Pulse Pressure Method and the Area Method for the Estimation of Total Arterial Compliance in Dogs: Sensitivity to Wave Reflection Intensity

被引:0
|
作者
Segers, Patrick
Verdonck, Pascal
Deryck, Yvon
Brimioulle, Serge
Naeije, Robert
Carlier, Stephane
Stergiopulos, Nikos
机构
[1] Hydraulics Laboratory, IBITECH, University of Gent, Sint-Pietersnieuwstraat 41, 9000 Gent, Belgium
[2] Cardiac Anesthesia, University Hospital of Gent, De Pintelaan 185, 9000 Gent, Belgium
[3] Lab. Cardiovasc. and Resp. Physiol., Free University of Brussels, Brussels, Belgium
[4] Cleveland Clinic Foundation, Cleveland, OH, United States
[5] Biomedical Engineering Laboratory, EPFL, Swiss Fed. Institute of Technology, Lausanne, Switzerland
[6] Hydraulics Laboratory, Institute Biomedical Technology, University of Gent, Sint-Pietersnieuwstraat 41, B-9000 Gent, Belgium
来源
关键词
This research is funded by a specialization grant of the Flemish Institute for the Promotion of the Scientific-Technological Research in Industry (IWT 943065—IWT 960250); a concerted action program of the University of Gent; supported by the Flemish Government (GOA 95003); and the Fonds de la Recherche Scientifique Medicale (Grant No. 3.4537.91). Dr. Carlier was the recipient of a grant from NATO and the Belgian American Educational Foundation;
D O I
暂无
中图分类号
学科分类号
摘要
16
引用
下载
收藏
页码:480 / 485
相关论文
共 50 条
  • [21] Contribution of wave reflection and arterial stiffness to central pulse pressure in women
    Cecelja, M.
    McNeill, K.
    Jiang, B.
    Kato, B.
    Spector, T.
    Chowienczyk, P.
    JOURNAL OF HUMAN HYPERTENSION, 2008, 22 (10) : 719 - 720
  • [22] BASAL NO PRODUCTION IS ASSOCIATED WITH ARTERIAL WAVE REFLECTION AND CENTRAL PULSE PRESSURE
    Schneider, M. R.
    Ott, C.
    Raff, U.
    Ritt, M.
    Schmieder, R. E.
    JOURNAL OF HYPERTENSION, 2009, 27 : S339 - S339
  • [23] A METHOD FOR RECORDING THE ARTERIAL PRESSURE PULSE AND BLOOD PRESSURE IN MAN
    PETERSON, LH
    DRIPPS, RD
    RISMAN, GC
    AMERICAN HEART JOURNAL, 1949, 37 (05) : 771 - 782
  • [24] Total arterial compliance, estimated by a novel method, is better related to left ventricular mass compared to aortic pulse wave velocity: The SAFAR study
    Papaioannou, Theodore G.
    Protogerou, Athanase D.
    Argyris, Antonis
    Aissopou, Evangelia
    Georgiopoulos, George
    Nasothimiou, Efthimia
    Tountas, Christos
    Sfikakis, Petros P.
    Stergiopulos, Nikolaos
    Tousoulis, Dimitrios
    CLINICAL AND EXPERIMENTAL HYPERTENSION, 2017, 39 (03) : 271 - 276
  • [25] Pulse wave velocity, total arterial compliance, and cardiac structure and function in late life
    Teramoto, K.
    Cheng, S.
    Claggett, B.
    Solomon, S.
    Heiss, G.
    Tanaka, H.
    Matsushita, K.
    Shah, A.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1325 - 1325
  • [26] A Noninvasive Smartphone Assessment of Aortic Arch Pulse Wave Velocity and Total Arterial Compliance
    Niroumandi, Soha
    Rinderknecht, Derek
    Bilgi, Coskun
    Wolfson, Aaron
    Vaidya, Ajay
    King, Kevin S.
    Pahlevan, Niema M.
    CIRCULATION, 2023, 148
  • [27] Metrological Characterization of a Method for Blood Pressure Estimation Based on Arterial Lumen Area Model
    Koohi, Iraj
    Batkin, Izmail
    Groza, Voicu Z.
    Shirmohammadi, Shervin
    Dajani, Hilmi R.
    Ahmad, Saif
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (04) : 734 - 745
  • [28] Prediction of all-cause mortality in the elderly using a novel method for the estimation of total arterial compliance
    Papaioannou, T. G.
    Protogerou, A. D.
    Stergiopoulos, N.
    Vardoulis, O.
    Safar, M.
    Blacher, J.
    Stefanadis, C.
    ARCHIVES OF HELLENIC MEDICINE, 2014, 31 (06): : 725 - 734
  • [29] CAROTID ARTERIAL PRESSURE PULSE BY DIRECT METHOD IN HORSE
    SENTA, T
    JAPANESE JOURNAL OF VETERINARY SCIENCE, 1970, 32 : 198 - &
  • [30] Estimation of laboratory wave reflection by a transfer function method
    Zhu, ST
    Chwang, AT
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 2001, 127 (03): : 300 - 304