F-91125 Palaiseau, France
[2] Univ Paris 11, Hop Bicetre, Serv Physiol Cardioresp, F-94275 Le Kremlin Bicetre, France
[3] Hop Antoine Beclere, Serv Cardiol, F-92141 Clamart, France
关键词
heart period; ventricular-arterial coupling; wave reflection;
D O I
10.1152/ajpheart.1998.274.2.H500
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
On the basis of the windkessel model, the stroke volume-to-aortic pulse pressure ratio (SV/PP) has been proposed as an estimate of total arterial compliance, but recent studies have questioned this approximation. Aortic pressure was obtained at rest in 31 adults undergoing cardiac catheterization (47 +/- 14 yr): controls (n = 7), patients with dilated cardiomyopathy (n = 10), and patients with other cardiac diseases (n = 14). me calculated PP, mean aortic pressure (MAoP), heart period (T), SV (thermodilution cardiac output/ heart rate), total peripheral resistance (R), total arterial compliance estimated by area method (C-area), and the time constant of aortic pressure decay in diastole (RCarea). In the overall population (n = 31), there was no significant difference between SV/PP and C-area. SV/PP was linearly related to C-area (SV/PP = 0.99C(area) + 0.05; r = 0.98; P < 0,001); the slope and intercept did not differ fr om unity and zero, respectively. Similar results were obtained in the three subgroups. These results implied that PP/MAoP and T/RCarea, were proportionally related (T/RCarea = 1.18PP/MAoP - 0.07; r = 0.96; P < 0.001). We conclude that for humans at rest reliable estimate of C-area and 2) T normalized by the time constant of aortic pressure decay in diastole was proportionally related to PP/MAoP. This last relationship could be considered an aspect of the coupling between the left ventricle and its load.
引用
收藏
页码:H500 / H505
页数:6
相关论文
共 50 条
  • [21] The pulse pressure method for non-invasive evaluation of total arterial compliance
    Carlier, S
    Segers, P
    De Backer, T
    Stergiopoulos, N
    Thomas, J
    JOURNAL OF HYPERTENSION, 2000, 18 : S197 - S197
  • [22] In vitro evaluation of an extended pulse pressure method for the estimation of total arterial compliance
    Segers, P
    Coomans, I
    Verdonck, P
    Stergiopulos, N
    COMPUTERS IN CARDIOLOGY 1996, 1996, : 153 - 156
  • [23] A Noninvasive Smartphone Assessment of Aortic Arch Pulse Wave Velocity and Total Arterial Compliance
    Niroumandi, Soha
    Rinderknecht, Derek
    Bilgi, Coskun
    Wolfson, Aaron
    Vaidya, Ajay
    King, Kevin S.
    Pahlevan, Niema M.
    CIRCULATION, 2023, 148
  • [24] Total arterial compliance, estimated by a novel method, is better related to left ventricular mass compared to aortic pulse wave velocity: The SAFAR study
    Papaioannou, Theodore G.
    Protogerou, Athanase D.
    Argyris, Antonis
    Aissopou, Evangelia
    Georgiopoulos, George
    Nasothimiou, Efthimia
    Tountas, Christos
    Sfikakis, Petros P.
    Stergiopulos, Nikolaos
    Tousoulis, Dimitrios
    CLINICAL AND EXPERIMENTAL HYPERTENSION, 2017, 39 (03) : 271 - 276
  • [25] TOTAL SYSTEMIC VASCULAR COMPLIANCE MEASURED AS INCREMENTAL VOLUME-PRESSURE RATIO
    SHOUKAS, AA
    SAGAWA, K
    CIRCULATION RESEARCH, 1971, 28 (02) : 277 - &
  • [26] THE ARTERIAL PRESSURE AND PULSE WITH AORTIC STENOSIS
    MCDONALD, L
    SHANKS, J
    SMITH, W
    BRITISH HEART JOURNAL, 1956, 18 (04): : 568 - 568
  • [27] The pulse pressure-to-stroke volume ratio is a better predictor of risk than pulse pressure alone in hypertension
    Fagard, R
    Pardaens, K
    Staessen, J
    JOURNAL OF HYPERTENSION, 2000, 18 : S20 - S20
  • [28] A questionable association of stroke volume and arterial pulse pressure under gravitational stress
    Cote, Anita T.
    Phillips, Aaron A.
    Bredin, Shannon S. D.
    Warburton, Darren E. R.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2012, 72 (03): : 708 - 712
  • [29] Evaluation of stroke volume via arterial pulse pressure waveforms in neonatal lambs
    Kappler, S
    Milstein, JM
    Moon-Grady, AJ
    Bennett, SH
    BIOLOGY OF THE NEONATE, 2004, 86 (03): : 184 - 194
  • [30] A questionable association of stroke volume and arterial pulse pressure under gravitational stress
    Cote, Anita T.
    Bredin, Shannon S. D.
    Warburton, Darren E. R.
    FASEB JOURNAL, 2010, 24